1 of 1

Bently Nevada 167699-02 1900/65A Operator Interface

Bently Nevada 167699-02 1900/65A Operator Interface

Only 2 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 167699-02

  • Country of origin:United States

  • Product Type: Operator Interfaces

  • Payment: T/T, Western Union

  • Weight: 320g

  • Dimensions: 250 x 180 x 120 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed specifically for local machinery visualization, the Bently Nevada 167699-02 serves as the dedicated operator interface and display module for the 1900/65A General Purpose Equipment Monitor. This module acts as the primary local physical interface, allowing maintenance teams and plant operators to view real-time machinery health data, vibration profiles, and alarm metrics directly at the equipment skid. Built with industrial-grade resilience, it interfaces directly with the main monitor unit to provide high-clarity readout diagnostics without requiring secondary control system workstations.

Features

  • Provides continuous, local visualization of configured channel values, status indicators, and active system alerts.
  • Engineered specifically for plug-and-play integration with the Bently Nevada 1900/65A monitor series.
  • Clear panel-mount layout optimized for high-visibility reading in challenging plant environments.
  • Constructed to withstand the thermal and physical demands of cabinet and field-enclosure installations.

Applications

  • Local monitoring stations for critical pumps, industrial fans, and air blowers.
  • Skid-mounted visualization systems for reciprocating compressors and small steam turbines.
  • Balance-of-Plant (BOP) machinery integration across power generation and petrochemical sites.

Technical Specifications

Specification Parameter Value / Detail
Manufacturer Bently Nevada (Baker Hughes)
Part Number / SKU 167699-02
Device Type Operator Interface / Display Module
Compatibility Bently Nevada 1900/65A General Purpose Equipment Monitor
Country of Origin United States
Shipping Weight (Calculated) 3.0 kg
Package Dimensions (Calculated) 250 x 180 x 120 mm

Empirical Engineering Insights

Alternative Models & Compatibility: The 167699-02 is the dedicated display interface designed exclusively for the 1900/65A monitor series. Ensure your main base unit firmware matches the revision level of the replacement display module to prevent channel mapping offset issues during initialization.

Application Pitfalls & Engineering Notes: When mounting this operator interface inside high-vibration control cabinets or near rotating skids, ensure the enclosure uses adequate isolation dampeners. Persistent structural resonance can lead to fatigue on the internal ribbon cable connections, causing visual flickering or connection dropouts.

Commissioning & Wiring Tips: Always fully isolate the main 1900/65A monitor chassis before plugging or unplugging the display interface cable. Hot-swapping the display unit runs the risk of inducing electrical transients on the communication bus, which can fault the monitor logic or degrade the interface transceiver components.

Installation Guidelines

CRITICAL WARNING

Ensure all main power supplies connected to the 1900/65A monitor assembly are fully de-energized and locked out before attempting to install, connect, or service the operator interface. Static-discharge mitigation practices must be observed throughout physical installation to protect internal microprocessor logic.

1

Prepare the panel cutout according to the mechanical specifications of the 1900/65A enclosure guidelines.

2

Mount the display panel securely to ensure the environmental seal achieves its intended protection rating against dust and moisture.

3

Route the interface cable away from high-voltage conduit runs to prevent electromagnetic interference from distorting the digital signals.

4

Power up the main monitor unit and verify that the startup routine correctly maps system configurations to the display screen.

Loading product navigation…

Can the 167699-02 display module be hot-swapped while the monitor is live?

No, hot-swapping is not recommended. Power down the 1900/65A monitor chassis completely before connecting or disconnecting the operator interface to avoid electrical transient damage.

Is the 167699-02 display interface compatible with monitor systems other than the 1900/65A?

This display module is specifically designed and configured to function as the dedicated local interface for the 1900/65A General Purpose Equipment Monitor series.

Does this operator interface require an external power supply?

No, the display interface draws its power directly from the main 1900/65A monitor unit via its dedicated connection cable.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...