The EPI2008-0002 is a robust IO-Link box from Beckhoff, designed to provide flexible and decentralized I/O connectivity in industrial environments. This module functions as an IO-Link V1.1 (Class B) device, featuring 8 digital inputs for high-density signal acquisition. It supports a data transfer rate of 230.4 kbaud (COM 3) and is engineered with an IP65/66/67 protection rating, making it suitable for direct field mounting without the need for an additional control cabinet.

Features

  • 8 digital inputs via M12 screw-type connectors
  • IO-Link communication (Specification V1.1, Class B)
  • Supports COM 3 (230.4 kbaud) data transfer rates
  • Individual short-circuit protection per channel (0.5 A max output)
  • High protection rating (IP65/66/67) for harsh environments
  • Electrical isolation between L+ and P24

Technical Specifications

Feature Specification
Manufacturer Beckhoff
Model EPI2008-0002
Communication IO-Link V1.1, Class B
Data Transfer Rate 230.4 kbaud (COM 3)
Interface 1 x M12 plug, A-coded
Number of Inputs 8
Nominal Input Voltage 24 V DC (-15 %/+20 %)
Max. Output Current 0.5 A per channel
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Protection Rating IP65/66/67
Weight Approx. 165 g

Installation Guidelines

  • Mounting: Due to its IP65/66/67 rating, this module can be mounted directly on machinery or in open field locations. Ensure the mounting surface is vibration-resistant according to EN 60068-2-6.
  • Connectivity: Use M12 A-coded cables for IO-Link communication and M12 screw-type connectors for the 8 digital inputs.
  • Power Supply: The module requires 24 V DC. Ensure current consumption (100 mA from L+ and 20 mA + load for auxiliary power) is within the specifications of your power distribution system.
  • Environment: While protected against dust and water (IP67), avoid mounting in areas where chemicals not compatible with the housing material might be present.

Compliance and Certifications

  • CE
  • UL
  • EMC: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Environmental: Conforms to EN 60529 (IP rating)

What is the IO-Link specification version of the EPI2008-0002?

The module complies with IO-Link V1.1, Class B specifications.

How many digital inputs are available on this module?

The module features 8 digital inputs using M12 screw-type connectors.

What protection rating does this IO-Link box have?

It is rated IP65/66/67, making it suitable for harsh industrial environments and direct field mounting.

What is the maximum output current per channel?

The module supports a maximum output current of 0.5 A per channel, with individual short-circuit proofing.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Germany

Recently Viewed Products

Technical knowledge

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...