1 of 1

Bently Nevada 9571-02 Standard Interconnect Cable

Bently Nevada 9571-02 Standard Interconnect Cable

Only 6 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 9571-02

  • Country of origin:United States

  • Product Type: Standard Interconnect Cables

  • Payment: T/T, Western Union

  • Weight: 320g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Engineered to deliver high-integrity signal transmission within critical machinery protection architectures, the Bently Nevada 9571-02 facilitates low-noise connectivity between industrial transducers and monitoring systems. This heavy-duty cable features a 2-conductor twisted, shielded 22 AWG construction that actively minimizes electromagnetic interference (EMI) and cross-talk in harsh electromagnetic environments. Designed with a specialized 2-socket moisture-resistant female connector at one end and rugged terminal lugs at the other, this 2-foot cable ensures a highly secure electrical and mechanical interface for critical vibration monitoring points. It is built specifically for integration with local monitor racks, excluding use with the 21128 Velocity Transducer Housing.

Features

  • High-Noise Rejection: Twisted-pair configuration combined with an integrated shield drain wire isolates fragile transducer signals from plant EMI/RFI.
  • Rugged Termination: Equipped with a molded, moisture-resistant 2-socket female connector for reliable sensor-side sealing.
  • Secure Panel Interfacing: Pre-terminated with high-quality terminal lugs for direct, reliable installation onto barrier strips and monitor backplanes.
  • Precision Mechanics: Optimally sized 22 AWG conductors maintain electrical continuity and mechanical durability under structural vibration.
  • Short-Run Optimization: 2-foot minimum length design prevents excess cable slack, keeping control cabinets organized and free of inductive loops.

Applications

  • Machinery protection system loops (e.g., Bently Nevada 3500 and 1900 series monitors).
  • Prox probes and vibration sensor-to-junction box connections.
  • Balance-of-plant rotating machinery health monitoring.
  • Short-run internal cabinet and local structural transducer routing.

Technical Specifications Table

Parameter Specification Value
Manufacturer Bently Nevada
Part Number / SKU 9571-02
Cable Type Standard Interconnect Cable (2-Conductor Twisted, Shielded)
Conductor Gauge 22 AWG
Cable Length 2 feet (0.6 meters)
Connector End A 2-socket moisture-resistant female connector
Connector End B Terminal Lugs
Country of Origin United States (USA)
Net Physical Weight 0.11 kg (0.24 lbs) (Calculated)
Shipping Weight (Calculated) 2.0 kg (including packaging and protective spooling)

Connections and Interfaces

Connector Pin / Terminal Function / Signal Assignment
Socket Pin A Signal High / Dynamic Signal (+)
Socket Pin B Signal Common / Return (-)
Terminal Lugs Termination points for terminal block connections at monitor panel
Outer Shield / Drain Grounding shield (MUST terminate only at the monitor common ground)

Empirical Engineering Insights

Alternative Models & Compatibility

The 9571-02 interconnect cable is optimized for standard industrial monitor configurations. It is crucial to note that this specific standard cable is not compatible with the Bently Nevada 21128 Velocity Transducer Housing due to diameter clearances and physical connection constraints. If your plant utilizes the 21128 housing, you must source a specialized splash-resistant or armored cable assembly built specifically for that enclosure profile.

Application Pitfalls & Engineering Notes

Because this is a non-armored variant, care must be taken during routing. Avoid routing the 9571-02 directly parallel to high-voltage AC motor lines or variable frequency drive (VFD) output cables. Lack of mechanical armor means this cable should always be housed within dedicated, grounded conduit or cable trays when routed outside of localized, enclosed instrument cabinets to prevent physical shearing or crushing.

Commissioning & Wiring Tips

To ensure the integrity of high-frequency vibration diagnostics, always terminate the cable's shield drain wire at the monitor rack ground. Never ground the shield at both ends; double-grounding creates ground loops that inject 50/60 Hz electrical noise into the signal path, which can lead to false instrumentation trips or corrupted spectral data.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL HAZARD

Before starting the installation or termination of the 9571-02 cable, ensure the corresponding monitor panel loop power is completely de-energized. Verify there is no residual energy on adjacent terminal strips. Failure to isolate power paths can lead to short circuits, damage to delicate input card electronics, or personnel injury.

1 Route the interconnect cable from the transducer mounting point to the monitor cabinet, ensuring the bend radius does not fall below 3 inches (76 mm) to prevent internal wire strain.
2 Align the keying of the 2-socket female connector with the transducer plug. Fully insert and thread the coupling collar to compress the moisture-resistant seal. Hand-tighten securely.
3 Connect the terminal lugs at the opposite end to the assigned screw terminal block of the monitor rack. Ensure the shield drain wire is connected cleanly to the instrument Earth terminal and insulated along the rest of its length.
Loading product navigation…

Can the Bently Nevada 9571-02 cable be used inside a 21128 velocity transducer housing?

No. The 9571-02 is strictly not for use with the 21128 Velocity Transducer Housing due to spatial and mechanical design differences.

What is the physical length and gauge of this interconnect cable?

The 9571-02 cable has a length of 2 feet (approximately 0.6 meters) and features 22 AWG twisted, shielded dual conductors.

How should I ground the shield drain wire for the 9571-02 cable?

The shield drain wire should be grounded at the monitor/instrumentation rack end only. Do not ground it at the transducer end, as this creates ground loops that introduce signal noise.

Is the female connector on the 9571-02 weather-sealed?

Yes, the 2-socket female connector is designed with a moisture-resistant seal to prevent fluid ingress at the transducer junction.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...