1 of 1

Bently Nevada 176449-08 3500 Series Rod Position Monitor I/O Module

Bently Nevada 176449-08 3500 Series Rod Position Monitor I/O Module

Only 4 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 176449-08

  • Country of origin:United States

  • Product Type: Rod Position Monitor Modules

  • Payment: T/T, Western Union

  • Weight: 320g

  • Dimensions: 28.5 x 19.0 x 6.5 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

To track the exact dynamic displacement of piston rods in reciprocating compressors, the Bently Nevada 176449-08 functions as a highly specialized I/O module within the 3500 Machinery Protection System. This module interfaces directly with the 3500/72M Reciprocating Compressor Rod Position Monitor, processing signal inputs from proximity probes and seismic transducers to ensure precise tracking of rod runout and position. By offering internal termination capabilities, this unit simplifies cabinet wiring and eliminates the need for external termination blocks, directly improving signal integrity and reducing installation footprints in critical petrochemical and gas processing plants.

Features

  • Four-channel input capability supporting both Proximitor and seismic transducers.
  • Internal termination architecture to streamline cabinet design and lower point-to-point wiring risks.
  • Direct backplane communication for high-speed data transmission to the main 3500 system rack.
  • Designed for harsh industrial environments, ensuring continuous monitoring of critical reciprocating machinery.
  • Hot-swappable design allows replacement of the physical I/O card without shutting down the entire protection rack.

Applications

  • Reciprocating compressor rod runout and mean position tracking.
  • Crosshead vibration measurement in high-pressure process gas systems.
  • Continuous industrial machinery health monitoring and protective tripping loops.

Technical Specifications

Parameter Value / Specification
Manufacturer Bently Nevada (Baker Hughes)
Part Number 176449-08
Compatible Monitor Module 3500/72M Reciprocating Compressor Monitor
Termination Type Internal Termination
Input Channels 4 Channels (Proximitor / Seismic)
Power Consumption Host rack powered (nominal backplane draw)
Operating Temperature Range -30 to +65 Celsius
Storage Temperature Range -40 to +85 Celsius
Humidity Limits 95% non-condensing relative humidity
Country of Origin United States
Shipping Weight (Calculated) 3.0 kg (6.6 lbs)
Package Dimensions (Calculated) 28.5 x 19.0 x 6.5 cm

Connections and Interfaces

The internal termination card provides a series of dedicated terminal blocks designed for secure field-wire attachment. Below is the typical pinout configuration layout for the input channels:

Terminal Terminal Group Label Name Signal Assignment / Function
Channel 1 Block -24V Transducer Power Output (Channel 1)
SIG Signal Input (Channel 1)
COM Signal Common (Channel 1)
Channel 2 Block -24V Transducer Power Output (Channel 2)
SIG Signal Input (Channel 2)
COM Signal Common (Channel 2)
Channel 3 Block -24V Transducer Power Output (Channel 3)
SIG Signal Input (Channel 3)
COM Signal Common (Channel 3)
Channel 4 Block -24V Transducer Power Output (Channel 4)
SIG Signal Input (Channel 4)
COM Signal Common (Channel 4)
Chassis Ground SHLD Shield Terminal (Internal Ring Connection to Rack Ground)

Alternative Models & Compatibility

The 176449-08 is designed specifically for standard internal termination setups. It is not directly interchangeable with external termination (ET) versions (such as the 176449-01 through 176449-07 variations) unless you also replace the external terminal block and connection cables. Always verify the module suffix matched on the existing chassis slot card before installation to avoid channel mismatched configuration faults in the 3500/72M monitor.

Application Pitfalls & Engineering Notes

When utilizing this module for reciprocating rod runout measurements, ensure that the proximity probe target areas on the piston rods are completely free of surface scratches, mechanical runout, and electrical runout. Ground loops are a common source of signal distortion; transducer shields must be grounded only at the 3500 rack ground terminals on the 176449-08 I/O card and cut back and isolated at the machine junction box.

Commissioning & Wiring Tips

Use 3-wire shielded, twisted-pair cable for all transducer runs back to the I/O module. After installation, verify the DC gap voltage utilizing the 3500 Rack Configuration Software before commissioning. An incorrect transducer setting or a misaligned physical sensor gap will trigger a "NOT OK" channel status light on the front panel of the corresponding 3500/72M monitor card.

Installation Guidelines

CRITICAL WARNING

Always verify that the 3500 monitor rack is fully de-energized or the specific monitor channel has been bypassed and bypassed outputs are locked out before inserting or removing the I/O module. Direct hot-swapping under active process trip loops can cause catastrophic machinery shutdown signals to the Distributed Control System (DCS) or Safety Instrumented System (SIS).

1
Power down the immediate slot or verify that the 3500/72M monitor associated with the slot is in "Bypass" status.
2
Wear a grounded ESD wrist strap before handling the sensitive internal circuit board of the 176449-08 module.
3
Slide the I/O module into the rear slots of the 3500 chassis until the connector seating pins are securely in position.
4
Secure the integrated thumbscrews tightly to ensure continuous chassis grounding and physical retention.
Loading product navigation…

What is the primary difference between the 176449-08 and other 176449 sub-models?

The 176449-08 features internal termination, meaning field wiring connects directly to terminal blocks on the I/O module itself, whereas other dashes typically require external termination blocks and interface cables.

Can I use the 176449-08 I/O module with any 3500 series monitor card?

No, the 176449-08 is specifically designed to function with the 3500/72M Reciprocating Compressor Rod Position Monitor card and cannot be used with standard vibration or keyphasor cards.

What are the common causes for a channel 'Not OK' status on this module?

This status typically points to field transducer wiring issues, such as a shorted or open circuit, incorrect DC gap voltage adjustment on the proximity probe, or a configuration mismatch in the software.

How should shield wiring be handled on the 176449-08?

Transducer shields must be landed on the dedicated SHLD terminals on the 176449-08 block. Ensure they are isolated and floated at the sensor/machine junction box to prevent ground loop noise.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...