1 of 3

Bently Nevada 991-06-70-01-CN 991 Thrust Transmitter

Bently Nevada 991-06-70-01-CN 991 Thrust Transmitter

Only 5 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 991-06-70-01-CN

  • Country of origin:United States

  • Product Type: 991 Thrust Transmitter

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 820g

  • Dimensions: 100.1 mm x 73.9 mm x 53.3 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Bently Nevada 991-06-70-01-CN is a 2-wire, loop-powered 991 Thrust Transmitter engineered to measure axial shaft position and thrust displacement on rotating machinery. The transmitter processes raw signals from a compatible proximity probe system and conditions them into a stable 4 to 20 mA DC output directly proportional to mechanical movement. This design allows for direct integration into PLCs, DCS architectures, or SCADA systems without requiring a dedicated machinery protection monitor rack. It provides continuous, cost-effective monitoring for critical industrial assets where axial displacement tracking is required to prevent catastrophic thrust bearing failure.

Features

  • Loop-powered 2-wire architecture reduces field wiring overhead and installation costs.
  • Standard 4 to 20 mA DC analog output connects directly to process control systems.
  • Front-panel BNC jack provides a buffered raw voltage signal for diagnostics and portable data collectors.
  • Non-contacting eddy current sensing technology ensures long-term wear-free operation.
  • Compact, space-saving design suitable for direct high-density DIN rail mounting.

Applications

  • Centrifugal compressor axial thrust displacement monitoring
  • Steam and gas turbine rotor position tracking
  • High-pressure boiler feed pump shaft alignment
  • Industrial gearbox thrust bearing wear diagnostics
  • Forced draft and induced draft fan shaft positioning

Ordering Information

  • 991: Thrust Transmitter
  • 06: 3300 XL 8 mm proximity probe compatibility with 1.0 mm linear range
  • 70: 7.0 metres system length option
  • 01: 35 mm DIN rail mounting option
  • CN: Approvals option certified for specialized regional or country-specific standards (China/NEPSI/GB)

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Country of Origin United States
Product Type Thrust Transmitter
Output Signal 4 to 20 mA DC
Power Input 17 to 30 VDC
Linear Range 1.0 mm (approx. 40 mils)
Transmitter Operating Temperature -35 to +85 Celsius (-31 to +185 deg F)
Transmitter Storage Temperature -51 to +100 Celsius (-60 to +212 deg F)
Probe Operating Temperature -52 to +177 Celsius (-62 to +351 deg F)
Enclosure Material Zinc-plated steel or structural polymer
Mounting Base 35 mm DIN rail mount (or bulkhead mount configuration)
Transmitter Weight 0.43 kg (0.9 lbm)
Total System Weight 0.82 kg (1.8 lbm) typical
Footprint / Base Dimensions 100.1 mm x 73.9 mm (3.94 in x 2.91 in)
Mounting Hole Pattern (Bulkhead) 69.9 mm x 63.5 mm (2.75 in x 2.50 in)
Height (Including DIN Clip) 53.3 mm (2.10 in)
Height (Body Only) 42.6 mm (1.68 in)
Mounting Hole Diameter 5.8 mm (0.23 in), 4 places

Connections / Interfaces

Connector Pin Function
+4-20mA / +VTX Positive Power Supply / Current Loop Input
-4-20mA / -VTX Negative Power Supply / Current Loop Return
PROX Proximity Probe Center Conductor Input
COM Common Reference / Coaxial Shield Terminal
SHLD Instrument Shield Ground Terminal
BNC Jack Dynamic Voltage Signal Output (10.2 mV/micrometer)

Installation Guidelines

  • DIN Rail Attachment: Secure the housing firmly onto a standard 35 mm DIN rail using the integrated DIN mount clips inside a protective industrial enclosure rated IP54 or higher.
  • Bulkhead Mounting Option: Alternatively, use the 4 mounting holes ($5.8 \text{ mm}$ diameter) spaced at $69.9 \text{ mm} \times 63.5 \text{ mm}$ for flat panel/bulkhead installations with the provided 6-32 x 1.326 screws.
  • Shielding Protocol: Connect the input transducer cable shield to the SHLD terminal. The external control loop shield must be grounded at the control system (PLC/DCS) side only to eliminate ground loops.
  • Probe Gapping: Set the physical probe gap using a digital voltmeter across the BNC jack or COM terminals to verify the sensor sits within its linear voltage range before operation.
  • Separation of Wiring: Route all input sensor cables and output current loop wiring away from high-voltage AC lines or variable frequency drive cables to mitigate EMI/RFI noise.

Compliance and Certifications

  • CN Approval Variant (Certified for regional hazardous area compliance, such as NEPSI / GB standards)

FAQ

What are the exact enclosure dimensions for cabinet layout planning?

The base footprint measures 100.1 mm in length by 73.9 mm in width, with a maximum profile height of 53.3 mm when the 35 mm DIN rail clip is attached.

What size are the alternative bulkhead installation holes?

The unit features 4 mounting holes with a diameter of 5.8 mm, laid out in a precise 69.9 mm by 63.5 mm rectangular center pattern.

What is the function of the BNC connector on the faceplate?

It provides an unconditioned, buffered raw voltage output for connecting diagnostic instruments and dynamic signal analyzers without disrupting the 4 to 20 mA current loop.

Does this device require a separate power supply line?

No, it operates entirely on loop power, drawing its operating voltage directly from the 4 to 20 mA signal line.

What happens if the system length option is mismatched with the probe?

Connecting a probe/extension cable combination that does not match the specified 7.0-metre calibration will result in severe measurement non-linearity and scale factor errors.

Can this transmitter be mounted in an outdoor environment?

It must be installed within a weatherproof NEMA 4X or IP65/66 rated field junction box to protect it from moisture, dust, and direct sunlight.

Is the transmitter output compatible with standard analog input cards?

Yes, the 4 to 20 mA output directly connects to standard differential or single-ended analog input cards on any PLC or DCS.

What is the meaning of the CN suffix code?

The CN suffix denotes specific regional certification compliance, commonly matching China national safety and hazardous area standards.

Can the unit be calibrated in the field for different linear ranges?

No, the linear range and scale factors are hard-wired and factory-calibrated. Range changes require a different model configuration.

How does reverse loop polarity affect the transmitter?

The device features internal diode protection against reverse polarity, meaning it will not function when wired backward but will not be damaged.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.
Download Now

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States

Recently Viewed Products

Technical knowledge

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...

Single-Axis Motion Control Setup with CMZ Servo Drives

This tutorial explores the commissioning of a single-axis servo motion system using a CMZ SBD drive, covering hardware setup, axis scaling, homing configuration, and safe motion verification for...

Mitsubishi FX PLC Integration With FR-D700 VFD and HMI Control

This tutorial explains how Mitsubishi FX PLCs integrate with FR-D700 VFDs and HMI panels for forward/reverse motor control. It covers wiring logic, parameter configuration, ladder programming, and...