Honeywell

Honeywell 51195199-050 TDC 3000 RG-11 Coaxial Trunk Cable Set

SKU 51195199-050

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: 51195199-050

  • Country of origin:United States

  • Product Type: Coaxial Cable Assemblies

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Engineered for high-integrity industrial communication networks, the Honeywell 51195199-050 is a premium 50-meter RG-11 coaxial trunk cable set. Also cataloged under the model code MU-NKT050, this pre-terminated cable assembly is designed specifically for demanding process control environments. It serves as a vital backbone link, typically deployed within Honeywell TDC 3000 Universal Control Networks (UCN) and legacy coaxial DCS architectures to ensure reliable data transmission over long physical distances.

The heavy-duty RG-11 construction provides superior signal attenuation characteristics compared to standard RG-6 coax, making it the preferred choice for trunk links. With robust electromagnetic shielding and high-integrity pre-installed connectors, this cable set maintains signal cleanless and system uptime in electrically noisy, high-voltage industrial facilities.

Features

  • Pre-terminated connectors ensure consistent impedance matching and straightforward, plug-and-play installation.
  • Heavy-gauge RG-11 coaxial design minimizes signal attenuation over the 50-meter span.
  • High-density shielding provides exceptional resistance to electromagnetic interference (EMI) and radio frequency interference (RFI).
  • Durable industrial-grade outer jacket protects the internal conductors from mechanical wear, moisture, and environmental degradation in cable trays or conduits.
  • Fully compatible with legacy Honeywell TDC 3000 and Experion PKS UCN coaxial networks.

Applications

  • Honeywell TDC 3000 Universal Control Network (UCN) installations
  • Industrial coaxial backbone communication links
  • Power generation, oil and gas, and chemical processing automation systems
  • DCS and PLC communication networks requiring heavy-duty RG-11 media

Technical Specifications

ParameterValue
Manufacturer Honeywell
Part Number/Model 51195199-050
Model Code MU-NKT050
Cable Type RG-11 Coaxial
Length 50 meters
Application Industrial Control Network Trunk Cable Set
Shipping Weight 2.0 kg

Installation Guidelines

  • Observe the standard minimum bending radius for RG-11 coaxial cables during routing to prevent internal conductor damage and signal impedance changes.
  • Avoid installing the trunk cable in close parallel proximity to high-voltage power lines or variable frequency drive (VFD) output cables.
  • Ensure that all connector couplings are fully tightened and secured against vibration to prevent intermittent network dropouts.
  • Keep cable ends protected from dust, moisture, and chemical exposure prior to final installation.

FAQ

What is the primary function of the Honeywell 51195199-050 cable set?

The Honeywell 51195199-050 (MU-NKT050) is a 50-meter pre-terminated RG-11 coaxial trunk cable set designed for industrial communication networks, such as the Honeywell TDC 3000 Universal Control Network (UCN).

Are the connectors pre-installed on this cable set?

Yes, this cable assembly comes pre-terminated with high-quality connectors to ensure proper impedance and reliable signal integrity out of the box.

What is the difference between this cable and standard RG-6 coaxial cables?

RG-11 is a thicker, lower-loss coaxial cable compared to RG-6. It features lower signal attenuation over longer distances, making it highly suitable for industrial trunk lines.

Does this cable set correspond to the part number MU-NKT050?

Yes, MU-NKT050 is the Honeywell model code associated directly with the 51195199-050 physical part number.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Designing Power and Communication Redundancy

Design control-system redundancy by mapping shared dependencies, separating power and network paths, defining failover behavior, exposing degraded operation, and proof-testing every tolerated fault.

Troubleshooting Industrial Control Cabinets Systematically

A structured control-cabinet troubleshooting method covering safe work, drawings, power paths, branch protection, DC supplies, return circuits, PLC outputs, fault records and repair verification.

Measuring Voltage in Industrial Control Circuits

A practical voltage-testing guide for industrial control panels, covering reference points, meter selection, live-dead-live checks, voltage drop, ghost voltage, stored energy and intermittent faults.

Building a Verifiable Lockout Tagout Procedure

A practical lockout tagout guide covering hazardous-energy identification, isolation, stored-energy control, verification, group work, temporary testing, restoration, inspections and audits.

Designing Compressed-Air Preparation at the Machine

A field guide to point-of-use compressed-air preparation covering filters, regulators, drains, dryers, lubrication, pressure loss, isolation, monitoring, commissioning and leak testing.

Selecting Pneumatic Valve Actuation and Safe States

A practical guide to manual, pilot and solenoid pneumatic valves, covering port functions, monostable and bistable behavior, PLC outputs, safe states, commissioning and fault diagnosis.