1 of 3

Emerson A6120 CSI 6500 Case Seismic Electro-dynamic Vibration Monitor

Emerson A6120 CSI 6500 Case Seismic Electro-dynamic Vibration Monitor

Only 7 item(s) left in stock
  • Manufacturer: Emerson

  • Product No.: A6120

  • Country of origin:United States

  • Product Type: Vibration Monitor Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 3.0 cm x 12.84 cm x 16.0 cm (1.181 in x 5.055 in x 6.300 in)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Emerson A6120 is a Case Seismic Electro-dynamic Vibration Monitor designed for high reliability machinery protection in critical rotating equipment applications. Built as a 2-channel, 3U size, 1-slot plug-in module for the CSI 6500 Machinery Health Monitor rack system, it reduces cabinet space requirements compared to traditional cards. The A6120 interfaces with electro-dynamic differential sensors (such as model numbers 9266, 9267, or 9268) and provides overall vibration monitoring for bearing cases in velocity. It processes vibration inputs with lower cutoff values of 1 or 5 Hz and adjustable upper cutoffs from 50 to 2000 Hz. The unit integrates into plant infrastructure via ModBus TCP/IP outputs, RS-232 configuration interfaces, and 4/20 mA or 0-10 VDC proportional outputs, alongside buffered raw sensor signal outputs.

Features

  • Two-channel, 3U size, 1-slot plug-in module architecture
  • Hot swappable module compliant with API 670 standards
  • Compatibility with electro-dynamic (electro-mechanical) sensor models 9266, 9267, and 9268
  • Remote selectable limit multiply and trip bypass capabilities via relay inputs
  • Front panel and rear buffered outputs alongside proportional 0/4-20 mA and 0-10 VDC outputs
  • Dual LED indicators per channel for channel OK status, alert, and danger alarms
  • Mini DIN front panel socket for configuration and monitoring via RS-232
  • Dedicated 4-channel connector for CSI 4500 interface plug & play support

Applications

  • Steam, gas, and hydro turbomachinery protection
  • Industrial compressors and pumps
  • Nuclear power rotating equipment monitoring
  • Bearing case overall velocity vibration measurements

Ordering Information

Model Number Product Description
A6120 Case Seismic Electro-dynamic Vibration Monitor

Technical Specifications

Category Parameter Specification
Transducer Inputs Number of Inputs Two, independent channels
  Type of Inputs Electro-dynamic (electro-mechanical), differential
  Compatible Sensors Emerson part numbers 9266, 9267, or 9268
  Isolation Galvanically separated from power supply
  Input Resistance >100 kΩ
  Input Voltage Range -5 to +15 VDC
  Input Frequency Range Lower cutoff: 1 or 5 Hz; Upper cutoff: 50 to 2000 Hz adjustable
Measuring Range & Dynamic Range Configurable via software; Vrms (metric) = 5 to 100 mm/s (±25 to ±500 μm); Vrms (English) = 0.197 to 3.937 in/sec (±0.984 to ±19.685 mils)
  Frequency Range 10 to 1000 Hz (VDI 2056, DIN 4566, ISO 3945)
  Selectable Frequency Range 5 to 50 Hz, 10 to 50 Hz, 50 to 1000 Hz, or 50 to 1600 Hz
  Dynamic Input Voltage Min 311 mV peak to peak; Max 9500 mV peak to peak
  Sensor Power Supply Separate buffered sensor supply, galvanically separated, open/short circuit proof
  Lifting Coil Current 0 to 8 mA configurable in steps of 40 μA
  Lifting Coil Accuracy ±0.5% of full scale range, ±0.5% of configured value
  Max Permissible Load 3.4 kΩ at 2 mA
Front Outputs & Controls LEDs 2x OK LEDs (green), 2x Alert/Danger LEDs (red)
  Buffered Outputs Two outputs, ±10 V, >100 kΩ load, 0.1 Hz to 5 kHz (-3 dB)
  Mini DIN Socket Module interface connection for RS-232 configuration/monitoring
Rear Outputs & Analysis Mode Current Outputs 0/4-20 mA per channel, permissible load <500 Ω, accuracy ±1% full scale, settling time 0-10 s
  Mode Voltage Outputs 0 to 10 VDC per channel proportional to main value, open/short circuit proof
  Rear Buffered Outputs Raw buffered signal, 0 to 12 V peak to peak, frequency range 0.1 Hz to 15 kHz (-3 dB), load >10 kΩ
  Communication / Interfaces ModBus TCP/IP output; CSI 4500 4-channel plug & play connector
Alarm Setpoints & Delays Alert & Danger Delays 0 to 5 s per channel (0 to 36 s with A6740 relay card); range 5 to 100% full scale
  Limit Multiply Remote relay input, factor 1.00 to 4.99
  Trip Bypass Remote relay input
Electrical & Mechanical Power Consumption Max 6 W, 250 mA at 24 VDC
  Physical Format PCB/EURO card according to DIN 41494, 100 x 160 mm (3.937 x 6.300 in)
  Dimensions Width: 30.0 mm (1.181 in) (6 TE); Height: 128.4 mm (5.055 in) (3 HE); Length: 160.0 mm (6.300 in)
  Space Requirements 1 slot (14 modules fit into each 19-inch rack)
  Net / Gross Weight Net: approx. 320 g (0.705 lbs); Gross: approx. 450 g (0.992 lbs)
Environmental Protection Rating Module: IP 00; Front Plate: IP 21 (DIN 40050)
  Climate DIN 40040 class KTF
  Operating Temperature 0 to 65 degC (32 to 149 degF)
  Storage Temperature -30 to 85 degC (-22 to 185 degF)
  Relative Humidity 5 to 95%, non-condensing
  Vibration / Shock Vibration: IEC 68-2 part 6 (0.15 mm, 10-55 Hz / 19.6 m/s2, 55-150 Hz); Shock: IEC 68-2 part 29 (98 m/s2 peak, 16 ms)

