Derivative Action in PID Control Without Noise Problems
Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.
Manufacturer: Bently Nevada
Product No.: 330101-00-20-10-02-05
Country of origin:United States
Product Type: 3300 XL 8 mm Proximity Probe
Barcode: 8537101190
Payment: T/T, Western Union
Weight: 140g
Dimensions: 45 mm x 95 mm x 95 mm (H x W x D)
Shipping port: Xiamen
Warranty: 12 months
Option 00 (0.0 in unthreaded), Option 20 (2.0 in case), Option 10 (1.0 m total length), and Option 02 (Miniature ClickLoc, standard cable) specify this 330101-00-20-10-02-05 configuration of the 3300 XL 8 mm Proximity Probe. This non-contact, eddy-current transducer is a foundational component of the 3300 XL 8 mm monitoring system, designed for precise displacement measurement in industrial rotating machinery.
The 330101 probe features a 3/8-24 UNF thread and is an unarmored configuration. It is engineered to pair specifically with the 3300 XL Proximitor sensor and extension cable, maintaining system performance across a broad temperature range. This unit provides the necessary reliability for continuous monitoring of shaft vibration and axial position in turbines, compressors, pumps, and fans.
| Option | Code on This SKU | Description |
|---|---|---|
| Orderable Part Number | 330101-00-20-10-02-05 | 3300 XL 8 mm Proximity Probe, 3/8-24 UNF |
| A - Unthreaded Length | 00 | 0.0 in (fully threaded) |
| B - Case Length | 20 | 2.0 in |
| C - Total Length | 10 | 1.0 m |
| D - Connector/Cable | 02 | Miniature ClickLoc, standard cable |
| E - Agency Approval | 05 | CSA, ATEX, IECEx Approvals |
| Parameter | Specification |
|---|---|
| Manufacturer | Bently Nevada |
| Part Number | 330101-00-20-10-02-05 |
| Probe Diameter | 8 mm |
| Thread Size | 3/8-24 UNF-2A |
| Case Material | AISI 303/304 Stainless Steel |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Cable Type | 75 Ohm triaxial, FEP insulated (standard) |
| Connector | Miniature ClickLoc coaxial |
| Operating Temperature | -51 degC to +177 degC |
| Max Connector Torque | 0.565 Nm |
| Max Case Torque | 11.2 Nm |
Ensure the probe is gapped according to system calibration requirements (typically 1.27 mm). Use the recommended 3300 XL mounting brackets to secure the probe, ensuring that mounting screws are tightened to appropriate torque specifications. For hazardous area installations, adhere to local regulations regarding intrinsic safety barriers and cable routing. Keep connectors clean and free of moisture or oil contamination during installation; use the included silicone tape or appropriate protectors if the connection is exposed to industrial environments.
Global Express Shipping
Returns & Warranty



Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
United States
|