Product Overview

The CC-TDIL11 (CCTDIL11) is a high-availability 24 VDC Digital Input Termination Assembly (IOTA) designed for the Honeywell Experion Series C platform. As a 12-inch redundant termination base, it supports two CC-PDIL01 Digital Input modules in a redundant configuration. This design ensures continuous field signal availability in oil and gas, power generation, and chemical plants. It enables bumpless transition during module failure and allows live replacement without disrupting field wiring or plant operations.

Technical Configuration

The CC-TDIL11 is engineered for high-density installation and stable field signal management in industrial environments.

  • Redundancy Architecture: Supports two I/O modules on a single termination assembly for hardware-level redundancy without external wiring complexity.
  • High-Density Termination: Provides up to 32 input circuits in a compact 12-inch (304 mm) footprint, optimizing cabinet space usage.
  • Integrated Field Power: Distributes field power through the IOTA, removing the need for external marshalling panels.
  • Thermal Design: Uses a tilted module layout to improve airflow and maintain stable operation in high-density cabinets.

Technical Specifications

Model CC-TDIL11
Brand Honeywell Experion Series C
I/O Type Digital Input (Redundant)
Channels 32
Voltage 24 VDC
IOTA Size 12 inch (304 mm)
Redundancy Supported (Dual IOM capacity)
Compatible IOM CC-PDIL01
Field Wiring Two-level detachable terminals
Wire Gauge Up to 12 AWG / 2.5 mm

Technical FAQs

How does CC-TDIL11 improve system availability?
It supports redundant I/O modules. If one module fails, the standby module takes over immediately without process interruption.

Can this IOTA be used for SOE applications?
It supports standard digital inputs. For high-speed SOE systems, dedicated SOE modules are required.

What is the benefit of detachable terminals?
They allow pre-wiring and fast module replacement without disturbing field cable terminations.


Engineering & Installation Guide

  • Install vertically to support airflow and reduce mechanical stress on terminals.
  • Maintain proper spacing around modules to prevent heat accumulation in dense cabinets.
  • Verify active module status indicators before performing replacement in redundant setups.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
United States
Power source
DC Power

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.