Bently Nevada

Bently Nevada 330130-080-12-RU 3300 XL Standard Extension Cable

SKU 330130-080-12-RU

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada

  • Product No.: 330130-080-12-RU

  • Country of origin:United States

  • Product Type: 3300 XL Standard Extension Cable

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 140g

  • Dimensions: 45 mm x 95 mm x 95 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The 330130-080-12-RU is a 3300 XL standard extension cable designed for integration within 3300 XL 8 mm proximity transducer systems. This specific configuration features an 8.0 meter cable length (Option 080) and utilizes FluidLoc cable with connector protector (Option 12), ensuring environmental protection and durability in critical rotating machinery monitoring environments. The RU suffix denotes the standard unit package for the 3300 XL system.

This extension cable serves as a key component in a complete 3300 XL transducer system, which consists of an 8 mm probe, the extension cable, and a Proximitor sensor. Proper installation requires that the combined length of the probe and extension cable equals the calibrated length of the Proximitor sensor. The ClickLoc connectors provide a secure, low-resistance connection, while the FluidLoc cable construction inhibits fluid ingress through the cable jacket, making it suitable for applications where exposure to liquids or oils may occur.

Features

  • Option 080: 8.0 meters (26.2 feet) cable length.
  • Option 12: FluidLoc cable with connector protector for enhanced environmental resistance and protection.
  • ClickLoc Connectors: Miniature coaxial connectors designed for reliable signal integrity and easy installation.
  • System Compatibility: Compatible with 3300 XL 8 mm proximity probes and 3300 XL Proximitor sensors.
  • Standardized Performance: Engineered to meet the strict impedance requirements of 3300 XL monitoring chains.

Applications

  • Turbine and compressor shaft vibration monitoring
  • Rotor axial position measurement
  • Critical rotating machinery protection
  • Industrial environments requiring fluid-resistant cabling

Ordering Information

Option Code on This SKU Description
Orderable Part Number 330130-080-12-RU 3300 XL Standard Extension Cable
A - Cable Length 080 8.0 meters (26.2 feet)
B - Cable Type/Connector 12 FluidLoc cable with connector protector
C - Agency Approval RU Standard (Not required/No specific hazardous area)

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada (Baker Hughes)
Part Number 330130-080-12-RU
Cable Length 8.0 meters (26.2 feet)
Cable Type FluidLoc
Connector Type ClickLoc with connector protector
Operating Temperature -52 degC to +177 degC
Storage Temperature -52 degC to +177 degC

Installation Guidelines

Ensure that the extension cable is routed away from high-voltage cables to prevent electromagnetic interference. When connecting the probe and extension cable, use the provided connector protectors to ensure a robust environmental seal. Tighten connectors to the recommended torque specifications to maintain signal integrity. Verify that the total length of the probe and extension cable matches the requirements of the paired Proximitor sensor before system initialization.

Compliance and Certifications

Complies with standard Bently Nevada 3300 XL system specifications for electromagnetic compatibility and hazardous area requirements (verify local site regulations for specific hazardous zone installations).

FAQ

What does the 12 option code mean for this 330130 cable?

The 12 option specifies a FluidLoc cable with an integrated connector protector, providing enhanced resistance against fluid ingress and environmental damage at the connector interface.

Can I use this 8.0 meter extension cable with any Proximitor sensor?

No, the 3300 XL system is calibrated based on a specific total system length. This 8.0 meter extension cable must be paired with a probe and a Proximitor sensor that are calibrated for the same total length.

Is this cable armored?

No, this SKU (option 12) is a FluidLoc cable, not an armored cable. If your application requires physical protection against abrasion, consider an armored variant.

What temperature range is this extension cable rated for?

The standard 3300 XL extension cable is rated for an operating and storage temperature range of -52 degC to +177 degC.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330130-080-12-RU 3300 XL Standard Extension Cable

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.