Honeywell 51202341-102 Experion PKS I/O Link Cable

SKU 51202341-102

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: 51202341-102

  • Country of origin:United States

  • Product Type: I/O Link Cable

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 400g

  • Dimensions: 14.0 x 14.0 x 7.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Honeywell 51202341-102 is an I/O link cable engineered for the Honeywell Experion Process Knowledge System (PKS) architecture. This specialized communication cable establishes physical connectivity between distributed control system hardware nodes, including controller input/output expansion racks and interface modules.

Designed to maintain signal integrity in high-noise industrial facilities, the 51202341-102 ensures deterministic data transfer across the automation network. Its physical construction isolates internal conductors against electromagnetic interference (EMI) and radio frequency interference (RFI) typically generated by nearby variable frequency drives and high-voltage power lines.

Features

  • Engineered specifically for Honeywell Experion PKS system architecture and network topologies
  • Shielded internal conductor design minimizes electromagnetic and radio frequency interference
  • Precision-molded connectors ensure secure mechanical insertion and prevent accidental disconnection
  • Supports continuous data transmission for critical distributed control loops

Applications

  • Experion PKS controller to I/O rack communication links
  • Distributed control system hardware network expansion
  • Process automation system signal transfer and node interconnection
  • Control room to remote marshalling cabinet data routing

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Product Series Experion PKS
Module Type I/O Link Cable
Catalog Number 51202341-102
System Compatibility Honeywell Experion C300, Series C, and compatible DCS nodes
Country of Origin United States

FAQ

What control system is the Honeywell 51202341-102 designed for?

The 51202341-102 is designed specifically for Honeywell Experion PKS distributed control system architectures to connect controllers and I/O expansion hardware.

How does the 51202341-102 cable handle electrical interference?

The cable incorporates shielded internal conductors that mitigate electromagnetic interference (EMI) and radio frequency interference (RFI) in harsh industrial environments.

Can the 51202341-102 be used for hot-swapping I/O modules?

System hardware manuals dictate hot-swapping procedures; however, the cable itself maintains physical link stability during rack-level expansions and maintenance operations when executed per Honeywell guidelines.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.