Bently Nevada

Bently Nevada 330703-000-100-10-11-05 3300 XL 11 mm Proximity Probe

SKU 330703-000-100-10-11-05

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada
  • Product No.: 330703-000-100-10-11-05
  • Origin United States
  • Product Type: 3300 XL 11 mm Proximity Probe
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 0.18 kg
  • Dimensions: 50 mm x 100 mm x 100 mm (H x W x D)
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330703-000-100-10-11-05 3300 XL 11 mm Proximity Probe

Quantity

Product Description

Description

330703-000-100-10-11-05 is an unarmored, metric-threaded 3300 XL 11 mm Proximity Probe configured with a M14 x 1.5 thread, 0 mm of unthreaded length, a 100 mm overall case length, a 1.0 meter total length FluidLoc cable, a miniature coaxial ClickLoc connector with an integrated connector protector, and Multiple Approvals.

This configuration incorporates a specialized FluidLoc cable (Option 11) which features an internal block designed to prevent lubrication oil or process fluids from migrating through the inside of the triaxial cable. In addition, the factory-installed connector protector seals the critical probe-to-extension cable junction against environmental contaminants, while the unarmored M14 x 1.5 case allows direct installation into standard machinery housings without the extra routing bulk or bend limits associated with stainless steel armor options.

Features

  • M14 x 1.5 metric threaded configuration (base model 330703) without stainless steel armor for direct installation in standard machinery casings.
  • Option 000 unthreaded length providing a fully threaded 0 mm unthreaded probe body to optimize case engagement.
  • Option 100 overall case length specifying a 100 mm long threaded stainless steel casing.
  • Option 10 total length indicating a 1.0 meter (3.3 feet) integrated triaxial probe cable.
  • Option 11 FluidLoc cable type designed with a internal block to halt moisture and oil migration inside the cable.
  • Miniature coaxial ClickLoc connector with an integrated connector protector to guard the connector junction against severe fluids.
  • Option 05 Multiple Approvals package certified for ATEX, IECEx, and CSA hazardous area installations.
  • Polyphenylene sulfide (PPS) probe tip bonded structurally to the AISI 304 stainless steel probe case.

Applications

  • Axial thrust position measurements on utility steam and gas turbines.
  • Ramp differential expansion measurements in large-scale power generation machinery.
  • Radial vibration and shaft position monitoring on fluid-film bearing systems.
  • Rod drop and rod position measurements in critical reciprocating compressors.
  • Tachometer and zero-speed sensing applications.
  • Phase reference (Keyphasor) signal generation for speed and phase tracking.

Ordering Information

Option Code on This SKU Description
Orderable Part Number 330703-000-100-10-11-05 3300 XL 11 mm Probe, M14 x 1.5 thread, without armor
A - Unthreaded Length Option 000 0 mm unthreaded length
B - Overall Case Length Option 100 100 mm overall case length
C - Total Length Option 10 1.0 meter (3.3 feet) total length
D - Connector and Cable-Type Option 11 Miniature coaxial ClickLoc connector with connector protector, FluidLoc cable
E - Agency Approval Option 05 Multiple Approvals (CSA, ATEX, IECEx)

