Description

The HIMA F3349 is a digital output module engineered for the H41q and H51q safety-related automation systems. Designed to maximize process availability, the module features a channel-by-channel shutdown mechanism. In the event of a single channel failure, only the affected channel is isolated and shut down, while all other healthy channels continue to operate without interruption. This localized fault tolerance ensures continuous production and system stability. The device integrates seamlessly into the 2oo4D/QMR (Quadruple Modular Redundant) architecture of the H41q/H51q systems and is configured using the IEC-61131-3 compliant ELOP II engineering tool.

Features

  • Channel-by-channel fault isolation and shutdown
  • Maintains active operation of healthy channels during a single-channel fault
  • Increases overall process availability and system fault tolerance
  • Fully compatible with HIMA H41q and H51q safety system architectures
  • Supports online module replacement without process interruption
  • Configurable via ELOP II software with drag-and-drop functionality

Applications

  • Emergency shut-down systems (ESD)
  • Burner management systems (BMS)
  • Fire and gas monitoring systems (F&G)
  • High-integrity pressure protection systems (HIPPS)
  • Chemical and petrochemical process automation
  • Offshore drilling platform safety circuits

Technical Specifications

Parameter Specification
System Compatibility H41q/H51q Systems
Architecture 2oo4D/QMR (Quadruple Modular Redundant)
Safety Integrity Level Up to SIL 3 / AK 6 (in mono-configuration)
Module Replacement Online replacement supported
Programming System ELOP II (IEC 61131-3 compliant)

Installation Guidelines

  • Install the device within standard 19-inch subracks designated for H41q or H51q systems.
  • The module supports online replacement; defective units can be swapped during active operation without stopping the system.
  • Perform all configuration, diagnostics, and logic testing offline or online using the ELOP II engineering tool.
  • Ensure proper grounding and shielding protocols are followed as per standard HIMA backplane installation requirements.

Compliance and Certifications

  • IEC 61508 to SIL 3
  • DIN V 19250 to AK 6
  • EN 954-1 to category 4
  • prEN 50156
  • NFPA 8501, NFPA 8502, NFPA 72
  • EN 54-2
  • EN 61000, EN 50082-2, EN 50081-2, EN 61131-2
  • ATEX 94/9/EG, EN 1127-1
  • Factory Mutual (FM)
  • CSA
  • GOST R

FAQ

What happens if one channel fails on the module?

The device features channel-by-channel shutdown. If one channel fails, only that specific channel is shut down and isolated, allowing all other channels to continue operating without failure to increase process availability.

Can the device be replaced while the system is running?

Yes, the module supports online replacement. It can be replaced safely during operation without causing an interruption to the active process.

Which software is required to configure the device?

The module is configured using the ELOP II engineering tool, which is IEC-61131-3 compliant and provides full-graphics programming, offline simulation, and online logic testing.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

HIMA F3349 H41q/H51q System Digital Output Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
Germany
Power source
DC Power

Technical knowledge

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.

Securing Remote PLC Access Beyond the VPN

A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...