1 of 3

Bently Nevada 3500/05-01-02-00-00-01 System Rack

Bently Nevada 3500/05-01-02-00-00-01 System Rack

Only 6 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 3500/05-01-02-00-00-01

  • Country of origin:United States

  • Product Type: System Rack

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 13600g

  • Dimensions: 482.60 mm x 265.94 mm x 349.25 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The 3500/05-01-02-00-00-01 is a full-size, 19-inch System Rack manufactured by Bently Nevada (a Baker Hughes business) designed as the foundational structural framework for the 3500 Series Machinery Protection System. This hardware serves as the physical chassis and high-speed backplane hub that houses all core 3500 series machinery vibration monitors, transient data interfaces, and system power supplies. The integrated digital backplane allows distinct instrumentation slots to seamlessly exchange real-time control data, while simultaneously supplying a highly filtered internal power distribution grid to each individual slide-in module.

The exact ordering configuration code 3500/05-01-02-00-00-01 details a 19-inch full-size structural chassis containing 14 available instrumentation slots (excluding the dedicated left-hand utility power and rack interface module positions). It features a Bulkhead Mount structural format option, meaning it is engineered to mount directly flat against a wall, structural bulkhead panel, or within a custom enclosure where traditional 19-inch EIA open-frame relay rails are unavailable. All underlying input/output field terminations, transducer loops, and backend I/O modules are fully accessible directly from the front panel interface in this layout option. This model contains European Compliance (CE) certifications and is standard production series hardware.

Features

  • Central high-speed communication backplane enabling real-time processing interaction between protection cards.
  • Full-size 19-inch instrumentation architecture offering 14 discrete, customizable module expansion slots.
  • Bulkhead mount design allowing flush vertical surface installation where traditional 19-inch cabinet rails are absent.
  • Front-access I/O capability ensuring field sensor loops and external terminations can be fully wired from the front.
  • Rigid industrial-grade structural metal build to damp ambient high-frequency vibration and shield against magnetic interference.
  • Full European Compliance (CE) approval rating factory-certified for reliable implementation across European industrial assets.

Applications

  • Primary localized equipment rack holding machinery protection cards for large utility steam and gas turbines.
  • Plant-wide central safety interlock and predictive maintenance monitoring hub on high-vibration compression trains.
  • Bulkhead-mounted field enclosures used inside harsh oil and gas refinery or petrochemical control rooms where rear access is blocked.

Option String Breakdown

Option Code Slot Selected Option Value Technical Detail
Model Number 3500/05 System Rack Product Series
A: Rack Size -01 19-inch Rack (14 usable module slots)
B: Mounting Options -02 Bulkhead Mount Option, Full-Size Rack format
C: Agency Approval Option -00 None (Standard safety area classification)
D: Reserved Option -00 None (Factory baseline configuration)
E: European Compliance -01 CE Approved (European Compliance certification label included)

Technical Specifications

Parameter Detail
Manufacturer Bently Nevada (Baker Hughes)
Part Variant ID 3500/05-01-02-00-00-01
Product Category Condition Monitoring System Chassis Rack
Total Available Slots 14 slots for standard monitors, plus 2 dedicated left positions for Power/RIM
Physical Mounting Profile Bulkhead surface integration with front-facing I/O wiring access
Overall Framework Width 482.60 mm (Standard 19-inch footprint)
Overall Framework Height 265.94 mm
Overall Framework Depth 349.25 mm
Average Component Weight Approximately 13.6 kg (30 lbs) to 20.4 kg (45 lbs) empty
Enclosure Material Base Heavy-gauge aluminum and structural sheet metal alloys
Ground Reference Target Dedicated copper ground lugs provided on the chassis grid

Connections/Interfaces

Structural Interface Function Assignment
Internal Bus Backplane High-density pin array distributing internal DC power and control logic between slots
Front I/O Panel Space Bulkhead configuration routing slide-in external field sensor termination blocks to the front
Chassis Ground Lug Heavy-duty copper stud point connecting the rack frame to structural earth safety grounds

Installation Guidelines

  • Bulkhead Surface Preparation: Verify the wall or structural panel can continuously support the weight of a fully populated 3500 rack (up to 45 lbs or 20.4 kg). Pre-drill mounting holes to match the exact template spacing provided in Bently Nevada installation manuals.
  • Front Access Clearances: Because this is a Bulkhead Mount (-02) chassis, both the primary monitor cards and their corresponding I/O modules install from the front. Maintain a minimum of 250 mm clearance in front of the rack face for cable bending radiuses, wiring trunking, and module removal.
  • Dedicated Utility Slot Rules: Remember that the far left slots are dedicated exclusively to the power supply modules (such as the 3500/15) and the Rack Interface Module (3500/22M). Standard machinery monitors cannot be forced into these utility slots.
  • Chassis Earth Ground Link: Connect a heavy-gauge copper grounding wire from the main chassis earth stud to the primary electrical ground grid of the control panel enclosure to block electrical noise and ensure instrumentation stability.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 3500/05-01-02-00-00-01 System Rack

Loading PDF, please wait…

What configuration is defined by the '-02' mounting option on this 3500/05 rack?

The '-02' mounting option designates a Bulkhead Mount framework. This layout allows the chassis to be mounted flat against walls or solid backplates, moving all I/O modules and transducer wire terminations to the front of the rack for easy access when rear space is unavailable.

Which specific modules must be placed in the far left positions of the 3500/05 chassis?

The rack power supply modules (such as the 3500/15) and the Rack Interface Module (RIM, such as the 3500/22M) are required to occupy the specialized far-left slot positions of the chassis.

Does this specific rack configuration include certifications for installation within the European Economic Area?

Yes. The final '01' suffix in the option string specifies European Compliance, meaning the rack structure is factory-certified and marked with the CE approval stamp for industrial noise and safety standards.

What is the mechanical risk of running a full-size 3500 system rack without connecting the dedicated heavy-duty chassis ground lug?

Leaving the chassis ground lug disconnected allows floating static charges, high-frequency radio frequency interference (RFI), and electromagnetic fields from nearby switching equipment or VFDs to couple into the backplane bus. This manifests as intermittent instrumentation noise, false 'NOT OK' sensor alarms, or unexpected trip commands.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States

Recently Viewed Products

Technical knowledge

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive