1 of 3

HIMA F 3236 HIQuad X 16-Channel Digital Input Module

HIMA F 3236 HIQuad X 16-Channel Digital Input Module

Only 10 item(s) left in stock
  • Manufacturer: HIMA

  • Product No.: F3236

  • Country of origin:Germany

  • Product Type: Digital Input Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 2cm x 19cm x 12.7cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The F 3236 (also designated as F3236) is a safety-related 16-channel digital input module engineered for integration within the HIQuad X programmable electronic system. This hardware device acts as a safe separation component for processing binary data from field instrumentation sensors or mechanical contacts into the central system logic. The module automatically executes self-testing subroutines during operation, performing cross-talking checks with a walking-zero test sequence and inspecting internal filter capacitor health to maintain predictable safety parameters. To ensure direct signal routing to marshalling cabinets or field accessories, the assembly utilizes custom-matched HIQuad X system cables with dedicated front cable plug connections.

Features

  • Provides 16 safety-related digital input processing channels
  • Automated full operational self-testing covering walking-zero input cross-talking parameters
  • Continuous hardware diagnostic monitoring of onboard filter capacitor functionality
  • Safe separation architecture certified for safety-critical plant application deployment

Applications

  • Safety-related automation input signal monitoring
  • High-integrity plant discrete loop processing
  • Emergency shutdown and safety isolation sensor setups

Ordering Information

Part Type Designation Alternative Designation Compatible System Cable
F 3236 F3236 Z 7116/3236/..

Technical Specifications

Input Parameters

Parameter Value
Number of Inputs 16 channels
Input Type 1-signal, 6 mA (including cable plug) or mechanical contact 24 V
Switching Time typ. 8 ms

Operating Power Requirements

Parameter Value
5 V DC Supply Current 120 mA
24 V DC Supply Current 200 mA

Mechanical Properties

Parameter Value
Manufacturer HIMA Paul Hildebrandt GmbH + Co KG
Space Requirement 4 TE
Connection Interface Front cable plug connector

Connections/Interfaces

Connector Pin Function Colour
d2 Channel 1 Connection ws
d4 Channel 2 Connection br
d6 Channel 3 Connection gn
d8 Channel 4 Connection ge
d10 Channel 5 Connection gr
d12 Channel 6 Connection rs
d14 Channel 7 Connection bl
d16 Channel 8 Connection rt
d18 Channel 9 Connection sw
d20 Channel 10 Connection vio
d22 Channel 11 Connection ws-br

Installation Guidelines

  • Module Insertion: Slide the hardware card carefully into the specified rack position along the chassis guide tracks, confirming the 4 TE space requirement constraints are met.
  • Cable Interface: Connect the specific system cable plug matching the Z 7116/3236/.. standard directly to the front faceplate interface receptacle.
  • Signal Line Management: Group and route the multi-core input lines cleanly toward marshalling cabinets to avoid ambient electromagnetic coupling.

Compliance and Certifications

  • CE Mark
  • Requirement Class AK 1 to 6
  • DNV Type Approval (Certificate No. TAA000032E)
  • Environmental Categories: Temperature: B (from 0 Celsius), Humidity: B, Vibration: A, EMC: B
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

HIMA F 3236 HIQuad X 16-Channel Digital Input Module

What diagnostic functions are performed automatically during operation?

The module automatically runs full functional checks covering input cross-talking via a walking-zero test routine and monitors the status of internal filter capacitors.

What are the specific operational current draws for this device?

The hardware draws a typical operating current of 120 mA from the 5 V DC line and 200 mA from the 24 V DC power line.

Which specific system cable configuration is required for front connection?

The front cable plug connector requires the standard system cable interface variant designated as Z 7116/3236/..

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
Germany
Power source
DC Power

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...