Emerson

Emerson PR6423/002-030 CON021 Eddy Current Sensor System

SKU PR6423/002-030 CON021

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Emerson

  • Product No.: PR6423/002-030 CON021

  • Country of origin:United States

  • Product Type: Eddy Current Sensor

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 220g

  • Dimensions: 72 mm x 56 mm x 41 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Emerson PR6423/002-030 CON021 is an eddy current sensor and signal converter system designed for critical turbomachinery applications such as steam, gas, and hydro turbines, compressors, gearboxes, pumps, and fans to measure radial and axial shaft dynamic displacement, position, eccentricity, and speed. The PR6423/002-030 non-contact sensor operates with a PEEK (Polyether Ether Ketone) tip, stainless steel case, and PTFE cable. The system integrates with the CON021 eddy current signal converter to convert probe displacement signals into standardized voltage outputs.

Features

  • Non-contact eddy current measurement for dynamic displacement, position, eccentricity, and speed.
  • Linear measurement range of 2 mm (80 mils) with 0.5 mm (20 mils) initial air gap.
  • High dynamic response featuring frequency range from 0 to 20000 Hz (-3 dB) and rise time <15 microseconds.
  • Signal converter housed in durable LMgSi 0.5 F22 aluminum alloy enclosure.
  • Self-locking Lemo-Plug transducer connection combined with screw terminal type signal and power connections.

Applications

  • Steam turbines
  • Gas turbines
  • Hydro turbines
  • Compressors
  • Gearboxes
  • Industrial pumps and fans

Ordering Information

Suffix Code Breakdown for PR6423/002-030

Code Segment Value Selection / Parameter Meaning
Model PR6423/00 8mm Eddy Current Sensor, M10x1 Thread, Without Armor
Case Thread (X) 2 45 mm Threaded Case Length
Adapter Plug (X) 0 With Adapter Plug
Cable Length (X) 3 8.0 m Cable Length (1m Sensor Cable + 7m Extension Cable / Total System Length)
Cable End (X) 0 Lemo Connector Cable End

Model Selection Matrix

Model Number Sensor Type / Tip Case Threads Armored Cable Cable Length Options Cable End Options
PR6423/00 8mm M10x1 No 4.0m, 5.0m, 8.0m, 9.0m, 10.0m Lemo / Open
CON021 Standard Converter N/A N/A Standard Range (PR6422/PR6423/PR6424/PR6426) Terminal Screws

Technical Specifications

Parameter Specification
Performance  
Linear Measurement Range 2 mm (80 mils)
Initial Air Gap 0.5 mm (20 mils)
Incremental Scale Factor (ISF) 8 V/mm (203.2 mV/mil) +/- 5% @ 0 to 45 degC
Deviation from Best Fit Straight Line (DSL) +/- 0.025 mm (+/- 1 mil) @ 0 to 45 degC
Frequency Range (-3 dB) 0 to 20000 Hz
Rise Time <15 microseconds
Target Requirements  
Minimum Shaft Diameter 25 mm (0.79 in)
Standard Target Material 42CrMo4 (AISI/SAE 4140) Ferromagnetic Steel
Electrical & Power (CON021 Signal Converter)  
Supply Voltage Range (-4V to -20V Output) -23V to -32V
Supply Voltage Range (-2V to -18V Output) -21V to -32V
Mechanical & Environmental  
PR6423 Sensor Operating Temperature Range -35 to +180 degC (-31 to 356 degF)
Cable & Connector Operating Temperature Range -35 to +150 degC (-31 to 302 degF)
CON021 Converter Operating Temperature Range -30 to 100 degC (-22 to 212 degF)
PR6423 Protection Class IP66 (IEC 60529)
CON021 Protection Class IP20
CON021 Shock and Vibration 5g @ 60 Hz @ 25 degC (77 degF)
CON021 Housing Material LMgSi 0.5 F22
PR6423 Materials Tip: PEEK, Case: Stainless Steel, Cable: PTFE, Connector: Brass nickel-plated
PR6423 Weight (Sensor with 1m Cable) Approx. 100 grams (3.53 oz)
CON021 Weight Approx. 120 grams (4.24 oz)

Connections/Interfaces

Connector Pin / Terminal Function
Lemo-Plug (Transducer) Self-locking interface connecting PR6423 Sensor to CON021 Converter
Screw Terminal (Supply/Output) Power input (-24V) and signal voltage output interface (max 1.5 mm2 wire)

Installation Guidelines

  • Mounting: Secure the CON021 housing using 4 x M5x20 screws. Ensure the PR6423 sensor is mounted securely using case threads with SW 11 mm (M10 threads) or SW 7/16 in (3/8-24UNF threads).
  • Minimum Cable Bending Radius: Maintain a minimum bending radius of 25 mm (0.984 in) for standard 2.8 mm cables, or 35 mm (1.378 in) for 6.0 mm armored cables.
  • Wiring Requirements: Use wire sizes up to a maximum of 1.5 mm2 for screw terminal connections.
  • Air Gap Adjustment: Set initial air gap to 0.5 mm (20 mils) prior to dynamic measurement calibration.

Compliance and Certifications

  • CE Directives: 2014/30/EU (EN 61326-1), 2014/34/EU, 2011/65/EU (DIN EN 50581)
  • ATEX Standards: EN 60079-0:2009, EN 60079-11:2012
  • IEC-Ex Standards: IEC 60079-0:2007-10, IEC 60079-11:2011, IEC 60079-26:2006
  • CSA Standards: CAN/CSA-C22.2 NO. 0-M91, CAN/CSA-C22.2 NO. 157-92, CAN/CSA-C22.2 NO. 213-M1987, CAN/CSA-E60079-15-02 (R2006), CAN/CSA-C22.2 NO. 25-1966, CAN/CSA-C22.2 NO. 61010-1-04
  • UL Standards: ANSI/UL Standard 913-2004, ANSI/UL Standard 1604-1995, UL 60079-15 2002, UL 61010-1
  • Intrinsic Safety (ia): ATEX II 2 G Ex ia IIC T4 Gb (-20 degC <= Ta <= 80 degC); IEC-Ex Ex ia IIC T4 Gb (-20 degC <= Ta <= 80 degC); CSA Class I Division 1, Groups A, B, C, D, T4 (-25 degC <= Ta <= 80 degC)
  • Non-sparking (nA): CSA Class I Division 2, Groups A, B, C, D; Ex nA II T3..T4 / AEx nA II T3..T4 (-25 degC <= Ta <= 80 degC)

FAQ

What is the linear measuring range of the probe system?

The probe delivers a 2 mm linear measurement range with an initial set air gap of 0.5 mm.

What power supply voltage is required for the signal converter?

The signal converter operates on a supply voltage range of -23V to -32V or -21V to -32V depending on output range.

Which cable wire gauge is supported by the output terminals?

The supply and output screw terminals accept standard wiring up to a maximum cross-section of 1.5 mm2.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Emerson PR6423/002-030 CON021 Eddy Current Sensor System

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.

Securing Remote PLC Access Beyond the VPN

A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...

Electromagnetic Induction in Industrial Coils

Understand how industrial coils create magnetic force, induce voltage, generate switching transients, and fail in relays, solenoids, transformers, motors, and proximity sensors. in service.

Designing Power and Communication Redundancy

Design control-system redundancy by mapping shared dependencies, separating power and network paths, defining failover behavior, exposing degraded operation, and proof-testing every tolerated fault.

Troubleshooting Industrial Control Cabinets Systematically

A structured control-cabinet troubleshooting method covering safe work, drawings, power paths, branch protection, DC supplies, return circuits, PLC outputs, fault records and repair verification.