Description

The Honeywell CC-TDOB01 is a 9-inch non-redundant Digital Output 24V Input Output Termination Assembly (IOTA) designed for the Honeywell Experion PKS Series C architecture. It serves as the physical interface layer connecting field-level actuators, relays, indicators, and solenoids to the corresponding Series C Digital Output 24V I/O Module (IOM).

Engineered to support up to 32 discrete channels, the assembly routes control signals and power directly to field devices through dedicated terminal block connections. The architecture supports field wiring protection mechanisms integrated with the IOM, including individual channel current monitoring and over-current shutdown features.

The board accommodates flexible system powering options, accepting both internal system power or customer-supplied external 24V DC power sources. Its non-redundant 9-inch footprint offers a compact installation footprint for standardized control cabinets in industrial automation environments.

Features

  • 32-Channel Field Termination: Provides dedicated power and return screw connections for 32 discrete 24V DC output channels across two primary terminal blocks.
  • Selective Over-Current Protection Support: Works with the digital output module to sense field shorts, automatically shutting down only the affected point while leaving non-faulted channels operational.
  • Soft Failure Diagnostic Signaling: Facilitates an Over-current Soft Failure alarm generation and switches the faulted point mode to Manual until the short circuit is resolved.
  • Thermal Protection Monitoring: Supports thermal protection alarming for field short circuit conditions exceeding 0.5A.
  • Flexible Power Source Configuration: Configurable via Terminal Block 3 to select between Honeywell internal 24V power supply or external customer-supplied 24V power.
  • Compact Non-Redundant Footprint: Standardized 9-inch Series C board profile designed for efficient cabinet space utilization.

Applications

  • Process Output Actuation: Interfacing Experion PKS Series C controllers with field solenoids, interposing relays, and control valves.
  • Industrial Plant Annunciation: Driving discrete field indicators, alarms, stack lights, and status panels.
  • Discrete System Control: Providing 24V DC switching logic for batch, continuous process, and manufacturing automation infrastructure.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model CC-TDOB01
Product Type Digital Output 24V IOTA
System Platform Experion PKS Series C
Configuration Non-Redundant
Size Profile 9-Inch
Channel Capacity 32 Channels
Field Power Supply Voltage 24V DC
Power Source Options Internal System Power / External Customer Power
Short Circuit Protection Threshold > 0.5A (Thermal Protection Alarm)
Fault Reaction Individual channel shutdown; Mode set to Manual
Terminal Blocks TB1 (Channels 1-16), TB2 (Channels 17-32), TB3 (Power Selection)

Connections / Interfaces

Interface / Terminal Block Pin / Screw Function
TB1 (Channels 1–16) Odd Screws (1, 3, ... 31) Channel Power Screws (Ch 1 to Ch 16)
  Even Screws (2, 4, ... 32) Channel Return Screws (Ch 1 to Ch 16)
TB2 (Channels 17–32) Odd Screws (1, 3, ... 31) Channel Power Screws (Ch 17 to Ch 32)
  Even Screws (2, 4, ... 32) Channel Return Screws (Ch 17 to Ch 32)
TB3 (Power Input) Screw 1 Internal 24V
  Screw 2 Internal Return
  Screw 3 External 24V
  Screw 4 External Return

Installation Guidelines

  1. Inspect the IOTA board for mechanical integrity prior to installation in the Series C cabinet.
  2. Mount the 9-inch IOTA board onto the panel rack or enclosure backplate following Series C spacing standards.
  3. Confirm whether internal or external 24V power will be utilized and wire Terminal Block 3 accordingly.
  4. Ensure proper power polarity on external supply lines to prevent module damage.
  5. Wire field devices to Terminal Blocks 1 and 2, securing positive leads to power screws and negative leads to return screws.
  6. Seat the corresponding Series C 24V Digital Output IOM firmly into the card position on the IOTA assembly.

Replacement Recommendations

  1. Verify that the replacement part number matches CC-TDOB01.
  2. Disconnect field power supplying Terminal Block 3 if using an external power source.
  3. Remove the associated I/O Module from the IOTA card connector.
  4. Label and disconnect field wiring screw terminal plugs or leads from TB1, TB2, and TB3.
  5. Unmount the degraded IOTA board, mount the new assembly, reconnect wiring plugs, and reinsert the IOM.
  6. Reapply power and verify channel diagnostic status in Experion PKS system software.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Honeywell CC-TDOB01?
The Honeywell CC-TDOB01 is a 9-inch non-redundant Input Output Termination Assembly (IOTA) designed to connect 32 field-level 24V DC discrete output devices directly to a Honeywell Experion PKS Series C Digital Output Module.
How does the Honeywell CC-TDOB01 handle field short circuits?
When a short circuit occurs on a connected channel, the output circuit senses the over-current condition, trips a thermal alarm if above 0.5A, shuts down only the affected point, switches that point's mode to Manual, and triggers an Over-current Soft Failure alarm without interrupting other channels.
Can the Honeywell CC-TDOB01 use an external 24V power supply?
Yes, Terminal Block 3 on the assembly allows selection between an internal Honeywell power supply and a customer-supplied external 24V power source. External power wiring must maintain correct polarity to prevent damage.
How many channels does the Honeywell CC-TDOB01 IOTA support?
The Honeywell CC-TDOB01 termination assembly supports up to 32 individual 24V DC digital output channels distributed across Terminal Block 1 (Channels 1–16) and Terminal Block 2 (Channels 17–32).
Reviews

CC-TDOB01

Stock & lead time on request

Call
1 of 3

Honeywell CC-TDOB01 Series C 24V Digital Output IOTA 9-Inch Non-Redundant

Only 5 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: CC-TDOB01

  • Country of origin:United States

  • Product Type: Digital Output IOTA Board

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 228.6 x 127.0 x 40.0 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Honeywell CC-TDOB01 is a 9-inch non-redundant Digital Output 24V Input Output Termination Assembly (IOTA) designed for the Honeywell Experion PKS Series C architecture. It serves as the physical interface layer connecting field-level actuators, relays, indicators, and solenoids to the corresponding Series C Digital Output 24V I/O Module (IOM).

