1 of 1

Honeywell 05704-A-0121 Quad Relay Interface Card

Honeywell 05704-A-0121 Quad Relay Interface Card

Only 4 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 05704-A-0121

  • Country of origin:United States

  • Product Type: Relay Interface Modules

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Honeywell 05704-A-0121 is a high-reliability Quad Relay Interface Card designed to facilitate essential signal routing between field sensors and primary control cards. This interface module supports four individual channels, providing flexible control configurations through selectable relay operations. With its robust relay contact ratings and compact form factor, the 05704-A-0121 is ideal for industrial monitoring systems requiring precise, configurable sensor-to-controller interfacing.

Features

  • Quad-channel architecture: Supports connections for up to four sensors.
  • Configurable Relay Operation: Selectable between Latching/Non-Latching and Energized/De-energized states to suit specific system safety or logic requirements.
  • High-capacity relay contacts: Rated for 5A at 110V/250V AC or 32V DC (non-inductive).
  • Compact design: Optimized for standard control panel footprints with a width of 25 mm.

Applications

  • Industrial gas and flame detection systems
  • Sensor signal processing in safety-critical loops
  • PLC and DCS input interface management
  • Automated relay switching for alarm or shutdown circuits

Technical Specifications

Feature Specification
Manufacturer Honeywell
Part Number 05704-A-0121
Product Type Quad Relay Interface Card
Power Consumption 1W (typical) / 1.7W (maximum)
Relay Configuration 4 x SPCO
Contact Rating (AC) 5A at 110V/250V AC (non-inductive)
Contact Rating (DC) 5A at 32V DC (non-inductive)
Field Terminals 2.5 mm (14 AWG)
Dimensions 132mm H x 25mm W x 119mm D
Weight 230 g
Shipping Weight 1.5 Kg

Installation Guidelines

  • Ensure the card is installed in a clean, dry environment within the control cabinet to prevent relay contact oxidation.
  • Verify that the total load connected to the relay contacts does not exceed the specified non-inductive ratings to prevent arcing.
  • Configure the Latching/Non-Latching and Energized/De-energized jumpers or switches according to your system's specific fail-safe requirements before applying power.
  • Use 2.5 mm (14 AWG) wiring for field terminals to ensure mechanical stability and correct current-carrying capacity.
  • Maintain proper separation between low-voltage signal wiring and high-voltage AC lines to prevent crosstalk and EMI.

What is the primary function of the 05704-A-0121?

This module acts as an interface card to provide connections between four sensors and a central control card.

Can the relay operation be customized?

Yes, the relay operation is selectable between Latching/Non-Latching and Energized/De-energized states.

What is the relay contact rating?

The relays are rated for 5A at 110V/250V AC or 5A at 32V DC (non-inductive).

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
United States

Recently Viewed Products

Technical knowledge

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...