General Electric

GE Multilin UR-6UH UR Series Digital I/O Module

SKU UR-6UH

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: General Electric

  • Product No.: UR-6UH

  • Country of origin:Canada

  • Product Type: Digital I/O Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1150g

  • Dimensions: 18 cm x 15 cm x 4 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The GE Multilin UR-6UH is a high-performance modular plug-and-play component designed for the Universal Relays (UR) series to facilitate discrete status monitoring and auxiliary asset management. This specific digital input/output variant provides the core relay chassis with six Form-A outputs (without monitoring capabilities) and four high-speed digital contact inputs. Operating as a reliable intersystem communications link within a substation network, the GE Multilin UR-6UH enables real-time supervision and automated physical control over external switchgear and field breakers. By using direct discrete binary encoding instead of traditional unshielded analog circuits, this card significantly limits baseline electrical noise propagation and minimizes hardware deployment costs across automated power grid environments.

Features

  • Optimized Discrete Density: Configured with 4 independent digital contact inputs engineered for real-time telemetry verification of secondary substation state transitions.
  • Form-A Relay Contacts: Equipped with 6 Form-A standard outputs tailored for robust open/close control signaling over auxiliary switchgear components.
  • Modular Plug-and-Play Footprint: Engineered for rapid slot exchange inside the UR series frame, facilitating fast uptime and reduced field servicing times.
  • Enhanced Noise Suppression: Native digital architecture produces less electrical noise cross-talk compared to conventional unshielded analog processing interfaces.
  • Dual-Interface Calibration: Supports unified software configuration via the EnerVista UR platform as well as direct physical adjustment through the front panel keypad and integrated LCD.

Applications

  • Distributed monitoring of substation auxiliary switches and breaker status loops.
  • Interlocking and safety command routing across primary utility control networks.
  • Real-time contact monitoring and local alarm initiation inside industrial automated switchgear.
  • Remote equipment management and status tracking in transmission distribution centers.

Ordering Information

Suffix Code Description
6U 6 Form-A (No Monitoring) Outputs, 4 Digital Inputs
H Standard/High-Voltage Hardware Interface Suffix

Technical Specifications

Parameter Specification
Manufacturer GE Multilin
Manufacturing Location Ontario, Canada
Module Series Type Universal Relays (UR) Series Platform
Configuration Code 6U (6 Form-A Outputs / 4 Digital Inputs)
Output Feature Profile No Monitoring
System Interface Configuration EnerVista UR Software / Front Panel Keypad & LCD
Weight 1.15 kg
Dimensions (L x W x H) approx. 18 cm x 15 cm x 4 cm

Installation Guidelines

Slot Replacement and Insertion

Completely isolate the main Universal Relay housing from any active auxiliary control power lines before handling. Align the outer structural boundaries of the module card along the designated rear card guides (typically slots H, M, P, U, or W) and apply continuous force until the pin block seats firmly onto the backplane. Secure the structural thumb latch retaining screws.

Interface Mapping and Setup

Once the module is locked in place, activate the relay mainframe and launch the EnerVista UR utility program on a connected workstation to register the new hardware configuration. Alternatively, adjust contact processing logic variables manually using the front-panel matrix button array and localized text display screen.

Signal Separation

Ensure all digital connection runs leading to the discrete input pins are physically routed away from primary alternating current (AC) power lines and raw unshielded current transformer (CT) lines to maintain absolute signal integrity against inductive voltage surges.

FAQ

Does the UR-6UH module feature internal current or voltage monitoring for its relay outputs?

No, this specific module variation provides standard six Form-A outputs without any built-in current or voltage monitoring circuitry.

Which available slots on a T60 relay chassis can host this digital I/O card?

According to the universal order code structure, digital I/O modules can be integrated into positions designated by slots H, M, P, U, or W.

What interface options are available to modify the parameters of this module after a field replacement?

System parameters can be adjusted electronically using the EnerVista UR software suite or directly via the physical front-panel buttons and built-in LCD interface.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Canada

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...