Honeywell

Honeywell 900C70-0460 ControlEdge HC900 CPU Module

SKU 900C70-0460

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: 900C70-0460

  • Country of origin:United States

  • Product Type: PLC CPU Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 137 mm x 38.1 mm x 127 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Executing process, logic, and sequential control loops within industrial thermal and process applications, the Honeywell 900C70-0460 serves as the central processing unit for the ControlEdge HC900 platform. This controller module is engineered for high-density analog processing, providing precise loop control and flexible integration options for both single and redundant system architectures. Leveraging advanced Ethernet capability, the device interfaces seamlessly with supervisory systems and remote HMI terminals to maintain deterministic communication across demanding plant networks.

Features

  • Dual Ethernet Ports: Supports redundant physical connections for robust supervisor/host and peer-to-peer field communications.
  • High-Capacity Process Loops: Manages complex PID algorithms, setpoint programming, and multi-variable logic handling.
  • Redundancy Control Option: Easily integrates into dual-CPU chassis systems to prevent unexpected runtime downtime.
  • Flash Memory Storage: Retains configuration settings and firmware parameters during power loss events without requiring battery backup.
  • Modular Rack Assembly: Installs directly into standard HC900 series bases for rapid, secure backplane slot alignment.

Applications

  • Thermal Process Control: Ideal for industrial kilns, environmental chambers, and multi-zone heat treating systems.
  • Water and Wastewater Treatment: Oversees chemical dosing, filtration sequencing, and remote pump station monitoring.
  • Combustion Control Systems: Regulates boiler fuel-to-air ratios, burner management sequences, and stack gas monitoring.
  • Specialty Chemical Processing: Manages complex batch processing runs requiring highly repeatable timing and thermal cycles.

Technical Specifications

Parameter Specification Value
Manufacturer Honeywell
Model Series ControlEdge HC900
Model Number 900C70-0460
Module Type Central Processing Unit (CPU)
Ethernet Ports 2 x RJ-45 (10/100 Base-T)
Serial Interfaces RS-485 / RS-232 Configuration Ports
Operating Temperature 0 to 60 degC
Storage Temperature -40 to 85 degC
Humidity Limits 5% to 95% RH, non-condensing
Module Weight 0.4 kg
Shipping Weight (Calculated) 1.2 kg
Dimensions (H x W x D) 137 mm x 38.1 mm x 127 mm

Connections and Interfaces

Connector / Terminal Function / Circuit Assignment
Ethernet Port 1 (Top RJ-45) Network Link / Modbus TCP Host Communication
Ethernet Port 2 (Bottom RJ-45) Peer-to-Peer Controller Networking / HMI Connection
RS-485 Serial Port Modbus RTU Master/Slave Multi-Drop Network
RS-232 Serial Port Local Configuration PC (HCD Software Interface)

Empirical Engineering Insights

Alternative Models & Compatibility

The 900C70-0460 is part of the upgraded ControlEdge HC900 C70 hardware family. It offers direct backwards program compatibility with older 900C71/C72 chassis layouts, provided that the system configuration software (Hybrid Control Designer) is updated to support the targeted firmware version. Note that mixing older C50 CPU variants with C70 redundant sets in the same physical rack is not permitted and will trigger a backplane mismatch fault.

Application Pitfalls & Engineering Notes

When deploying the CPU in non-ventilated control panels, ensure that adequate vertical clearances are maintained. Thermal buildup around the CPU can limit processing stability and lead to self-protective watchdog timeouts. System power sizing must account for the primary backplane draw; the 900C70-0460 should always be paired with a fully rated 900P01 or 900P02 power supply to prevent transient brownouts under high I/O configurations.

Commissioning & Wiring Tips

Always route the Ethernet communication lines separately from high-voltage AC lines to prevent magnetic noise induction. For the serial RS-485 interfaces, a high-quality shielded twisted pair (STP) cable is required, with a 120-ohm terminating resistor installed at the physical ends of the trunk line. During physical address configuration, verify that IP addresses configured inside the HCD software do not conflict with existing SCADA or DCS nodes on the same plant subnet.

Installation Guidelines

CRITICAL WARNING: De-energize all primary and auxiliary power supplies feeding the rack assembly before attempting installation or removal of the CPU module. Failure to isolate power can result in permanent module damage, backplane failure, or unintended actuation of physical process equipment.
1

Align the upper and lower plastic guides of the CPU module with the designated CPU slot on the main baseboard rack.

2

Gently slide the module straight into the slot until the backplane connector pin matrix is fully engaged and flush.

3

Secure the module fastening screws on the top and bottom of the front plate to a torque of 0.5 Nm (approx. 4.4 in-lbs).

4

Connect the dedicated communication and ground cables, ensuring the shielding wires are terminated correctly at the ground bar.

FAQ

What configuration software is required for the 900C70-0460 module?

This module is configured using the Honeywell HC900 Hybrid Control Designer (HCD) software utility.

Does this processor module support hot-standby CPU redundancy?

Yes, the 900C70-0460 is fully capable of redundant processing when installed in a dedicated redundant CPU base rack.

What is the standard operating temperature range for this controller?

The CPU is rated for operation within an ambient temperature range of 0 to 60 degC.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.

Securing Remote PLC Access Beyond the VPN

A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...