General Electric

GE DS3820AIQA1A1A Mark IV Turbine Control Card

SKU DS3820AIQA1A1A

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: General Electric

  • Product No.: DS3820AIQA1A1A

  • Country of origin:United States

  • Product Type: Turbine Control Card

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 3300g

  • Dimensions: 46.8cm x 31.7cm x 6cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The DS3820AIQA1A1A functions as a specialized process regulation and hardware monitoring board developed for the Mark IV Speedtronic turbine control sequence. This auxiliary circuit assembly processes critical machine variables within complex programmable logic controller (PLC) structures, safeguarding parameters to sustain operational limits across core industrial turbine setups.

The fundamental configuration of the DS3820AIQA1A1A leverages extensive component distribution networks to execute low-drift electronic steering. The board layout relies on eleven discrete semi-conductive transistors to modify and amplify electrical control lines, alongside a protective diode matrix featuring 32 large bright red diodes, 16 large bright yellow diodes, and 65 small teal blue diodes tasked with securing unidirectional energy paths. High-density board routing is maintained via 65 light-colored miniature resistors and 16 large black resistors structured to suppress power surges. For structural deployment, the card features four integrated metal platforms mounted between eight large black rectangular blocks; three platforms carry twelve retaining screws while the fourth platform integrates seventeen screws. Real-time board-to-board communication data frames are distributed using four small 10-pin blue male headers and six larger 26-pin blue male interface sockets, pairing the assembly tightly to neighboring controller panels.

Features

  • High-Density Signal Interconnection: Equipped with 4 ten-pin and 6 twenty-six-pin male blue connection terminals to coordinate error-free data transfer with surrounding circuit arrays.
  • Heavy Diode Suppression Matrix: Features 113 specialized color-coded diodes to strictly regulate current directionality and isolate core circuits from electrical feedback loops.
  • Robust Thermal Protection Limits: Built to withstand shifting environmental stresses, guaranteeing continuous performance in highly demanding industrial automated locations.
  • Rigid Structural Screw Anchoring: Integrates four metal platforms carrying heavy screw distributions to securely tie core processing tracks to the chassis baseplate.

Applications

  • Industrial Gas and Steam Turbine Control: Configured as a high-reliability controller card within Speedtronic panels to manage continuous turbine velocity loops.
  • Power Generation Grid Synchronization: Processes load balance diagnostics and tracking signals to ensure safe mechanical operations in large power plants.
  • Large-Scale Automated Manufacturing Control: Functions within core industrial PLC frameworks to stabilize high-capacity processing lines and peripheral machinery loops.

Technical Specifications

Parameter Specification
Manufacturer General Electric
Model DS3820AIQA1A1A
Product Series Mark IV Speedtronic Series
Module Type Turbine Control Card
Transistor Count 11 Small Black Transistors
Total Diode Allocation 32 Large Red, 16 Large Yellow, 65 Small Teal Blue Diodes
Resistor Network Grouping 65 Light-Colored Miniature, 16 Large Black Resistors
Operating Temperature Range 0 degC to +60 degC
Storage Temperature Range -20 degC to +70 degC
Humidity Operating Range 5% to 95% Non-Condensing
Mounting Interface Hardware Two thin metal edges with two screw ports on either side

Connections/Interfaces

Connector Type Quantity Pin Configuration Function
Small Blue Male Terminals 4 10 Metal Pins per Terminal Board-to-board control signal synchronization
Large Blue Male Terminals 6 26 Metal Pins per Terminal Primary data trunk bus and peripheral line mapping

Installation Guidelines

  • Main Panel Isolation: Prior to inspecting, inserting, or servicing the module, confirm that all high-voltage and logic-level power distribution circuits are completely disconnected and tagged out.
  • Electrostatic Control Implementation: Maintenance staff must clip a verified, grounded ESD anti-static wristband into place before opening the protective envelope or touching any on-board resistors or transistors.
  • Rigid Chassis Seating: Guide the assembly using the two thin metal outer edges, lining up the card correctly inside the rack channel before tightening the panel fasteners down into their corresponding screw ports.
  • Interface Cable Engagement: Connect the 10-pin and 26-pin ribbon header assemblies straight onto the blue male interface terminals, ensuring all physical guide pins are locked into place to prevent tracking faults under heavy vibration.

FAQ

What is the certified operating temperature boundary for the DS3820AIQA1A1A board?

The board operates reliably across a temperature range of 0 degC to +60 degC, making it suitable for standard industrial control enclosures.

How many external interface connectors are built onto this turbine control board?

The card features ten total blue male connection terminals, divided into four small 10-pin ports and six larger 26-pin ports.

Does this control board handle moisture-heavy industrial conditions?

Yes. The module features robust relative humidity resilience, rated to perform across a non-condensing envelope from 5% to 95%.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
United States

Technical knowledge

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...

Commissioning a Linear Axis Without Hiding Mechanical Faults

A linear axis should be proven mechanically before aggressive tuning begins. This commissioning workflow covers scaling, direction, limits, homing, STO, low-speed tests, and evidence-based tuning for...