Bently Nevada

Bently Nevada 9571-17 Interconnect Cable

SKU 9571-17

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada

  • Product No.: 9571-17

  • Country of origin:United States

  • Product Type: Interconnect Cable

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 280 mm x 280 mm x 25 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Bently Nevada 9571-17 is a heavy-duty, standard interconnect cable assembly optimized for industrial machinery condition monitoring and vibration tracking loops. Engineered with a 2-conductor twisted, shielded pair configuration utilizing high-grade 22 AWG conductors, this rugged assembly serves as the key signal link between transducers—such as the Velomitor piezo-velocity sensors or specialized low-frequency accelerometers—and proximity or vibration monitors. It features an integrated 2-socket moisture-resistant female connector at the sensor-facing terminus and prepared terminal ring lugs at the backend interface for clean cabinet termination. Designed to handle severe industrial conditions, this instrumentation cable provides optimal shielding attenuation to reject electromagnetic interference (EMI) and radio frequency interference (RFI) across extended field runs. The option code 17 specifies a precise fixed length of 17 feet (5.2 meters) to maintain consistent impedance control within customized system layouts without extra coil accumulation.

Features

  • Twisted-Pair Shielded Construction: 22 AWG double-conductor design minimizes inductive crosstalk and cross-talk noise across long industrial signal runs.
  • Moisture-Resistant Connection: Outfitted with an overmolded 2-socket female connector on the field terminus to prevent liquid ingress in humid environments.
  • Pre-Terminated Monitor Lugs: Features durable terminal ring lugs at the cabinet side for direct connection onto terminal strips without field crimping.
  • Wide Thermal Envelope: Rated to withstand continuous operational temperature exposures ranging from -29 degC to +121 degC.
  • Optimized System Length: Pre-cut 17-foot option prevents excess loop storage while satisfying point-to-point field bridging.

Applications

  • Interconnecting Velomitor piezo-velocity sensors with remote diagnostic monitors or continuous monitoring racks.
  • Machinery monitoring systems in oil and gas extraction facilities, petrochemical refining complexes, and municipal pumping stations.
  • Critical absolute casing vibration loops on high-speed rotating equipment, large cooling fans, and industrial pumps.
  • Field routing within protective conduit tracks where severe EMI interference requires high-integrity drain shields.

Ordering Information

Model Code Configuration Option Technical Value Description
9571 Base Assembly Model Standard Interconnect Cable (2-Conductor, 22 AWG, Shielded)
-17 Cable Length Designation 17 feet (5.2 meters) continuous length

Technical Specifications

Parameter Specification Value
Conductor Gauge 22 AWG (0.382 mm2)
Core Arrangement 2-conductor twisted pair with integrated drain wire
Field Connection End 2-socket moisture-resistant female molded connector
Monitor Connection End Pre-installed ring terminal lugs
Operating Temperature Range -29 degC to +121 degC (-20 degF to +250 degF)
Maximum Allowed System Loop 305 meters (1000 feet) maximum total run when matched with approved sensor
Application Constraints Not for use inside the 21128 Velocity Transducer Housing
Manufacturer Bently Nevada (A Baker Hughes Company)
Country of Origin U.S.A.
Shipping Weight (Calculated) 2.0 Kg
Package Dimensions (Calculated) 280 mm x 280 mm x 25 mm

Installation Guidelines

CRITICAL WARNING

Isolate and fully de-energize the machine monitoring system loop prior to pulling, routing, or terminating instrumentation wiring. Handling live field signals near high-energy machinery sections can induce dangerous system loop faults, trigger accidental process shutdowns, or create electrical discharge hazards.

Field engineers must strictly observe the following professional connection sequence:

1
Route the cable through dedicated, grounded steel conduit lines to isolate the 22 AWG twisted pairs from high-voltage motor power feeds.
2
Inspect the 2-socket moisture-resistant female head for any contaminants, debris, or moisture prior to mating with the sensor housing connector receptacle.
3
Engage the female thread assembly tightly onto the sensor receptacle to create a fully sealed environmental barrier against liquid ingress.
4
Land the backend ring terminal lugs securely on the terminal blocks inside the panel enclosure, anchoring the shield wire to the designated instrumentation ground point.

FAQ

What is the physical size and wire structure used inside this cable?

The core assembly consists of a 2-conductor twisted, shielded pair using 22 AWG (0.382 mm2) copper conductors. It includes an integrated drain wire to enable continuous grounding paths across the instrument loop.

Can this interconnect cable be deployed with any velocity sensor?

This cable is designed for standard transducers such as the Velomitor piezo-velocity sensors. However, it is explicitly not compatible for internal routing inside the 21128 Velocity Transducer Housing.

What is the continuous operational temperature limitation for this assembly?

The continuous thermal operating range is rated from -29 degC up to +121 degC (-20 degF to +250 degF), making it suitable for standard machine casing environments.

How is the shielding drain wire handled during multi-point termination?

To prevent dangerous ground loops from interfering with the vibration signal, the shield drain wire should be landed cleanly at one end only, typically at the instrumentation monitor or cabinet common ground strip.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 9571-17 Interconnect Cable

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States

Technical knowledge

Engineering Logix Produced and Consumed Tags

A field-ready guide to Logix produced and consumed tags, covering data contracts, RPI selection, connection status, stale-data handling, commissioning and controller-to-controller troubleshooting.

Commissioning AS-Interface Networks Without Guesswork

A practical AS-Interface commissioning method covering topology, power and voltage-drop checks, addressing, PLC mapping, fault tests and maintenance records for reliable actuator-sensor networks.

Selecting Line Reactors and Output Filters for VFDs

Learn how line reactors, harmonic filters, output reactors, dV/dt filters, and sine filters address different VFD power-quality and motor-cable problems—and how to select them safely.

Light-On and Dark-On Photoelectric Sensor Logic

Learn how light-on and dark-on photoelectric sensor modes interact with through-beam, retroreflective, and diffuse sensing, PNP/NPN wiring, PLC logic, commissioning, and fault detection.

Designing H-Bridge Motor Drives Without Shoot-Through

A practical guide to H-bridge motor drives covering switching states, dead time, inductive current paths, PWM choices, protection, PCB layout, PLC interfacing, and staged commissioning tests.

Designing Mitsubishi FX PLC Sequences with STL and RET

Learn how Mitsubishi FX PLC STL and RET instructions structure conveyor and pneumatic sequences, with practical state design, transition logic, timeouts, diagnostics, and safe restart boundaries.