Honeywell

Honeywell 51305072-100 LCN I/O Board CLCN-A/B

SKU 51305072-100

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: 51305072-100
  • Origin United States
  • Product Type: LCN I/O Boards
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 0.18 kg
  • Dimensions: 3cm x 13.5cm x 23.8cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The Honeywell 51305072-100 is an LCN I/O board designed specifically for integration within legacy TDC 3000 distributed control system architectures. This specialized printed circuit assembly serves as a critical interface module, facilitating robust communication and data exchange across the Local Control Network (LCN). Engineered to meet rigorous industrial demands, it ensures reliable operational continuity for process control environments that rely on traditional Honeywell automation infrastructure.

As a designated LCN interface component, the 51305072-100 module is built to handle specific network traffic and protocol handling requirements inherent to TDC 3000 systems. It mounts directly into standard Honeywell node chassis slots, maintaining mechanical and electrical compatibility with existing system backplanes. Maintenance engineers and system integrators utilize this exact part number for direct hardware replacement during lifecycle sustainment and upkeep of mature industrial control networks.

Features

  • Engineered specifically for Honeywell TDC 3000 LCN architecture compatibility
  • Supports reliable communication and data routing across the Local Control Network
  • Direct replacement part matching original form, fit, and functional pinouts
  • Designed for standard chassis mounting within node cabinets
  • Built to industrial environmental tolerances for continuous process control duty

Applications

  • TDC 3000 Distributed Control System (DCS) maintenance and repair
  • Local Control Network (LCN) node communication expansion and upkeep
  • Legacy continuous process manufacturing plants
  • Petrochemical and refining control room system sustainment

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Exact Model 51305072-100 (CLCN-A/B)
Product Type LCN I/O Board
System Platform TDC 3000 / LCN
Country of Origin United States
Dimensions 23.8 x 13.5 x 3.0 cm
Net Weight 0.18 kg
Mounting Chassis slot (Standard LCN node)

Installation Guidelines

  1. Verify that the replacement part number 51305072-100 matches the failed module exactly.
  2. De-energize the target node chassis and follow standard plant lockout/tagout safety procedures before handling hardware.
  3. Inspect the replacement board and backplane slot connectors for any debris, bent pins, or oxidation.
  4. Carefully slide the LCN I/O board into the designated chassis guide rails and seat it firmly into the backplane connector.
  5. Secure any retention fasteners or locking levers per standard Honeywell hardware installation practices.
  6. Restore power to the chassis and verify proper node communication LEDs and system diagnostic status through the TDC 3000 console.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What system architecture is the Honeywell 51305072-100 LCN I/O Board designed for?
The Honeywell 51305072-100 LCN I/O Board is specifically engineered for integration within legacy Honeywell TDC 3000 distributed control system architectures. This specialized interface module facilitates robust communication and data exchange across the Local Control Network. It ensures reliable operational continuity for demanding industrial process control environments.
How do I install the Honeywell 51305072-100 replacement module?
To install the Honeywell 51305072-100 replacement module, first de-energize the target node chassis and follow strict plant lockout/tagout safety procedures. Carefully slide the board into the designated chassis guide rails, seating it firmly into the backplane connector before securing any retention fasteners. Finally, restore power and verify proper node communication status through your TDC 3000 operator console.
What are the physical dimensions and weight of this LCN board?
The Honeywell 51305072-100 LCN I/O Board features physical dimensions of approximately 23.8 x 13.5 x 3.0 cm. It has a lightweight design with a net weight of 0.18 kg, optimizing it for standard chassis slot mounting. These precise dimensions ensure a seamless drop-in replacement matching the original form and fit.
What are the primary industrial applications for the Honeywell 51305072-100?
The Honeywell 51305072-100 is primarily utilized for TDC 3000 Distributed Control System maintenance, repair, and legacy system sustainment. It supports Local Control Network node communication upkeep within continuous process manufacturing plants, petrochemical facilities, and refining control rooms. Maintenance engineers rely on this exact part number to ensure uninterrupted network traffic handling.
Reviews

51305072-100

Stock & lead time on request

Call
1 of 3

Honeywell 51305072-100 LCN I/O Board CLCN-A/B

Only 4 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 51305072-100

  • Country of origin:United States

  • Product Type: LCN I/O Boards

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 180g

  • Dimensions: 3cm x 13.5cm x 23.8cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The Honeywell 51305072-100 is an LCN I/O board designed specifically for integration within legacy TDC 3000 distributed control system architectures. This specialized printed circuit assembly serves as a critical interface module, facilitating robust communication and data exchange across the Local Control Network (LCN). Engineered to meet rigorous industrial demands, it ensures reliable operational continuity for process control environments that rely on traditional Honeywell automation infrastructure.

