What Is SCADA? Supervisory Control Without Replacing the PLC
SCADA sits above PLCs and RTUs: it acquires field data, alarms operators, and issues supervisory commands across plants and remote assets—without replacing local deterministic control.

Providing reliable eddy current measurement for critical machinery protection, the Bently Nevada 330101-00-15-20-02-CN serves as a non-contact displacement sensor within the 3300 XL 8 mm series. Designed for high-frequency vibration and position monitoring, this metric probe converts shaft displacement into highly linear voltage signals when paired with a compatible 3300 XL Proximitor Sensor. The probe configuration features a 0.0-inch unthreaded length, a 1.5-inch overall case length, and a 2.0-meter total cable length ending in a miniature coaxial ClickLoc connector, certified with country-specific CN agency approvals for explosive atmospheres.
| Option Code | Parameter Description | Selected Value |
|---|---|---|
| 330101 | Probe Model Type | 3300 XL 8 mm Proximity Probe, Metric (M10 x 1 Thread) |
| 00 | Unthreaded Length | 0.0 in (0 mm) |
| 15 | Overall Case Length | 1.5 in (38 mm) |
| 20 | Total Cable Length | 2.0 meters (6.6 feet) |
| 02 | Connector and Cable Type | Miniature coaxial ClickLoc connector, standard cable |
| CN | Agency Approvals | Country-specific approvals (CN variant) |
| Manufacturer | Bently Nevada | ||
| Probe Series | 3300 XL 8 mm | ||
| Thread Size | M10 x 1 (Metric) | ||
| Scale Factor | 7.87 V/mm (200 mV/mil) when combined with compatible Proximitor | ||
| Linear Range | 2.0 mm (80 mils) starting at 0.25 mm (10 mils) from the face | ||
| Operating Temperature Range | Connector Material | Gold-plated brass with Ryton insulator | |
| Minimum Bend Radius | 25.4 mm (1.0 in) for standard cable | ||
| Country of Origin | U.S.A. | ||
| Net Weight | 0.323 kg (0.71 lbs) | ||
| Shipping Weight (Calculated) | 1.500 kg (3.30 lbs) |
This 2.0-meter probe is engineered for systems configured for total lengths of either 5.0 meters or 9.0 meters. To operate within calibration specs, a 5.0-meter system requires a 3.0-meter extension cable, whereas a 9.0-meter system requires a 7.0-meter extension cable. Under no circumstances should probe cables and extension cables of differing system lengths (e.g., 5.0m extension mixed with 9.0m Proximitor) be cross-matched, as this will result in severe scale factor errors.
When threading the M10 case into bracket mounts, ensure there is a minimum target clearance of 16 mm (twice the probe diameter) from adjacent metallic objects to prevent side-view cross-talk. Ground loops are a common source of industrial noise in proximity systems; ensure the coaxial connector connection is insulated from machine ground inside the junction box using the supplied connector protector sleeves.
Always verify the physical mechanical gap using a feeler gauge or a digital voltmeter reading raw bias voltage from the Proximitor prior to final locknut tightening. Standard gap voltage should read approximately -10 VDC when centered in the linear range on a standard 4140 steel target.
Mount the bracket securely to the machine casing or internal structural member, ensuring zero deflection under high-vibration conditions.
Thread the M10 sensor body into the mounting bracket until the probe tip lightly touches the target shaft, then back it out to establish the required mechanical offset gap.
Tighten the locknuts to the specified torque. Connect the 2.0-meter probe cable to the extension cable, ensuring the ClickLoc connection is fully snapped into place.
Apply protective silicone tape over the connector assembly to seal out lube oils and environmental moisture.
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Color pattern |
Silver
Blue
|
| Country of origin |
United States
|