Bently Nevada

Bently Nevada 330730-080-01-05 3300 XL 11 mm Extension Cable

SKU 330730-080-01-05

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada

  • Product No.: 330730-080-01-05

  • Country of origin:United States

  • Product Type: 3300 XL 11 mm Extension Cable

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 180g

  • Dimensions: 50 mm x 100 mm x 100 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Option 080 (8.0 meters length) and Option 01 (armored coaxial cable) specify this 3300 XL 11 mm extension cable configuration — 330730-080-01-05. As a critical link in the proximity transducer chain, this 3300 XL 11 mm Extension Cable connects the 11 mm probe to a 3300 XL Proximitor sensor, facilitating continuous, non-contact measurement of radial vibration, axial position, and speed on large rotating machinery.

This configuration utilizes a 75 Ohm triaxial cable core insulated with fluoroethylene propylene (FEP) to protect signal integrity in high-temperature industrial environments. The added flexible stainless steel armor and FEP outer jacket shield the coaxial lines from mechanical abrasion, physical impact, and corrosive moisture or turbine lubricants found in industrial plants.

Features

  • Option 080 specifies an 8.0-meter (26.2-foot) physical cable length to satisfy precise system loop requirements.
  • Option 01 adds flexible AISI 302 stainless steel armor with an FEP outer jacket for robust mechanical shielding.
  • Option 05 designates multiple agency approvals for safe deployment in hazardous locations and classified areas.
  • Miniature coaxial ClickLoc connectors provide clean, tool-free locking interfaces between the probe lead and Proximitor sensor.
  • Gold-plated brass connector bodies resist corrosion and ensure reliable signal conduction over extended operating cycles.

Applications

This cable is used alongside 11 mm proximity probes on heavy industrial rotating equipment such as steam turbines, gas turbines, turbo-compressors, and generators. The extended physical range of 11 mm transducer systems is highly suited for thrust (axial) position monitoring, differential expansion measurements, and rod-drop calculations in reciprocating compressors where a wider linear range is necessary. The armored jacket makes this specific cable configuration optimal for routing across exposed open-air paths, conduit bends, and high-debris zones.

Ordering Information

Option Segment Selected Code Description / Meaning
Base Model 330730 3300 XL 11 mm Extension Cable
A: Cable Length Option 080 8.0 meters (26.2 feet)
B: Connector and Cable Option 01 Armored coaxial cable (flexible AISI 302 SST with FEP outer jacket)
C: Agency Approval Option 05 Multiple Approvals (CSA, ATEX, IECEx) for hazardous areas

Technical Specifications

Parameter Specification Value
Manufacturer Bently Nevada (Baker Hughes)
Part Number / Model 330730-080-01-05
System Compatibility 3300 XL 11 mm Proximity Transducer System
Cable Material 75 Ohm triaxial, fluoroethylene propylene (FEP) insulated
Armor Protection Flexible AISI 302 stainless steel armor with protective FEP outer jacket
Cable Impedance 75 Ohm
Cable Capacitance 69.9 pF/m (21.3 pF/ft) typical
Core Resistance (RCORE) 0.6 +/- 0.2 ohms
Jacket Resistance (RJACKET) 2.0 +/- 0.5 ohms
Minimum Bend Radius 25.4 mm (1.0 inch)
Tensile Strength (Maximum) 270 N (60 lbs) tension rating at probe lead to extension cable connection
Operating and Storage Temperature -52 degC to +177 degC (-62 degF to +351 degF)
Connector Construction Gold-plated brass ClickLoc coaxial connectors

Installation Guidelines

When installing the extension cable, observe the minimum bend radius limit of 25.4 mm (1.0 inch) to protect the internal triaxial conductors and outer armor from mechanical fatigue. Hand-tighten the ClickLoc coaxial connectors before applying final torque using connector-to-connector guidelines; do not exceed a maximum torque of 0.565 N-m. For wet or oil-exposed installations outside the machine casing, apply silicone self-fusing tape (Bently Nevada part number 03200006) to seal connection joints. Avoid using tape inside turbine housings where direct exposure to hot lubricating oil can degrade the adhesive structure.

Compliance and Certifications

This transducer component complies with major global industrial standards, including the European Union EMC Directive 2014/30/EU (tested to EN 61000-6-2 and EN 61000-6-4) and RoHS Directive 2011/65/EU. When combined with certified probes and Proximitor sensors under Option 05, the transducer system carries multiple international certifications for hazardous atmospheres, covering Class I Division 1 and 2, and Zone 0, 1, and 2 environments (ATEX, IECEx, and CSA).

FAQ

What does the 080 option signify for the 330730-080-01-05 extension cable?

The 080 option specifies a physical cable length of 8.0 meters (26.2 feet).

Does this cable include physical armoring?

Yes, the 01 option indicates the cable is equipped with flexible AISI 302 stainless steel armor and an FEP outer jacket.

What approvals are included with the 05 option?

The 05 option designates multiple agency approvals, which license the transducer components for hazardous locations under CSA, ATEX, and IECEx certifications.

What is the recommended minimum bend radius for this armored cable?

The minimum bend radius is 25.4 mm (1.0 inch), whether routing the armored or standard cable variant.

What is the temperature rating of the 330730 extension cable?

The cable is rated for an operating and storage temperature range of -52 degC to +177 degC (-62 degF to +351 degF).

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330730-080-01-05 3300 XL 11 mm Extension Cable

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.