Technical Specifications

Parameter Value
Manufacturer Bently Nevada (Baker Hughes)
Model/Part Number 330703-000-100-10-11-05
System Compatibility 3300 XL 11 mm Proximity Transducer System
Probe Thread Type M14 x 1.5 metric thread (unarmored)
Unthreaded Length 0 mm
Overall Case Length 100 mm
Total Probe Length 1.0 meter (3.3 feet)
Cable Type 75 ohm triaxial, FEP insulated FluidLoc cable (oil barrier)
Connector Miniature coaxial ClickLoc connector with factory-installed connector protector
Probe Tip Material Polyphenylene sulfide (PPS)
Probe Case Material AISI 304 stainless steel (SST)
Connector Material Gold-plated brass
Linear Range 4.0 mm (160 mils), starting at 0.5 mm (20 mils) from target (range 0.5 to 4.5 mm)
System Output Scale Factor 3.94 V/mm (100 mV/mil) +/-10% (when used with matching system components)
Recommended Gap Setting 2.5 mm (100 mils)
Deviation from Straight Line (DSL) Less than +/-0.10 mm (+/-4 mils) standard; less than +/-0.15 mm (+/-6 mils) over extended temperatures
Probe DC Resistance 5.9 +/- 0.5 ohms (typical at 1.0 m total length)
Maximum Thread Engagement 21 mm
Maximum Case Torque 63.3 N-m (560 in-lb) maximum rated; 21.1 N-m (187 in-lb) recommended
Operating and Storage Temperature -52 to +177 degC (-62 to +351 degF)
Relative Humidity Limit 100% condensing, non-submersible when connectors are protected
Damp Heat Testing Tested to IEC 68-2-3 damp heat standards
Tensile Strength (Maximum Rated) 330 N (75 lb) probe case to lead; 270 N (60 lb) probe lead to extension cable connector
Minimum Cable Bend Radius 25.4 mm (1.0 in)
Target Size (Flat Surface) 30.5 mm (1.2 in) minimum recommended diameter
Minimum Shaft Diameter 152 mm (6.0 in)

Installation Guidelines

  • Observe the maximum thread engagement limit of 21 mm for the M14 x 1.5 probe case to prevent binding or thread deformation during assembly.
  • Utilize the recommended installation torque of 21.1 N-m (187 in-lb) during mounting, and never exceed the maximum rated limit of 63.3 N-m (560 in-lb).
  • Ensure the target area on the observed machinery shaft has a flat surface diameter of at least 30.5 mm (1.2 in) and the overall shaft diameter is at least 152 mm (6.0 in).
  • Establish the initial physical gap setting of 2.5 mm (100 mils) from the target to operate within the linear center of the transducer calibration curve.
  • Do not expose the probe assembly to operating temperatures below -34 degC in systems requiring active pressure sealing to avoid degrading the Viton O-ring seal.
  • Maintain a continuous minimum cable bend radius of 25.4 mm (1.0 in) to prevent coaxial signal degradation or conductor wear.
  • Verify that the factory-installed connector protector is fully seated over the miniature coaxial ClickLoc junction to prevent oil or moisture entry.

Compliance and Certifications

  • ATEX/IECEx: Intrinsically Safe (Ex ia IIC T5...T1 Ga) and Non-Sparking/Increased Safety (Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc) when installed per Bently Nevada drawings.
  • North American (CSA): Class I, Zone 0, AEx/Ex ia IIC T5...T1 Ga; Class I, Division 2, Groups A, B, C, D; Class II, Groups E, F, G; Class III.
  • CE Mark: Compliant with European Community Directive 2014/30/EU (EMC Directive) and 2011/65/EU (RoHS Directive).
  • Functional Safety: SIL 2 capable (HFT=0), SIL 3 capable (HFT=1) when configured inside an appropriate safety-instrumented system.
  • Maritime: Compliant with marine classification standards for marine propulsion and offshore platforms.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What does the FluidLoc cable option on this probe do?
The FluidLoc cable (Option 11) is designed with an internal block that prevents oil, water, or other process fluids from leaking out of the machine through the inside of the triaxial cable.
What thread type does the 330703-000-100-10-11-05 probe have?
This probe features an M14 x 1.5 metric thread with an unarmored cable design (base model 330703).
What are the unthreaded and case length dimensions of this configuration?
This probe has an unthreaded length of 0 mm (fully threaded case, Option 000) and an overall case length of 100 mm (Option 100).
Is a connector protector included with this probe?
Yes, this configuration includes a factory-installed miniature coaxial ClickLoc connector with an integrated connector protector.
Reviews

