BECKHOFF

EPI2008-0002 | BECKHOFF | IO-Link Box Digital I/O Module

SKU EPI2008-0002

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: EPI2008-0002

  • Country of origin:Germany

  • Product Type: IO-Link box

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The EPI2008-0002 is a robust IO-Link box from Beckhoff, designed to provide flexible and decentralized I/O connectivity in industrial environments. This module functions as an IO-Link V1.1 (Class B) device, featuring 8 digital inputs for high-density signal acquisition. It supports a data transfer rate of 230.4 kbaud (COM 3) and is engineered with an IP65/66/67 protection rating, making it suitable for direct field mounting without the need for an additional control cabinet.

Features

  • 8 digital inputs via M12 screw-type connectors
  • IO-Link communication (Specification V1.1, Class B)
  • Supports COM 3 (230.4 kbaud) data transfer rates
  • Individual short-circuit protection per channel (0.5 A max output)
  • High protection rating (IP65/66/67) for harsh environments
  • Electrical isolation between L+ and P24

Technical Specifications

Feature Specification
Manufacturer Beckhoff
Model EPI2008-0002
Communication IO-Link V1.1, Class B
Data Transfer Rate 230.4 kbaud (COM 3)
Interface 1 x M12 plug, A-coded
Number of Inputs 8
Nominal Input Voltage 24 V DC (-15 %/+20 %)
Max. Output Current 0.5 A per channel
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Protection Rating IP65/66/67
Weight Approx. 165 g

Installation Guidelines

  • Mounting: Due to its IP65/66/67 rating, this module can be mounted directly on machinery or in open field locations. Ensure the mounting surface is vibration-resistant according to EN 60068-2-6.
  • Connectivity: Use M12 A-coded cables for IO-Link communication and M12 screw-type connectors for the 8 digital inputs.
  • Power Supply: The module requires 24 V DC. Ensure current consumption (100 mA from L+ and 20 mA + load for auxiliary power) is within the specifications of your power distribution system.
  • Environment: While protected against dust and water (IP67), avoid mounting in areas where chemicals not compatible with the housing material might be present.

Compliance and Certifications

  • CE
  • UL
  • EMC: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Environmental: Conforms to EN 60529 (IP rating)

FAQ

What is the IO-Link specification version of the EPI2008-0002?

The module complies with IO-Link V1.1, Class B specifications.

How many digital inputs are available on this module?

The module features 8 digital inputs using M12 screw-type connectors.

What protection rating does this IO-Link box have?

It is rated IP65/66/67, making it suitable for harsh industrial environments and direct field mounting.

What is the maximum output current per channel?

The module supports a maximum output current of 0.5 A per channel, with individual short-circuit proofing.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Germany

Technical knowledge

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.

Replacing an Allen-Bradley 1785-L40B: PLC-5/40 Checks Before Migration

A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.

Allen-Bradley 1747-SN: RIO Mapping and Link Fault Checks

Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.