  • Product No.: 51304672-150

  • Country of origin:United States

  • Product Type: Analog Output Modules

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 600g

  • Dimensions: 2.9 x 31.9 x 27.8 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Honeywell 51304672-150 is an analog output main board designed specifically for integration within Honeywell TDC 3000 distributed control system architectures. This core system component serves to process and transmit control commands from the central processing environment to field actuators, control valves, and other continuous control devices, ensuring precise regulation of industrial processes.

Engineered for deployment in rigorous plant environments, the 51304672-150 module mounts directly into standard TDC 3000 node chassis housings, establishing reliable internal bus communication and power distribution. It executes real-time digital-to-analog conversion tasks to drive critical final control elements across continuous processing applications.

Features

  • Native component of the Honeywell TDC 3000 distributed control system architecture
  • Executes high-accuracy digital-to-analog conversion for industrial control loops
  • Directly mounts into standard TDC 3000 node slots with secure backplane interfacing
  • Designed for continuous operation in demanding industrial process environments
  • Facilitates streamlined system diagnostics and maintenance reporting

Applications

  • Oil and gas upstream extraction and downstream refining facilities
  • Chemical and petrochemical continuous processing plants
  • Power generation plant turbine and boiler control systems
  • Pulp and paper manufacturing process automation

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Exact Model 51304672-150
Product Type Analog Output Main Board
Product Series TDC 3000
System Compatibility Honeywell TDC 3000 DCS
Country of Origin United States

Installation Guidelines

  1. Verify that the replacement part number 51304672-150 matches the exact system architecture and slot requirement before proceeding.
  2. De-energize the target TDC 3000 node chassis or isolate the specific slot power prior to hardware handling.
  3. Inspect the module edge connectors and backplane pins for any debris, contamination, or mechanical damage.
  4. Align the analog output main board carefully with the designated guide rails and push firmly to seat it fully into the backplane connector.
  5. Secure any retention fasteners or latching mechanisms provided on the chassis.
  6. Restore power to the node and verify proper module initialization and communication status via the Experion or TDC operator station.

FAQ

What system is the Honeywell 51304672-150 designed for?

The Honeywell 51304672-150 is engineered specifically for deployment within Honeywell TDC 3000 distributed control system (DCS) architectures.

What is the primary function of the 51304672-150 board?

The Honeywell 51304672-150 functions as an analog output main board, converting controller commands into precise analog signals to drive industrial actuators and control valves.

Where is the Honeywell 51304672-150 manufactured?

The Honeywell 51304672-150 is manufactured in the United States as part of the standard TDC 3000 hardware production line.

How is the 51304672-150 installed into the control system?

The Honeywell 51304672-150 mounts directly into a designated slot within a standard TDC 3000 node chassis, interfacing with the internal backplane for power and data communication.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.