330703-000-100-10-11-05

Stock & lead time on request

Call
1 of 3

Bently Nevada 330703-000-100-10-11-05 3300 XL 11 mm Proximity Probe

Only 2 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 330703-000-100-10-11-05

  • Country of origin:United States

  • Product Type: 3300 XL 11 mm Proximity Probe

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 180g

  • Dimensions: 50 mm x 100 mm x 100 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

330703-000-100-10-11-05 is an unarmored, metric-threaded 3300 XL 11 mm Proximity Probe configured with a M14 x 1.5 thread, 0 mm of unthreaded length, a 100 mm overall case length, a 1.0 meter total length FluidLoc cable, a miniature coaxial ClickLoc connector with an integrated connector protector, and Multiple Approvals.

This configuration incorporates a specialized FluidLoc cable (Option 11) which features an internal block designed to prevent lubrication oil or process fluids from migrating through the inside of the triaxial cable. In addition, the factory-installed connector protector seals the critical probe-to-extension cable junction against environmental contaminants, while the unarmored M14 x 1.5 case allows direct installation into standard machinery housings without the extra routing bulk or bend limits associated with stainless steel armor options.

Features

  • M14 x 1.5 metric threaded configuration (base model 330703) without stainless steel armor for direct installation in standard machinery casings.
  • Option 000 unthreaded length providing a fully threaded 0 mm unthreaded probe body to optimize case engagement.
  • Option 100 overall case length specifying a 100 mm long threaded stainless steel casing.
  • Option 10 total length indicating a 1.0 meter (3.3 feet) integrated triaxial probe cable.
  • Option 11 FluidLoc cable type designed with a internal block to halt moisture and oil migration inside the cable.
  • Miniature coaxial ClickLoc connector with an integrated connector protector to guard the connector junction against severe fluids.
  • Option 05 Multiple Approvals package certified for ATEX, IECEx, and CSA hazardous area installations.
  • Polyphenylene sulfide (PPS) probe tip bonded structurally to the AISI 304 stainless steel probe case.

Applications

  • Axial thrust position measurements on utility steam and gas turbines.
  • Ramp differential expansion measurements in large-scale power generation machinery.
  • Radial vibration and shaft position monitoring on fluid-film bearing systems.
  • Rod drop and rod position measurements in critical reciprocating compressors.
  • Tachometer and zero-speed sensing applications.
  • Phase reference (Keyphasor) signal generation for speed and phase tracking.

Ordering Information

Option Code on This SKU Description
Orderable Part Number 330703-000-100-10-11-05 3300 XL 11 mm Probe, M14 x 1.5 thread, without armor
A - Unthreaded Length Option 000 0 mm unthreaded length
B - Overall Case Length Option 100 100 mm overall case length
C - Total Length Option 10 1.0 meter (3.3 feet) total length
D - Connector and Cable-Type Option 11 Miniature coaxial ClickLoc connector with connector protector, FluidLoc cable
E - Agency Approval Option 05 Multiple Approvals (CSA, ATEX, IECEx)

