Honeywell

Honeywell FSC 10024/H/I 26901 Enhanced Communication Module

SKU 10024/H/I

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: 10024/H/I

  • Country of origin:United States

  • Product Type: Communication Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 220 x 180 x 25 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Honeywell 10024/H/I (Model Type 26901) is an enhanced communication and interface module engineered specifically for the Honeywell Fail-Safe Control (FSC) safety system series. Designed to provide critical connectivity between systems, this rack-mounting card enables seamless inter-system data transfer and external network interface capabilities required in high-integrity industrial environments.

Operating on a 5V DC internal power rail with a typical current draw of 675mA, the module houses an integrated central processor along with dual front-panel serial ports. The port configuration consists of port A supporting RS-232 communication and port B configured for differential RS-422/RS-485 industrial links. This dual-interface architecture allows the FSC safety controller to interface concurrently with distributed control systems (DCS), supervisory control and data acquisition (SCADA) platforms, or dedicated operator stations without sacrificing system execution speed.

Features

  • Dual Serial Architecture: Equipped with two front-panel DB9 connectors (Ports A and B) to manage isolated serial communication channels simultaneously.
  • Multi-Protocol Support: Supports RS-232 link protocols on Port A alongside RS-422 and RS-485 differential links on Port B for versatile field connectivity.
  • Integrated Processing: Features built-in central processor (CP) logic to handle communication overhead, offloading message parsing from the central FSC processing modules.
  • Direct Rack Integration: Form-factor designed for direct insertion into standard FSC Central Part system bus racks (such as 7-slot, 12-slot, or 17-slot chassis configurations).
  • Low Power Consumption: Runs off the internal system backplane supply at 5V DC drawing approximately 675mA under normal operational load.

Applications

  • DCS and Safety System Interfacing: Establishing serial Modbus or proprietary communication links between Honeywell FSC safety systems and Honeywell Experion PKS or third-party DCS networks.
  • External Device Monitoring: Connecting auxiliary industrial equipment such as local HMIs, sequence of events (SOE) recorders, and diagnostic computers to the FSC safety logic solver.
  • System-to-System Peer Data Transfer: Supporting serial links between multi-rack FSC node configurations or distributed safety system architectures across process sites.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model 10024/H/I
Model Type 26901
System Series Fail-Safe Control (FSC)
Module Type Enhanced Communication / Interface Module
Input Voltage 5V DC
Current Consumption 675mA (typical)
Front Ports 2 x DB9 Serial Connectors (Labeled A and B)
Serial Interfaces RS-232 (Port A) / RS-422 / RS-485 (Port B)
Processor Hardware Integrated Central Processor (int. CP)
Mounting Format FSC Central Part System Bus Rack Card

Connections / Interfaces

Interface Connector Type Function / Protocol Support
Port A DB9 Male/Female Front Panel Serial Communication Interface (RS-232)
Port B DB9 Male/Female Front Panel Serial Communication Interface (RS-422 / RS-485)
Backplane Bus Edge Connector 5V DC Power Input and Internal FSC Bus Link

Installation Guidelines

  1. Power Inspection: Verify system power and confirm that the backplane supply delivers stable 5V DC before inserting the card into the FSC rack chassis.
  2. Card Slot Alignment: Ensure the target rack slot on the FSC S7-BUS, S12-BUS, or S17-BUS is free of debris. Carefully align the card edges with the guide rails and press firmly to seat the backplane edge connector.
  3. Serial Cable Termination: For RS-422 or RS-485 connections on Port B, ensure proper line termination resistors are implemented across long cable runs to prevent signal reflection and data corruption.
  4. Shielding and Grounding: Connect shielded twisted-pair cables to DB9 ports, ensuring proper signal grounding techniques are applied to prevent electromagnetic interference (EMI) from affecting safety communications.

Configuration and Replacement Recommendations

  • Parameter Verification: Prior to replacing an existing module, record all serial communication parameters (baud rate, parity, data bits, stop bits, node ID) configured in the FSC engineering software.
  • Hot Swapping Precaution: Power down the slot or respect FSC rack maintenance procedures before inserting or extracting the module to protect sensitivity-critical internal logic components.
  • Commissioning Check: After installation, verify status LEDs on the front panel and initiate communication diagnostic tests from the master control station to confirm active Tx/Rx data transfer on both Port A and Port B.

FAQ

What is the function of the Honeywell 10024/H/I module in an FSC safety system?

The Honeywell 10024/H/I is an enhanced communication card that establishes serial data connections between an FSC safety system and external networks like DCS platforms, HMIs, or third-party devices. It offloads serial messaging tasks from the main safety processor using its integrated CP.

What are the serial interface specifications for Ports A and B on the 10024/H/I module?

The front panel features two DB9 serial connectors. Port A supports RS-232 communication, while Port B is configured to support RS-422 and RS-485 differential serial communications.

What power supply voltage and current ratings are required for the 10024/H/I card?

The module operates from the internal FSC backplane bus supplying 5V DC, with a typical operational current consumption of 675mA.

How does the 10024/H/I differ from other 10024 series communication modules?

Unlike versions with dual RS-232 ports (such as the 10024/F/F) or dual RS-422/485 ports (such as the 10024/I/I), the 10024/H/I variant combines an internal central processor with one RS-232 port and one RS-422/RS-485 port for hybrid serial integration.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell FSC 10024/H/I 26901 Enhanced Communication Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Technical knowledge

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.

PLC I/O Modules: Wiring, Load, and Isolation Checks

A field checklist for matching PLC digital and analog I/O to sensors, loads, commons, isolation groups, filters, and replacement settings.