Bently Nevada

Bently Nevada 990-10-XX-01-05 MOD:165353-07 Vibration Transmitter

SKU 990-10-XX-01-05 MOD:165353-07

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada

  • Product No.: 990-10-XX-01-05 MOD:165353-07

  • Country of origin:United States

  • Product Type: 990 Vibration Transmitter

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 15.2 cm x 12.7 cm x 7.6 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

The Bently Nevada 990-10-XX-01-05 MOD:165353-07 is a rugged, two-wire loop-powered vibration transmitter engineered to provide continuous machinery protection for industrial rotating assets. This high-reliability device integrates with proximity probe systems to measure non-contact casing or shaft vibration, transforming physical displacement into a industry-standard 4-20mA analog current signal. Designed specifically for critical assets like centrifugal air compressors, small pumps, motors, and fans, it interfaces directly with Programmable Logic Controllers (PLCs), Distributed Control Systems (DCS), or Supervisory Control and Data Acquisition (SCADA) networks without requiring a separate monitor system.

Key Features

  • Integrated Proximitor Design: Consolidates sensor conditioning and current loop transmitter circuitry into a single, compact DIN-rail mount package.
  • Continuous 4-20mA Output: Delivers a proportional analog current loop for direct SCADA, DCS, or PLC trending, alarm generation, and shutdown logic.
  • Non-Contacting Displacement Tracking: Uses eddy current principles to monitor small fluid-film bearing clearances with extreme accuracy.
  • Hazardous Area Certified: Features multi-agency approvals (indicated by option -05) for deployment in volatile industrial environments.
  • Dynamic Signal Access: Features dedicated BNC terminal points or parallel wiring options for field analysis using portable vibration analyzers.
  • MOD:165353-07 Customization: Factory-modified engineered configuration tailored for specific OEM frequency filters, specific scale factor tuning, or proprietary hardware dampening characteristics.

Heavy Industrial Applications

  • Centrifugal and axial air compressors in petrochemical processing plants.
  • High-speed electric motors and industrial cooling tower fans.
  • Multistage boiler feed water pumps and process fluid pumps.
  • Industrial gas turbines and small steam turbine generator packages.

Technical Specifications

Parameter Specification Value
Manufacturer Bently Nevada (Baker Hughes)
Product Series 990 Series Vibration Transmitter
Full Scale Range Code (-10) Typically configured for 0-10 mils peak-to-peak or 0-250 micrometers peak-to-peak displacement
System Length Option (-XX) Determined by matched probe/cable length configuration (typically 5.0 meter or 9.0 meter system tuned)
Mounting Option (-01) Standard 35mm DIN-rail mount
Agency Approval Code (-05) Multiple hazardous area certifications (ATEX / IECEx / CSA / Class I Div 2)
Modification Code MOD:165353-07 (Specialized filter response / hardware adjustment)
Signal Output Type Linear 4-20mA DC current loop
Power Supply Requirement Loop powered, typical nominal 24V DC input rating
Country of Origin United States
Shipping Weight (Calculated) 0.45 kg
Package Dimensions (Calculated) 15.2 cm x 12.7 cm x 7.6 cm

Field Terminal Connections

Terminal Label Signal / Loop Function
PROBE Coaxial connection input to Bently Nevada Eddy Current Proximity Probe / Extension Cable
COM System common reference / loop ground terminal
SIG / +4-20mA Positive current loop leg connection back to analog input module cards
BUF / OUT Buffered raw voltage dynamic signal output for connection to data loggers and FFT analyzers

Installation & Commisioning Guidelines

CRITICAL FIELD WARNING:

Isolate and lock out all power sources feeding the loop instrument enclosure prior to opening or making termination changes. Failure to completely de-energize circuits in designated hazardous atmospheres can compromise intrinsic safety barriers and risk explosive ignition.

1
DIN Rail Placement: Snaps securely onto standard symmetrical 35mm top-hat DIN rails inside clean, dust-free industrial enclosures. Ensure the orientation allows passive ventilation gaps between adjacent transmitters.
2
Coaxial Probe Integration: Connect the clean, dry extension cable connector from the probe into the primary transmitter receiver hub. Insulate the coaxial connection sleeve completely using silicone self-fusing tape to prevent moisture intrusion or electrical grounding shorts.
3
CTwisted Pair Loop Setup: Wire the 4-20mA current loop terminals using shielded, twisted-pair cable. Connect the cable shield exclusively at the instrumentation rack ground end to prevent field ground loops from injecting noise into the vibration readings.
4
Gap Voltage Calibration: Verify the initial mechanical gap using a digital multimeter at the BUF/COM terminals. Ensure the DC gap voltage settles within the linear range before running machinery to secure proper dynamic response bounds.

FAQ

What does the MOD:165353-07 signify on this vibration transmitter?

The MOD suffix indicates a factory modification. For this device, it designates a specialized engineering modification affecting the internal frequency filtering spectrum, sensor sensitivity calibration, or specific OEM response attributes tailored for distinct machinery platforms.

Does this 990 transmitter require an external Proximitor sensor unit?

No. The 990 series integrates the functions of both a proximity sensor driver and a 4-20mA loop transmitter into one unified block. It hooks up directly to the extension cable and the proximity probe.

How do you capture raw spectrum analysis data from this loop transmitter?

Field technicians can access raw unfound sensor signals through the buffered output terminals. Connecting a portable analyzer or oscilloscope to the BUF and COM lines permits raw diagnostic wave data collection without disrupting the 4-20mA control loop.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States

Technical knowledge

Designing H-Bridge Motor Drives Without Shoot-Through

A practical guide to H-bridge motor drives covering switching states, dead time, inductive current paths, PWM choices, protection, PCB layout, PLC interfacing, and staged commissioning tests.

Designing Mitsubishi FX PLC Sequences with STL and RET

Learn how Mitsubishi FX PLC STL and RET instructions structure conveyor and pneumatic sequences, with practical state design, transition logic, timeouts, diagnostics, and safe restart boundaries.

Selecting and Troubleshooting DIN Valve Connectors

A practical guide to selecting, wiring and diagnosing DIN-style valve connectors, including form identification, coil voltage, suppression, polarity, sealing, release-time effects and commissioning...

PLC or Microcontroller for Arc-Welding Motion Control?

A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...

Piezo Pneumatic Valves: Precision, Power, and Design Limits

Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...

Sensor Timer Functions: When Local Delay Helps PLC Logic

Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...