Designed specifically for industrial turbomachinery protection, the Bently Nevada 330703-000-060-10-11-00 provides high-accuracy non-contact shaft displacement and vibration measurement. This 3300 XL 11 mm Proximity Probe is engineered to withstand harsh, high-pressure environments, using specialized materials and construction to deliver long-term calibration stability in critical machine monitoring systems.
| Option Code | Selected Configuration Value | Description |
|---|---|---|
| 000 | Unthreaded Length | 00 mm |
| 060 | Overall Case Length | 60 mm |
| 10 | Total Length | 1.0 meter (3.3 feet) |
| 11 | Connector / Cable Type | Miniature coaxial ClickLoc connector with protector, FluidLoc cable |
| 00 | Agency Approvals | Not required |
| Parameter | Specification Value |
|---|---|
| Probe Diameter | 11 mm |
| Linear Range | 4.0 mm (160 mils) nominal |
| System Scale Factor | 3.93 V/mm (100 mV/mil) when paired with 3300 XL 11mm Proximitor |
| Operating Temperature | -51 to 177 degC (-60 to 351 degF) |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Probe Case Material | AISI 304 stainless steel (SST) |
| Cable Impedance & Type | 75 ohm triaxial, fluoroethylene propylene (FEP) insulated |
| Connector System | Miniature coaxial ClickLoc with protective sleeve |
| Manufacturer | Bently Nevada (Baker Hughes) |
| Country of Origin | United States |
| Shipping Weight (Calculated) | 1.0 kg |
| Package Dimensions (Calculated) | 250 mm x 200 mm x 50 mm |
| Connection Element | Function / Circuit Assignment |
|---|---|
| Coaxial Center Pin | High-frequency RF signal path (dynamic measurement return) |
| Coaxial Outer Shield | Common ground return and electromagnetic noise shielding |
| Connector Protector | Environmental moisture and mechanical locking shield |
The 11 mm proximity probe system has a larger linear range (4.0 mm) compared to standard 8 mm probes (2.0 mm). Always match this probe with a dedicated 3300 XL 11 mm Proximitor Sensor. Intermixing an 11 mm probe with an 8 mm Proximitor sensor will cause extreme scale factor errors and render the displacement readings inaccurate.
The FluidLoc cable specification (Option 11) is critical for installations where the machine case operates under oil mist or slight pressure differential. Non-FluidLoc cables can allow oil to bypass internal barriers via capillary action inside the cable jacket, resulting in contamination of the external junction box over long operational intervals.
During initial commissioning, avoid over-torquing the ClickLoc coaxial connection. Hand-tighten until a positive click is felt, then slide the connector protector sleeve firmly over the joint. To prevent interference issues, ensure that the extension cable shield is single-point grounded at the monitor rack, and not grounded inside the local junction box.
CRITICAL WARNING
Isolate and de-energize the rotating machinery before beginning installation. Ensure zero electrical potential on any adjoining sensor circuits. Never let the probe tip make physical contact with the target face during shaft rotation, as this will immediately destroy the PPS sensor face.
Mounting Verification
Secure the unthreaded probe body into your specialized mounting sleeve or bracket, ensuring the face of the probe is fully parallel to the target shaft surface.
Mechanical Gap Setting
Carefully thread the probe inward. Use a voltmeter monitoring the Proximitor's terminal output (OUT and COM) to set the gap to the physical midpoint of the linear range (nominally -10 VDC output).
Securing Locknuts
Once the target electrical gap is achieved, secure the locknuts to prevent axial slip. Avoid exceeding the specified torque limits to preserve the housing threads.
Connecting ClickLoc Coax
Join the coaxial ClickLoc terminal to the extension cable and slide the protection sleeve over the union to secure against ingress.
Global Express Shipping
Returns & Warranty

Designed specifically for industrial turbomachinery protection, the Bently Nevada 330703-000-060-10-11-00 provides high-accuracy non-contact shaft displacement and vibration measurement. This 3300 XL 11 mm Proximity Probe is engineered to withstand harsh, high-pressure environments, using specialized materials and construction to deliver long-term calibration stability in critical machine monitoring systems.
| Option Code | Selected Configuration Value | Description |
|---|---|---|
| 000 | Unthreaded Length | 00 mm |
| 060 | Overall Case Length | 60 mm |
| 10 | Total Length | 1.0 meter (3.3 feet) |
| 11 | Connector / Cable Type | Miniature coaxial ClickLoc connector with protector, FluidLoc cable |
| 00 | Agency Approvals | Not required |
| Parameter | Specification Value |
|---|---|
| Probe Diameter | 11 mm |
| Linear Range | 4.0 mm (160 mils) nominal |
| System Scale Factor | 3.93 V/mm (100 mV/mil) when paired with 3300 XL 11mm Proximitor |
| Operating Temperature | -51 to 177 degC (-60 to 351 degF) |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Probe Case Material | AISI 304 stainless steel (SST) |
| Cable Impedance & Type | 75 ohm triaxial, fluoroethylene propylene (FEP) insulated |
| Connector System | Miniature coaxial ClickLoc with protective sleeve |
| Manufacturer | Bently Nevada (Baker Hughes) |
| Country of Origin | United States |
| Shipping Weight (Calculated) | 1.0 kg |
| Package Dimensions (Calculated) | 250 mm x 200 mm x 50 mm |
| Connection Element | Function / Circuit Assignment |
|---|---|
| Coaxial Center Pin | High-frequency RF signal path (dynamic measurement return) |
| Coaxial Outer Shield | Common ground return and electromagnetic noise shielding |
| Connector Protector | Environmental moisture and mechanical locking shield |
The 11 mm proximity probe system has a larger linear range (4.0 mm) compared to standard 8 mm probes (2.0 mm). Always match this probe with a dedicated 3300 XL 11 mm Proximitor Sensor. Intermixing an 11 mm probe with an 8 mm Proximitor sensor will cause extreme scale factor errors and render the displacement readings inaccurate.
The FluidLoc cable specification (Option 11) is critical for installations where the machine case operates under oil mist or slight pressure differential. Non-FluidLoc cables can allow oil to bypass internal barriers via capillary action inside the cable jacket, resulting in contamination of the external junction box over long operational intervals.
During initial commissioning, avoid over-torquing the ClickLoc coaxial connection. Hand-tighten until a positive click is felt, then slide the connector protector sleeve firmly over the joint. To prevent interference issues, ensure that the extension cable shield is single-point grounded at the monitor rack, and not grounded inside the local junction box.
CRITICAL WARNING
Isolate and de-energize the rotating machinery before beginning installation. Ensure zero electrical potential on any adjoining sensor circuits. Never let the probe tip make physical contact with the target face during shaft rotation, as this will immediately destroy the PPS sensor face.
Mounting Verification
Secure the unthreaded probe body into your specialized mounting sleeve or bracket, ensuring the face of the probe is fully parallel to the target shaft surface.
Mechanical Gap Setting
Carefully thread the probe inward. Use a voltmeter monitoring the Proximitor's terminal output (OUT and COM) to set the gap to the physical midpoint of the linear range (nominally -10 VDC output).
Securing Locknuts
Once the target electrical gap is achieved, secure the locknuts to prevent axial slip. Avoid exceeding the specified torque limits to preserve the housing threads.
Connecting ClickLoc Coax
Join the coaxial ClickLoc terminal to the extension cable and slide the protection sleeve over the union to secure against ingress.
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
United States
|