Installation Guidelines

  • Install the module into a single slot position within the 19-inch CSI 6500 rack system (up to 14 modules per rack).
  • Ensure proper insertion using the front handle plate to lock the EURO card connector into place.
  • Grounding and shielding connection rules must follow standard API 670 guidelines for machinery protection monitoring systems.
  • Maintain clean operating environments compliant with IP 21 front plate rating and IP 00 internal module rating.
  • Ensure ambient operating temperatures remain strictly within 0 to 65 degC.

Compliance and Certifications

  • API 670 Compliant
  • EMC Resistance: EN50081-1 / EN50082-2
  • Vibration Resistance: IEC 68-2, part 6
  • Shock Resistance: IEC 68-2, part 29
  • Environmental/Protection: DIN 40050 (IP 00 / IP 21), DIN 40040 class KTF
Loading product navigation…

Which sensor models interface directly with the vibration monitoring card?

The device connects specifically with electro-dynamic sensor models 9266, 9267, and 9268.

How many card slots does the module require in the rack?

The module occupies exactly 1 slot in a standard 19-inch 3U rack chassis.

What is the maximum power consumption of the module?

The card draws a maximum of 6 W at 250 mA from a 24 VDC power supply.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Micro Drive Specialist EMS Bets on Custom Engineering to Broaden Market Appeal

UK micro-drive specialist EMS is pairing Faulhaber high-torque gearheads and compact motion controllers with in-house custom engineering—aiming beyond catalog sales into tailored mechatronics.

Bringing Object-Oriented Thinking to PLC Programming

Copy-paste ladder does not scale. Object-oriented PLC techniques—user-defined structures and instructions—cut duplication, propagate fixes once, and keep large multi-device programs readable.

Why Process Safety Management Programs Fail Even When OSHA Boxes Are Checked

OSHA boxes checked is not the same as a living PSM system. Refinery history shows programs fail when procedures, training, contractors, and investigations drift from how the plant actually runs.

What Is SCADA? Supervisory Control Without Replacing the PLC

SCADA sits above PLCs and RTUs: it acquires field data, alarms operators, and issues supervisory commands across plants and remote assets—without replacing local deterministic control.

What Is a VFD? Variable Frequency Drives That Actually Move the Needle

A VFD turns fixed-frequency mains into controlled voltage and frequency so AC motors match real load—cutting pump and fan energy while tightening torque, soft-start, and braking behavior.

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.