Bently Nevada

Bently Nevada 9571-33 Standard Interconnect Cable

SKU 9571-33

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada
  • Product No.: 9571-33
  • Origin United States
  • Product Type: Standard Interconnect Cables
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 0.7 kg
  • Dimensions: 33 ft (10 m)
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 9571-33 Standard Interconnect Cable

Quantity

Product Description

Description

The Bently Nevada 9571-33 is a heavy-duty shielded interconnect cable assembly designed to route operational data measurements between machinery transducers and central monitoring systems. This specialized link asset features a 33-foot (10-meter) pre-cut measurement layout built with 0.382 mm2 (22 AWG) internal wire conductors. To preserve field loop integrity within wet or aggressive unconditioned operational locations, the assembly is outfitted with a factory-molded, moisture-resistant female connector at the transducer termination interface, paired with secure ring lugs on the monitor termination side. It provides stable electrical shielding constraints to mitigate high-frequency ground path loop disruptions, helping maintain uncompromised monitoring infrastructure tracking performance over an extended industrial thermal span.

Features

  • Fabricated using robust internal 0.382 mm2 (22 AWG) shielded cabling paths.
  • Factory-terminated with a moisture-resistant female plug on the field transducer end.
  • Pre-outfitted with industrial ring lugs on the control chassis terminal end.
  • Engineered to preserve signaling pathways from harsh external electrical field emissions.

Applications

  • High-integrity dynamic signal routing from field-installed machinery transducers to central machinery protection monitors.
  • Harsh unconditioned process areas requiring specialized moisture-protected connectivity harnesses.
  • Industrial rotating machinery assets demanding continuous, low-noise sensor signal loop integration.

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Model Code 9571-33
Product Type Standard Interconnect Cable
Cable Length 33 ft (10 m)
Conductor Cross-Section 0.382 mm2 (22 AWG)
Cable Design Type Shielded
Transducer Connection Interface Moisture-resistant female connector
Monitor Connection Interface Ring lugs
Operating Temperature Range -29 to 121 degC (-20 to 250 degF)

Connections/Interfaces

Connector Position Connection Interface Type
Transducer End Moisture-resistant female connector
Monitor End Ring lugs

Installation Guidelines

  • Lay out the 33-foot cable run along designated industrial cable trays, keeping the entire path clear of extreme physical compression zones or high-friction edges.
  • Align and couple the moisture-resistant female terminal interface completely onto the transducer thread pin array until the environmental seat is achieved.
  • Secure the ring lug terminations firmly to the monitoring chassis block terminals, ensuring adequate screw tension to prevent vibrational loop interruptions.
  • Separate the sensor communication trajectory from high-voltage primary motor power lines to prevent field noise coupling or transient signal interference.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What are the specific termination interface types provided on either end of the cable?
The transducer terminal end is equipped with a specialized moisture-resistant female connector, while the monitor system end is terminated with industrial ring lugs.
What is the exact physical length and wire size of this specific part assembly?
This model has a pre-cut length of 33 feet (10 meters) and is manufactured using 0.382 mm2 (22 AWG) internal wire conductors.
What are the continuous operating thermal boundaries specified for the device housing?
The cable assembly is rated to operate reliably within an environmental temperature range of -29 to 121 degC (-20 to 250 degF).
Is the cable assembly constructed with electrical noise protection?
Yes, the device is manufactured as a shielded cable assembly to protect sensitive instrumentation loop signals from nearby electromagnetic interference.
Reviews

9571-33

Stock & lead time on request

Call
1 of 3

Bently Nevada 9571-33 Standard Interconnect Cable

Only 4 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 9571-33

  • Country of origin:United States

  • Product Type: Standard Interconnect Cables

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 700g

  • Dimensions: 33 ft (10 m)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Bently Nevada 9571-33 is a heavy-duty shielded interconnect cable assembly designed to route operational data measurements between machinery transducers and central monitoring systems. This specialized link asset features a 33-foot (10-meter) pre-cut measurement layout built with 0.382 mm2 (22 AWG) internal wire conductors. To preserve field loop integrity within wet or aggressive unconditioned operational locations, the assembly is outfitted with a factory-molded, moisture-resistant female connector at the transducer termination interface, paired with secure ring lugs on the monitor termination side. It provides stable electrical shielding constraints to mitigate high-frequency ground path loop disruptions, helping maintain uncompromised monitoring infrastructure tracking performance over an extended industrial thermal span.

Features

  • Fabricated using robust internal 0.382 mm2 (22 AWG) shielded cabling paths.
  • Factory-terminated with a moisture-resistant female plug on the field transducer end.
  • Pre-outfitted with industrial ring lugs on the control chassis terminal end.
  • Engineered to preserve signaling pathways from harsh external electrical field emissions.

Applications

  • High-integrity dynamic signal routing from field-installed machinery transducers to central machinery protection monitors.
  • Harsh unconditioned process areas requiring specialized moisture-protected connectivity harnesses.
  • Industrial rotating machinery assets demanding continuous, low-noise sensor signal loop integration.

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Model Code 9571-33
Product Type Standard Interconnect Cable
Cable Length 33 ft (10 m)
Conductor Cross-Section 0.382 mm2 (22 AWG)
Cable Design Type Shielded
Transducer Connection Interface Moisture-resistant female connector
Monitor Connection Interface Ring lugs
Operating Temperature Range -29 to 121 degC (-20 to 250 degF)

Connections/Interfaces

Connector Position Connection Interface Type
Transducer End Moisture-resistant female connector
Monitor End Ring lugs

Installation Guidelines

  • Lay out the 33-foot cable run along designated industrial cable trays, keeping the entire path clear of extreme physical compression zones or high-friction edges.
  • Align and couple the moisture-resistant female terminal interface completely onto the transducer thread pin array until the environmental seat is achieved.
  • Secure the ring lug terminations firmly to the monitoring chassis block terminals, ensuring adequate screw tension to prevent vibrational loop interruptions.
  • Separate the sensor communication trajectory from high-voltage primary motor power lines to prevent field noise coupling or transient signal interference.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 9571-33 Standard Interconnect Cable

What are the specific termination interface types provided on either end of the cable?

The transducer terminal end is equipped with a specialized moisture-resistant female connector, while the monitor system end is terminated with industrial ring lugs.

What is the exact physical length and wire size of this specific part assembly?

This model has a pre-cut length of 33 feet (10 meters) and is manufactured using 0.382 mm2 (22 AWG) internal wire conductors.

What are the continuous operating thermal boundaries specified for the device housing?

The cable assembly is rated to operate reliably within an environmental temperature range of -29 to 121 degC (-20 to 250 degF).

Is the cable assembly constructed with electrical noise protection?

Yes, the device is manufactured as a shielded cable assembly to protect sensitive instrumentation loop signals from nearby electromagnetic interference.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...