General Electric

GE Horner HE693RTD600T Series 90-30 Resistance Temperature Device Input Module

SKU HE693RTD600T

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: General Electric
  • Product No.: HE693RTD600T
  • Origin United States
  • Product Type: RTD Temperature Module
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 0.45 kg
  • Dimensions: 130 mm x 130 mm x 35 mm (H x W x D)
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The HE693RTD600T is a high-precision resistance temperature device (RTD) input module developed by GE Horner for the Series 90-30 programmable logic controller platform. This module allows direct connection of RTD temperature sensors to the PLC without requiring external transmitters, transducers, or signal conditioning hardware. It performs all analog and digital processing directly on the module, writing formatted temperature readings in 0.5 degC or 0.5 degF increments directly to the controller %AI input table. Equipped with six independent channels, the device ensures reliable and localized temperature tracking across diverse industrial environments.

Features

  • Six individual channels supporting multi-point temperature sensor integration
  • Onboard 16-bit integrating analog-to-digital converter for high-resolution signal processing
  • Built-in fault protection utilizing a Zener diode clamp to safeguard internal circuitry
  • High input impedance to preserve signal integrity over long field wiring runs
  • Direct reporting of temperature values to the controller memory map without external signal conversion

Applications

  • Real-time temperature monitoring in process control industries
  • Machinery thermal protection systems
  • Multi-channel HVAC and environmental control networks
  • Power generation and distributed system thermal logging

Technical Specifications

Parameter Specification
Manufacturer GE Horner
Model HE693RTD600T
Product Line Series 90-30 PLC
Module Type Resistance Temperature Device (RTD) Input Module
Number of Channels 6
I/O Points Required 6 %AI
Power Consumption 75 mA at 5 VDC
Input Impedance Greater than 1000 Megohms
Fault Protection Zener Diode Clamp
A/D Conversion Type 16-bit, Integrating
Update Time 50 Channels per second
Channel-to-Channel Tracking 0.1 degC
Resolution 0.1 degC
Measurement Accuracy +/- 0.5 degC typical

Installation Guidelines

  • Install the module directly into a compatible slot of the Series 90-30 PLC rack, ensuring it is fully seated.
  • Connect field sensors using shielded, twisted-pair extension wiring to provide maximum electrical noise immunity.
  • Ground the wiring shields at a single point only; if grounding at the module end, utilize the designated shield ground terminal points.
  • Route RTD signal cables away from high-voltage lines, motor conduits, and other significant sources of electromagnetic interference.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
How many channels does the device support for sensor connections?
The device provides six independent input channels for direct connection to temperature sensors.
What is the typical internal power consumption of the module?
The module has a typical power consumption of 75 mA from the 5 VDC system power supply.
Does the module require external signal transmitters or transducers?
No, the module processes sensor signals directly and writes the digitized data straight to the controller input table.
Reviews

HE693RTD600T

Stock & lead time on request

Call
1 of 3

GE Horner HE693RTD600T Series 90-30 Resistance Temperature Device Input Module

Only 3 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: HE693RTD600T

  • Country of origin:United States

  • Product Type: RTD Temperature Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 130 mm x 130 mm x 35 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The HE693RTD600T is a high-precision resistance temperature device (RTD) input module developed by GE Horner for the Series 90-30 programmable logic controller platform. This module allows direct connection of RTD temperature sensors to the PLC without requiring external transmitters, transducers, or signal conditioning hardware. It performs all analog and digital processing directly on the module, writing formatted temperature readings in 0.5 degC or 0.5 degF increments directly to the controller %AI input table. Equipped with six independent channels, the device ensures reliable and localized temperature tracking across diverse industrial environments.

Features

  • Six individual channels supporting multi-point temperature sensor integration
  • Onboard 16-bit integrating analog-to-digital converter for high-resolution signal processing
  • Built-in fault protection utilizing a Zener diode clamp to safeguard internal circuitry
  • High input impedance to preserve signal integrity over long field wiring runs
  • Direct reporting of temperature values to the controller memory map without external signal conversion

Applications

  • Real-time temperature monitoring in process control industries
  • Machinery thermal protection systems
  • Multi-channel HVAC and environmental control networks
  • Power generation and distributed system thermal logging

Technical Specifications

Parameter Specification
Manufacturer GE Horner
Model HE693RTD600T
Product Line Series 90-30 PLC
Module Type Resistance Temperature Device (RTD) Input Module
Number of Channels 6
I/O Points Required 6 %AI
Power Consumption 75 mA at 5 VDC
Input Impedance Greater than 1000 Megohms
Fault Protection Zener Diode Clamp
A/D Conversion Type 16-bit, Integrating
Update Time 50 Channels per second
Channel-to-Channel Tracking 0.1 degC
Resolution 0.1 degC
Measurement Accuracy +/- 0.5 degC typical

Installation Guidelines

  • Install the module directly into a compatible slot of the Series 90-30 PLC rack, ensuring it is fully seated.
  • Connect field sensors using shielded, twisted-pair extension wiring to provide maximum electrical noise immunity.
  • Ground the wiring shields at a single point only; if grounding at the module end, utilize the designated shield ground terminal points.
  • Route RTD signal cables away from high-voltage lines, motor conduits, and other significant sources of electromagnetic interference.

How many channels does the device support for sensor connections?

The device provides six independent input channels for direct connection to temperature sensors.

What is the typical internal power consumption of the module?

The module has a typical power consumption of 75 mA from the 5 VDC system power supply.

Does the module require external signal transmitters or transducers?

No, the module processes sensor signals directly and writes the digitized data straight to the controller input table.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...