Engineered to support up to 32 discrete channels, the assembly routes control signals and power directly to field devices through dedicated terminal block connections. The architecture supports field wiring protection mechanisms integrated with the IOM, including individual channel current monitoring and over-current shutdown features.

The board accommodates flexible system powering options, accepting both internal system power or customer-supplied external 24V DC power sources. Its non-redundant 9-inch footprint offers a compact installation footprint for standardized control cabinets in industrial automation environments.

Features

  • 32-Channel Field Termination: Provides dedicated power and return screw connections for 32 discrete 24V DC output channels across two primary terminal blocks.
  • Selective Over-Current Protection Support: Works with the digital output module to sense field shorts, automatically shutting down only the affected point while leaving non-faulted channels operational.
  • Soft Failure Diagnostic Signaling: Facilitates an Over-current Soft Failure alarm generation and switches the faulted point mode to Manual until the short circuit is resolved.
  • Thermal Protection Monitoring: Supports thermal protection alarming for field short circuit conditions exceeding 0.5A.
  • Flexible Power Source Configuration: Configurable via Terminal Block 3 to select between Honeywell internal 24V power supply or external customer-supplied 24V power.
  • Compact Non-Redundant Footprint: Standardized 9-inch Series C board profile designed for efficient cabinet space utilization.

Applications

  • Process Output Actuation: Interfacing Experion PKS Series C controllers with field solenoids, interposing relays, and control valves.
  • Industrial Plant Annunciation: Driving discrete field indicators, alarms, stack lights, and status panels.
  • Discrete System Control: Providing 24V DC switching logic for batch, continuous process, and manufacturing automation infrastructure.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model CC-TDOB01
Product Type Digital Output 24V IOTA
System Platform Experion PKS Series C
Configuration Non-Redundant
Size Profile 9-Inch
Channel Capacity 32 Channels
Field Power Supply Voltage 24V DC
Power Source Options Internal System Power / External Customer Power
Short Circuit Protection Threshold > 0.5A (Thermal Protection Alarm)
Fault Reaction Individual channel shutdown; Mode set to Manual
Terminal Blocks TB1 (Channels 1-16), TB2 (Channels 17-32), TB3 (Power Selection)

Connections / Interfaces

Interface / Terminal Block Pin / Screw Function
TB1 (Channels 1–16) Odd Screws (1, 3, ... 31) Channel Power Screws (Ch 1 to Ch 16)
  Even Screws (2, 4, ... 32) Channel Return Screws (Ch 1 to Ch 16)
TB2 (Channels 17–32) Odd Screws (1, 3, ... 31) Channel Power Screws (Ch 17 to Ch 32)
  Even Screws (2, 4, ... 32) Channel Return Screws (Ch 17 to Ch 32)
TB3 (Power Input) Screw 1 Internal 24V
  Screw 2 Internal Return
  Screw 3 External 24V
  Screw 4 External Return

Installation Guidelines

  1. Inspect the IOTA board for mechanical integrity prior to installation in the Series C cabinet.
  2. Mount the 9-inch IOTA board onto the panel rack or enclosure backplate following Series C spacing standards.
  3. Confirm whether internal or external 24V power will be utilized and wire Terminal Block 3 accordingly.
  4. Ensure proper power polarity on external supply lines to prevent module damage.
  5. Wire field devices to Terminal Blocks 1 and 2, securing positive leads to power screws and negative leads to return screws.
  6. Seat the corresponding Series C 24V Digital Output IOM firmly into the card position on the IOTA assembly.

Replacement Recommendations

  1. Verify that the replacement part number matches CC-TDOB01.
  2. Disconnect field power supplying Terminal Block 3 if using an external power source.
  3. Remove the associated I/O Module from the IOTA card connector.
  4. Label and disconnect field wiring screw terminal plugs or leads from TB1, TB2, and TB3.
  5. Unmount the degraded IOTA board, mount the new assembly, reconnect wiring plugs, and reinsert the IOM.
  6. Reapply power and verify channel diagnostic status in Experion PKS system software.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell CC-TDOB01 Series C 24V Digital Output IOTA 9-Inch Non-Redundant

What is the primary function of the Honeywell CC-TDOB01?

The Honeywell CC-TDOB01 is a 9-inch non-redundant Input Output Termination Assembly (IOTA) designed to connect 32 field-level 24V DC discrete output devices directly to a Honeywell Experion PKS Series C Digital Output Module.

How does the Honeywell CC-TDOB01 handle field short circuits?

When a short circuit occurs on a connected channel, the output circuit senses the over-current condition, trips a thermal alarm if above 0.5A, shuts down only the affected point, switches that point's mode to Manual, and triggers an Over-current Soft Failure alarm without interrupting other channels.

Can the Honeywell CC-TDOB01 use an external 24V power supply?

Yes, Terminal Block 3 on the assembly allows selection between an internal Honeywell power supply and a customer-supplied external 24V power source. External power wiring must maintain correct polarity to prevent damage.

How many channels does the Honeywell CC-TDOB01 IOTA support?

The Honeywell CC-TDOB01 termination assembly supports up to 32 individual 24V DC digital output channels distributed across Terminal Block 1 (Channels 1–16) and Terminal Block 2 (Channels 17–32).

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...