1 of 1

Bently Nevada 3500/25-02-01-CN 3500/25 Enhanced Keyphasor Module

Bently Nevada 3500/25-02-01-CN 3500/25 Enhanced Keyphasor Module

Only 4 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 3500/25-02-01-CN

  • Country of origin:United States

  • Product Type: Machinery Protection Modules

  • Payment: T/T, Western Union

  • Weight: 800g

  • Dimensions: 119.9 mm x 24.4 mm x 256.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The 3500/25 is a half-height, two-channel instrument rack component that processes raw sensor inputs to provide precise timing signals for the 3500 Series Machinery Protection System. This specialized enhanced keyphasor module transforms incoming waveforms from proximity probes or magnetic pickups into digital pulses aligned exactly with the alignment mark on a rotating shaft. By delivering accurate once-per-turn or multi-event-per-turn indicators, the unit enables adjacent monitoring cards and external diagnostic software to calculate rotational velocity, phase angles, and synchronized 1X vibration vectors.

The standard hardware framework accommodates up to four independent inputs during basic operating configurations, and scales up to eight input nodes when utilizing a paired layout arrangement across adjacent slots. For high-reliability environments necessitating Triple Modular Redundant (TMR) safety layers, two modules operate concurrently in parallel to supply a uninterrupted stream of primary and secondary synchronization pulses directly across the chassis backplane.

Features

  • Processes dual transducer source channels within a single half-height slot allocation.
  • Provides downward form, fit, and functional compatibility to directly replace legacy 125792-01 assemblies.
  • Translates multi-event pulse configurations into standard once-per-turn reference outputs.
  • Equipped with dual buffered outputs accessible on both the front panel and rear terminal frames.
  • Supports field-upgradeable firmware routines alongside native asset management metrics.

Applications

  • High-velocity steam turbine and industrial compressor phase tracking line architectures.
  • Synchronous machinery vibration vector diagnostics and rotative speed monitoring systems.
  • Triple Modular Redundant (TMR) safety-critical monitoring configurations within chemical process plants.

Ordering Information

Selection Code Description
3500/25 Enhanced Keyphasor Module Series 
-02 Number of Channels: Two half-height 2-channel Keyphasor cards (order for 4-Channels) 
-01 Type of I/O Module: I/O module with Internal Terminations 
-CN Agency Approval Option: CN (Specific verified regional or country designation placeholder) 

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada (A Baker Hughes Company) 
Country of Origin USA 
Power Consumption 3.2 Watts typical 
Input Signal Range (Nonisolated) +0.8 V to -21.0 V 
Input Signal Range (Isolated) +5 V to -11 V 
Input Impedance 21.8 kOhm minimum 
Speed/Frequency Input Range 1 to 1,200,000 cpm (0.017 to 20 kHz) 
Speed/Frequency Output Range 1 to 99,999 cpm (0.017 to 1667 Hz) 
Passive Magnetic Pickup RPM Limit Greater than 200 rpm (3.3 Hz) 
Auto Threshold Trigger Amplitude 2 Volts peak-to-peak minimum 
Manual Threshold Adjust Range 0 to -20 Vdc 
Hysteresis Adjustment Range 0.2 to 2.5 Volts 
Maximum Output Impedance 504 Ohm maximum buffered output impedance 
Transducer Power Supply -24 Vdc, 40 mA maximum per channel 
Operating Temperature (Standard I/O) -30 degC to +65 degC (-22 degF to +150 degF) 
Operating Temperature (Barrier I/O) 0 degC to +65 degC (32 degF to +150 degF) 
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF) 
Relative Humidity Limit 95%, non-condensing 
Main Module Dimensions (H x W x D) 119.9 mm x 24.4 mm x 256.5 mm (4.72 in x 0.96 in x 10.10 in) 
Main Module Weight 0.34 kg (0.76 lbs.) 
I/O Module Dimensions (H x W x D) 241.3 mm x 24.4 mm x 103.1 mm (9.50 in x 0.96 in x 4.06 in) 
I/O Module Weight 0.46 kg (1.01 lbs.) 

Connections/Interfaces

Component / Indicator Function / Routing
OK LED Front panel status indicator that flashes or goes dark when a internal module fault is present.
TX/RX LED Front panel communication indicator showing operational data exchange with the Rack Interface Module (RIM).
Coaxial Connectors Two independent buffered output ports positioned directly on the front panel faceplate.
Euro Style Connectors Rear-facing buffered synchronization line interfaces mounted on the specific I/O block.

Installation Guidelines

  • Rack Insertion Rules: Slide the half-height front card into any of the 14 available standard slot spaces using a specialized card adapter alignment tool.
  • Chassis Density Controls: Limit total system deployment to a maximum of two active main modules per single rack frame, separating them between top and bottom half-slot levels.
  • Electrostatic Discharge Protection: Personnel must connect a verified single-use grounding wrist strap to the rack chassis ground before manipulating interior logic boards.
  • Termination Restraints: Ensure that external termination blocks are never cross-connected into rear cards configured for internal termination architecture.

Compliance and Certifications

  • FCC Rules: Complies with Part 15 regulations regarding high-frequency emissions containment.
  • European EMC Directive: 2014/30/EU; enforcing compliance with EN 61000-6-2 and EN 61000-6-4 industrial benchmarks.
  • Low Voltage Directive: 2014/35/EU; certified via compliance testing under EN 61010-1 parameters.
  • Maritime Approvals: Formally certified under DNV GL classification rules alongside ABS Steel Vessels and Offshore Structures standards.
  • RoHS Directives: Certified under standard EU RoHS Directive 2011/65/EU and China RoHS frameworks.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 3500/25-02-01-CN 3500/25 Enhanced Keyphasor Module

What is the primary function of this module in a 3500 rack system?

The module processes raw pulses from proximity probes or magnetic pickups to create digital once-per-turn phase and speed signals used for machinery diagnostics.

Can an external termination block be connected to an internal termination I/O module configuration?

No. External termination blocks and their associated cabling cannot be utilized with I/O modules designated for internal termination layouts.

What are the standard ambient operating temperature constraints for this hardware component?

When paired with a non-barrier I/O option, the certified ambient operating range spans from -30 degC to +65 degC.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...