As a designated LCN interface component, the 51305072-100 module is built to handle specific network traffic and protocol handling requirements inherent to TDC 3000 systems. It mounts directly into standard Honeywell node chassis slots, maintaining mechanical and electrical compatibility with existing system backplanes. Maintenance engineers and system integrators utilize this exact part number for direct hardware replacement during lifecycle sustainment and upkeep of mature industrial control networks.

Features

  • Engineered specifically for Honeywell TDC 3000 LCN architecture compatibility
  • Supports reliable communication and data routing across the Local Control Network
  • Direct replacement part matching original form, fit, and functional pinouts
  • Designed for standard chassis mounting within node cabinets
  • Built to industrial environmental tolerances for continuous process control duty

Applications

  • TDC 3000 Distributed Control System (DCS) maintenance and repair
  • Local Control Network (LCN) node communication expansion and upkeep
  • Legacy continuous process manufacturing plants
  • Petrochemical and refining control room system sustainment

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Exact Model 51305072-100 (CLCN-A/B)
Product Type LCN I/O Board
System Platform TDC 3000 / LCN
Country of Origin United States
Dimensions 23.8 x 13.5 x 3.0 cm
Net Weight 0.18 kg
Mounting Chassis slot (Standard LCN node)

Installation Guidelines

  1. Verify that the replacement part number 51305072-100 matches the failed module exactly.
  2. De-energize the target node chassis and follow standard plant lockout/tagout safety procedures before handling hardware.
  3. Inspect the replacement board and backplane slot connectors for any debris, bent pins, or oxidation.
  4. Carefully slide the LCN I/O board into the designated chassis guide rails and seat it firmly into the backplane connector.
  5. Secure any retention fasteners or locking levers per standard Honeywell hardware installation practices.
  6. Restore power to the chassis and verify proper node communication LEDs and system diagnostic status through the TDC 3000 console.
Loading product navigation…

What system architecture is the Honeywell 51305072-100 LCN I/O Board designed for?

The Honeywell 51305072-100 LCN I/O Board is specifically engineered for integration within legacy Honeywell TDC 3000 distributed control system architectures. This specialized interface module facilitates robust communication and data exchange across the Local Control Network. It ensures reliable operational continuity for demanding industrial process control environments.

How do I install the Honeywell 51305072-100 replacement module?

To install the Honeywell 51305072-100 replacement module, first de-energize the target node chassis and follow strict plant lockout/tagout safety procedures. Carefully slide the board into the designated chassis guide rails, seating it firmly into the backplane connector before securing any retention fasteners. Finally, restore power and verify proper node communication status through your TDC 3000 operator console.

What are the physical dimensions and weight of this LCN board?

The Honeywell 51305072-100 LCN I/O Board features physical dimensions of approximately 23.8 x 13.5 x 3.0 cm. It has a lightweight design with a net weight of 0.18 kg, optimizing it for standard chassis slot mounting. These precise dimensions ensure a seamless drop-in replacement matching the original form and fit.

What are the primary industrial applications for the Honeywell 51305072-100?

The Honeywell 51305072-100 is primarily utilized for TDC 3000 Distributed Control System maintenance, repair, and legacy system sustainment. It supports Local Control Network node communication upkeep within continuous process manufacturing plants, petrochemical facilities, and refining control rooms. Maintenance engineers rely on this exact part number to ensure uninterrupted network traffic handling.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Diagnosing 24 VDC Power Supplies Without Chasing Ghost Faults

A dead control cabinet does not automatically mean a failed power supply. This field guide uses input, no-load, loaded, ripple, wiring, and protection checks to separate source faults from downstream...

A Practical Signal Chain for Industrial Measurement and Control

Reliable control begins before the PLC executes a loop. This engineering guide follows the signal chain from sensing and conditioning to transmission, control action, final elements, calibration, and...

Modbus on Plant Networks: Frames, Registers, and Design Limits

Modbus remains widely deployed because its data model is simple, not because every implementation is simple. This guide explains frames, register mapping, timing, diagnostics, and the design limits...

Inside the PLC CPU: Scan Cycles, Memory, and Selection

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit