Emerson PR6426/010-000 CON021/916-160 Eddy Current Sensor System
SKU PR6426/010-000 CON021/916-160
In stock
No reviews
12-month warranty
Free returns within 30 days
Manufacturer:
Emerson
Product No.:
PR6426/010-000 CON021/916-160
Country of origin:United States
Product Type:
Eddy Current Displacement Sensors
Barcode:
8537101190
Payment:
T/T, Western Union
Weight:
920g
Dimensions:
23cm x 20cm x 5cm
Shipping port:
Xiamen
Warranty:
12 months
Description
The Emerson PR6426/010-000 non-contact sensor combined with the CON021/916-160 signal converter forms an industrial eddy current measurement system optimized for critical turbomachinery applications, including steam, gas, and hydro turbines, compressors, pumps, and fans. The PR6426 eddy current sensor detects radial and axial shaft displacement, position, eccentricity, and motion under harsh operating conditions. The matched CON021/916-160 converter accurately processes these proximity metrics into reliable electrical signals required by machinery protection and TSI monitoring platforms.
Features
Non-contact eddy current measurement technique for precise tracking of shaft position and dynamics
Robust engineering built to withstand demanding and tough industrial conditions
Sensor tip assembly capable of enduring high pressure up to 6,500 hpa
Stable signal translation over an extended displacement range up to 16.0mm
Unarmored cable layout equipped with a premium self-locking plug connector interface
Applications
Radial and axial shaft dynamic displacement monitoring
Turbomachinery position, motion, and eccentricity registration
Comprehensive mechanical protection loops for high-speed gas/steam turbines and heavy compressors
Ordering Information
Model Number
Configuration / Description
Measuring Range
Linearity Error
PR6426/010-000
32mm Eddy Current Sensor, No Sleeve Thread, Unarmored Cable, Mounting Plate, Without Adaptor Plug
+/-4.0 mm (Standard Range) / 16.0mm Extended
<= 1.5% max (Sensor)
CON021/916-160
Sensor Signal Converter for PR6426
16.0mm (Extended Range)
<= 2.0%
Technical Specifications
CON021/916-160 Signal Converter Specifications
Parameter
Specification
Manufacturer
Emerson
Frequency Range (-3 dB)
0 to 20000 Hz
Rise Time
<15 us
Operating Temperature Range
-30 to 100 degC (-22 to 212 Fahrenheit)
Shock and Vibration
5g @ 60 Hz @ 25 degC (77 Fahrenheit)
Protection Class
IP20
Supply Voltage Range (-24V config)
-23V to -32V (Output Range: -4V to -20V)
Supply Voltage Range (-2V config)
-21V to -32V (Output Range: -2V to -18V)
Housing Material
LMgSi 0.5 F22
Weight
~120 grams (4.24 oz)
Mounting Hardware
4 Screws M5x20
PR6426 Eddy Current Sensor Specifications
Parameter
Specification
Tip Diameter
32mm
Sensitivity
2 V/mm (50.8 mV/mil) <= +/-1.5% max
Air Gap (Center)
Approx. 5.5 mm (0.22") Nominal
Long Term Drift
<0.3%
Target/Surface Material
Ferromagnetic Steel (42 Cr Mo 4 Standard)
Maximum Surface Speed
2,500 m/s (98,425 ips)
Minimum Shaft Diameter
200 mm (7.87")
Operating Temperature Range
-35 to 175 degC (-31 to 347 Fahrenheit)
Temperature Excursions (<4 Hours)
200 degC (392 Fahrenheit)
Maximum Cable Temperature
200 degC (392 Fahrenheit)
Pressure Resistance to Sensor Head
6,500 hpa (94 psi)
Shock and Vibration
5g (49.05 m/s2) @ 60Hz @ 25 degC (77 Fahrenheit)
Sleeve Material
Stainless Steel
Cable Material
PTFE
Weight (Sensor & 1M Cable, no Armor)
~800 grams (28.22 oz)
Connections/Interfaces
Connector Pin / Terminal
Function
Transducer Connection
Self-Locking Lemo-Plug
Supply/Output Connection
Screw Terminal Type (max. 1.5mm2 wire)
Installation Guidelines
Ensure the unarmored sensor cable respects a minimum static bending radius of 25 mm during routing.
Keep a clear exclusion zone of at least 80 mm diameter centered around the 32mm sensor head to eliminate peripheral metal interference.
Adjust the mechanical probe position to find the nominal center air gap of approximately 5.5 mm before locking down.
Use appropriate safety barriers and signal isolation paths when routing transducer loops through explosive or certified hazardous zones.
Compliance and Certifications
CE: 2014/30/EU (EN 61326-1), 2014/34/EU, 2011/65/EU, DIN EN 50581
ATEX: EN 60079-0, EN 60079-11 (II 2 G Ex ia IIC T4 Gb, -20 degC <= Ta <= 80 degC)
IEC-Ex: IEC 60079-0, IEC 60079-11, IEC 60079-26 (Ex ia IIC T4 Gb, -20 degC <= Ta <= 80 degC)
CSA: CAN/CSA-C22.2 NO. 0-M91, NO. 157-92, NO. 213-M1987, CAN/CSA-E60079-15-02, NO. 25-1966, NO. 61010-1-04 (Class I Division 1, Groups A, B, C, D, T4; Class I Division 2, Groups A, B, C, D Ex nA II T3..T4)
Standards: ANSI/UL Standard 913-2004, ANSI/UL Standard 1604-1995, UL 60079-15 2002, UL 61010-1
FAQ
What measurement span does this specific extended sensor configuration provide?
When mated with the extended range converter, this 32mm eddy current sensor configuration delivers a total linear measurement span of 16.0mm.
What type of cable construction is used on this exact sensor model?
This specific model features an unarmored PTFE cable configuration terminating in a self-locking Lemo plug connector.
What are the ambient temperature classifications under the CSA standard for this device?
The sensor temperature classification is graded as T6 for ambient temperatures up to 64 degC, T4 up to 114 degC, and T3 up to 160 degC.
A field replacement guide for GE Fanuc IC200MDL650 covering revision-dependent negative logic, four common groups, 24 VDC thresholds, input filtering, carrier checks and commissioning records.
A field-focused IC697CPX935 replacement guide covering fast memory, firmware-dependent serial behavior, rack power, cooling, I/O architecture and backup records.
A field-focused IC693DSM324 replacement guide covering Series 90-30 host checks, FSSB servo-chain records, 5 V power budget, firmware limits, follower control and commissioning.