Technical Specifications

Parameter Value
Manufacturer Bently Nevada (Baker Hughes)
Model/Part Number 330703-000-100-10-11-05
System Compatibility 3300 XL 11 mm Proximity Transducer System
Probe Thread Type M14 x 1.5 metric thread (unarmored)
Unthreaded Length 0 mm
Overall Case Length 100 mm
Total Probe Length 1.0 meter (3.3 feet)
Cable Type 75 ohm triaxial, FEP insulated FluidLoc cable (oil barrier)
Connector Miniature coaxial ClickLoc connector with factory-installed connector protector
Probe Tip Material Polyphenylene sulfide (PPS)
Probe Case Material AISI 304 stainless steel (SST)
Connector Material Gold-plated brass
Linear Range 4.0 mm (160 mils), starting at 0.5 mm (20 mils) from target (range 0.5 to 4.5 mm)
System Output Scale Factor 3.94 V/mm (100 mV/mil) +/-10% (when used with matching system components)
Recommended Gap Setting 2.5 mm (100 mils)
Deviation from Straight Line (DSL) Less than +/-0.10 mm (+/-4 mils) standard; less than +/-0.15 mm (+/-6 mils) over extended temperatures
Probe DC Resistance 5.9 +/- 0.5 ohms (typical at 1.0 m total length)
Maximum Thread Engagement 21 mm
Maximum Case Torque 63.3 N-m (560 in-lb) maximum rated; 21.1 N-m (187 in-lb) recommended
Operating and Storage Temperature -52 to +177 degC (-62 to +351 degF)
Relative Humidity Limit 100% condensing, non-submersible when connectors are protected
Damp Heat Testing Tested to IEC 68-2-3 damp heat standards
Tensile Strength (Maximum Rated) 330 N (75 lb) probe case to lead; 270 N (60 lb) probe lead to extension cable connector
Minimum Cable Bend Radius 25.4 mm (1.0 in)
Target Size (Flat Surface) 30.5 mm (1.2 in) minimum recommended diameter
Minimum Shaft Diameter 152 mm (6.0 in)

Installation Guidelines

  • Observe the maximum thread engagement limit of 21 mm for the M14 x 1.5 probe case to prevent binding or thread deformation during assembly.
  • Utilize the recommended installation torque of 21.1 N-m (187 in-lb) during mounting, and never exceed the maximum rated limit of 63.3 N-m (560 in-lb).
  • Ensure the target area on the observed machinery shaft has a flat surface diameter of at least 30.5 mm (1.2 in) and the overall shaft diameter is at least 152 mm (6.0 in).
  • Establish the initial physical gap setting of 2.5 mm (100 mils) from the target to operate within the linear center of the transducer calibration curve.
  • Do not expose the probe assembly to operating temperatures below -34 degC in systems requiring active pressure sealing to avoid degrading the Viton O-ring seal.
  • Maintain a continuous minimum cable bend radius of 25.4 mm (1.0 in) to prevent coaxial signal degradation or conductor wear.
  • Verify that the factory-installed connector protector is fully seated over the miniature coaxial ClickLoc junction to prevent oil or moisture entry.

Compliance and Certifications

  • ATEX/IECEx: Intrinsically Safe (Ex ia IIC T5...T1 Ga) and Non-Sparking/Increased Safety (Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc) when installed per Bently Nevada drawings.
  • North American (CSA): Class I, Zone 0, AEx/Ex ia IIC T5...T1 Ga; Class I, Division 2, Groups A, B, C, D; Class II, Groups E, F, G; Class III.
  • CE Mark: Compliant with European Community Directive 2014/30/EU (EMC Directive) and 2011/65/EU (RoHS Directive).
  • Functional Safety: SIL 2 capable (HFT=0), SIL 3 capable (HFT=1) when configured inside an appropriate safety-instrumented system.
  • Maritime: Compliant with marine classification standards for marine propulsion and offshore platforms.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330703-000-100-10-11-05 3300 XL 11 mm Proximity Probe

What does the FluidLoc cable option on this probe do?

The FluidLoc cable (Option 11) is designed with an internal block that prevents oil, water, or other process fluids from leaking out of the machine through the inside of the triaxial cable.

What thread type does the 330703-000-100-10-11-05 probe have?

This probe features an M14 x 1.5 metric thread with an unarmored cable design (base model 330703).

What are the unthreaded and case length dimensions of this configuration?

This probe has an unthreaded length of 0 mm (fully threaded case, Option 000) and an overall case length of 100 mm (Option 100).

Is a connector protector included with this probe?

Yes, this configuration includes a factory-installed miniature coaxial ClickLoc connector with an integrated connector protector.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Inside the PLC CPU: Scan Cycles, Memory, and Selection

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.