Emerson

SolaHD SFL24-24-100RED SFL Series Power Supply

SKU SOLA SFL24-24-100RED

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Emerson
  • Product No.: SOLA SFL24-24-100RED
  • Origin United States
  • Product Type: Power Supply
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 2.7 kg
  • Dimensions: 24.4cm x 17.8cm x 8.3cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

SolaHD SFL24-24-100RED SFL Series Power Supply

Quantity

Product Description

Description

The SolaHD SFL24-24-100RED is a DIN Rail mount regulated switch mode power supply configured for parallel operation with active current sharing. This fully integrated redundant model is engineered for N + 1 redundant power supply configurations, supporting up to 5 power supplies to be paralleled simultaneously. The SFL24-24-100RED delivers a maximum output power of 600 Watts at a nominal output voltage of 24 Vdc, accommodating a selectable input voltage range of 115/230 Vac. Designed to expand industrial DC power solutions, it includes standard decoupling diodes and an integrated alarm output to actively signal unit failure conditions.

Features

  • Fully integrated redundant architecture supporting N + 1 power configurations.
  • Active power sharing capability allows up to 5 units to be connected in parallel.
  • Integrated decoupling diodes protect system loop integrity.
  • Built-in alarm output directly signals single unit failure events.
  • Pluggable screw terminal connectors enable simplified field wiring and rapid servicing.
  • Front panel DC OK diagnostic indicator for continuous operational monitoring.

Applications

  • N + 1 redundant industrial power infrastructure 
  • Industrial DC distribution networks 
  • Automation control panel installations 
  • Parallel power configurations requiring active current sharing 

Ordering Information

Catalog Number Input Voltage Selectable Output Voltage Nominal Output Power Maximum Output Current Maximum
SFL 24-24-100RED 115/230 Vac 24 Vdc 600 Watt 24 A

Technical Specifications

Parameter Specification
Manufacturer SolaHD (Sola) 
Input Voltage 115/230 Vac Selectable 
Output Voltage Nominal 24 Vdc 
Output Power Maximum 600 Watt 
Output Current Maximum 24 A 
Mounting Type DIN Rail Mount 
Output Adjustment Adjustable output voltage 
Termination Pluggable screw terminal connectors 
Status Indicators Front panel DC OK indicators 

Installation Guidelines

  • DIN Rail Installation: Secure the unit firmly onto standard symmetric DIN rail channels, ensuring correct orientation for proper convective airflow.
  • Wiring Termination: Utilize the pluggable screw terminal connectors for primary AC input and secondary DC output wiring links to ensure tight terminations.
  • Redundancy Isolation: Multiple individual units are strictly required to configure a complete functional redundant power system setup.

Compliance and Certifications

  • UL Listed: UL 508 Listed, Ind. Cont. Eq. E61379 
  • UR Recognized: UL 60950, E137632 
  • cUL/CSA Certified: CUL/CSA-C22.2 No. 234-M90 
  • CE: Compliant with EMC and Low Voltage Directives 
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
How many power supplies can be paralleled using this specific model?
This redundant model allows up to 5 power supplies to be paralleled in N + 1 redundant configurations.
What standard safety diagnostic features are integrated into the device?
The device features front panel 'DC OK' indicators, integrated decoupling diodes, and an alarm output to signal a unit failure.
Does the power supply require an external diode block for parallel redundancy?
No, decoupling diodes are fully integrated into this specific version, facilitating direct parallel connection with power sharing.
Reviews

SOLA SFL24-24-100RED

Stock & lead time on request

Call
1 of 3

SolaHD SFL24-24-100RED SFL Series Power Supply

Only 6 item(s) left in stock
  • Manufacturer: Emerson

  • Product No.: SOLA SFL24-24-100RED

  • Country of origin:United States

  • Product Type: Power Supply

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 2700g

  • Dimensions: 24.4cm x 17.8cm x 8.3cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The SolaHD SFL24-24-100RED is a DIN Rail mount regulated switch mode power supply configured for parallel operation with active current sharing. This fully integrated redundant model is engineered for N + 1 redundant power supply configurations, supporting up to 5 power supplies to be paralleled simultaneously. The SFL24-24-100RED delivers a maximum output power of 600 Watts at a nominal output voltage of 24 Vdc, accommodating a selectable input voltage range of 115/230 Vac. Designed to expand industrial DC power solutions, it includes standard decoupling diodes and an integrated alarm output to actively signal unit failure conditions.

Features

  • Fully integrated redundant architecture supporting N + 1 power configurations.
  • Active power sharing capability allows up to 5 units to be connected in parallel.
  • Integrated decoupling diodes protect system loop integrity.
  • Built-in alarm output directly signals single unit failure events.
  • Pluggable screw terminal connectors enable simplified field wiring and rapid servicing.
  • Front panel DC OK diagnostic indicator for continuous operational monitoring.

Applications

  • N + 1 redundant industrial power infrastructure 
  • Industrial DC distribution networks 
  • Automation control panel installations 
  • Parallel power configurations requiring active current sharing 

Ordering Information

Catalog Number Input Voltage Selectable Output Voltage Nominal Output Power Maximum Output Current Maximum
SFL 24-24-100RED 115/230 Vac 24 Vdc 600 Watt 24 A

Technical Specifications

Parameter Specification
Manufacturer SolaHD (Sola) 
Input Voltage 115/230 Vac Selectable 
Output Voltage Nominal 24 Vdc 
Output Power Maximum 600 Watt 
Output Current Maximum 24 A 
Mounting Type DIN Rail Mount 
Output Adjustment Adjustable output voltage 
Termination Pluggable screw terminal connectors 
Status Indicators Front panel DC OK indicators 

Installation Guidelines

  • DIN Rail Installation: Secure the unit firmly onto standard symmetric DIN rail channels, ensuring correct orientation for proper convective airflow.
  • Wiring Termination: Utilize the pluggable screw terminal connectors for primary AC input and secondary DC output wiring links to ensure tight terminations.
  • Redundancy Isolation: Multiple individual units are strictly required to configure a complete functional redundant power system setup.

Compliance and Certifications

  • UL Listed: UL 508 Listed, Ind. Cont. Eq. E61379 
  • UR Recognized: UL 60950, E137632 
  • cUL/CSA Certified: CUL/CSA-C22.2 No. 234-M90 
  • CE: Compliant with EMC and Low Voltage Directives 

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

SolaHD SFL24-24-100RED SFL Series Power Supply

How many power supplies can be paralleled using this specific model?

This redundant model allows up to 5 power supplies to be paralleled in N + 1 redundant configurations.

What standard safety diagnostic features are integrated into the device?

The device features front panel 'DC OK' indicators, integrated decoupling diodes, and an alarm output to signal a unit failure.

Does the power supply require an external diode block for parallel redundancy?

No, decoupling diodes are fully integrated into this specific version, facilitating direct parallel connection with power sharing.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Red
Country of origin
United States

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...