Bently Nevada

Bently Nevada SCOUT100-Ex Asset Condition Vibration Data Monitor

SKU SCOUT100-Ex

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada

  • Product No.: SCOUT100-Ex

  • Country of origin:United States

  • Product Type: Vibration Analyzers

  • Payment: T/T, Western Union

  • Weight: 1200g

  • Dimensions: 130 mm x 220 mm x 60 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Bently Nevada SCOUT100-Ex is a portable dual-channel vibration data collector, analyzer, and balancer engineered for plant-wide machinery health monitoring and diagnostic routine routes. The device features 2-channel simultaneous analog recording capability, integrated Keyphasor tachometer input, and dynamic balancing functionality. Powered by a high-resolution 5.5-inch HVGA backlit display, it provides spectral resolution up to 6,400 lines and a frequency analysis range up to 40 kHz.

The SCOUT100-Ex integrates with condition monitoring software systems including System 1 Evolution and Ascent Level 2 for database management, route execution, bearing fault identification, and diagnostic reporting. Housed in an IP65 rated enclosure, it supports onboard data storage via 1 GB internal memory, USB memory transfers, and dual-plane balancing routines.

Features

  • 2-channel simultaneous dynamic signal recording
  • Keyphasor tachometer input support
  • 2-plane dynamic field balancing capability
  • 5.5-inch HVGA backlit LCD display
  • Spectral analysis resolution up to 6,400 lines FFT
  • Measurement frequency range up to 40 kHz Fmax
  • 1 GB internal memory for waveform and spectra storage
  • 10-hour battery operating life
  • Ergonomic layout designed for left- and right-handed operation
  • USB host port for data offload to external USB memory drives
  • Supported recording types including Orbit Plot, Order Tracking, Time Synchronous Averaging, and Long Time Waveform

Applications

  • Route-based vibration collection on industrial motors, pumps, fans, and compressors
  • Dual-plane dynamic field balancing on rotating plant machinery
  • Machinery fault diagnosis using orbit plots and order tracking analysis
  • Hazardous area machinery condition monitoring

Technical Specifications

Parameter Specification
Analog Input Channels 2 simultaneous
Maximum Frequency Range (Fmax) 40 kHz
FFT Spectral Lines Up to 6,400 lines
Dynamic Range Greater than or equal to 95 dB
Internal Memory 1 GB
Display 5.5-inch HVGA backlit LCD
Battery Life 10 hours
Measurement Range 1,000 g, 25,000 mm/s, 2,500 mm
Balancing Capability 2-plane / 2-sensor
Ingress Protection IP65

Installation Guidelines

  • Cable Connections: Connect sensors to the channel inputs on the instrument top panel prior to initiating measurement routes. Ensure locking mechanisms on connectors are secured.
  • Sensor Mounting: Attach accelerometers firmly to bearing housings using magnetic bases or direct mounting studs on clean, flat surfaces.
  • Tachometer Setup: Position the optional Laser Tachometer on a magnetic stand aimed at reflective tape applied to the rotating shaft for Keyphasor phase measurements.
  • Hazardous Area Usage: Verify ATEX Zone 2 area classification compliance prior to deploying the instrument in potentially explosive environments.

Compliance and Certifications

  • Hazardous Area Certification: ATEX Zone 2 certified
  • Environmental Enclosure Rating: IP65

FAQ

How many channels can the device record simultaneously?

The device features 2 simultaneous analog input channels for dynamic signal data collection.

What is the battery runtime for this analyzer?

The unit provides up to 10 hours of operating battery life.

What software platforms are compatible with this device?

It is compatible with System 1 Evolution and Ascent Level 2 software.

What hazardous area rating does the unit carry?

The instrument is ATEX Zone 2 certified for hazardous area operation.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada SCOUT100-Ex Asset Condition Vibration Data Monitor

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 2
Only 1 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.