Honeywell

Honeywell CC-GAIX11 Analog Input GI/IS Redundant IOTA

SKU CC-GAIX11

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: CC-GAIX11
  • Origin United States
  • Product Type: Redundant Analog Input IOTA
  • Payment: T/T, Western Union
  • Weight: 0.65 kg
  • Dimensions: 310 x 160 x 60 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell CC-GAIX11 Analog Input GI/IS Redundant IOTA

Quantity

Product Description

Description

The Honeywell CC-GAIX11 is a Redundant Analog Input GI/IS IOTA (Galvanic Isolation / Intrinsically Safe Input Output Termination Assembly) designed for high-availability process control within the Honeywell Experion PKS Series C I/O architecture. It provides the physical and electrical interface required to land field sensor signals and route them securely to paired Series C Analog Input Modules, such as the CC-PAIH01, CC-PAIH02, CC-PAIX01, or CC-PAIX02.

Built for critical industrial operations, the CC-GAIX11 incorporates redundant IOM mounting positions directly on the board. This configuration allows two compatible Series C Analog Input Modules to operate in a parallel, redundant setup without requiring external switching hardware or additional cross-cabling. The assembly provides built-in signal conditioning and field power distribution, ensuring reliable data acquisition from 4-20mA and voltage transmitters across demanding processing environments.

Features

  • Redundant Architecture: Supports two plug-in Series C I/O modules on a single assembly for seamless hardware fault tolerance.
  • Galvanic Isolation / Intrinsically Safe (GI/IS) Support: Formed specifically to interface with galvanically isolated field circuits for safety-critical plant environments.
  • Compact 12-Inch Form Factor: Standardized 12-inch (304 mm) IOTA footprint maximizes cabinet density while providing full termination access.
  • Direct-Bus Powering: Receives primary 24 VDC operating power directly from the mounting carrier bus, eliminating extra power distribution wiring.
  • Integrated Signal Routing: Combines process signal conditioning and redundant network bus connection (I/O LINK) on a single board assembly.
  • Detachable Screw Terminals: Features two-level field wiring terminals to facilitate simplified installation, maintenance, and field loops testing.

Applications

  • Hazardous Area Field Interfacing: Integrates process transmitters installed in demanding process zones into the Experion C300 controller platform.
  • Redundant Analog Data Acquisition: Guarantees uninterrupted monitoring of critical process variables such as flow, pressure, level, and temperature.
  • DCS Cabinet Optimization: Reduces overall enclosure footprint by integrating field terminations, power distribution, and redundancy on one board.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model CC-GAIX11
Product Type Redundant Analog Input GI/IS IOTA
Series Experion Series C I/O
Compatible IOM Models CC-PAIH01, CC-PAIH02, CC-PAIX01, CC-PAIX02
Redundancy Yes (Dual IOM Slot)
Physical Size 12 inches (304 mm)
Input Channels 16 Channels
Field Signal Types 4-20 mA, 0 to 5 V, 1 to 5 V, 0.4 to 2 V
Field Power Supply 24 VDC via IOTA Carrier Bus
Field Wiring Terminals Detachable two-level terminal blocks
Maximum Wire Size 12 AWG / 2.5 mm2 stranded wire

Connections / Interfaces

Interface Function
IOM Plug-in Slots Dual mounting positions for redundant High-Level Analog Input Modules
Field Terminal Blocks Detachable 2-level screw terminals for field transmitter wiring
Carrier Power Interface Direct bus connections for 24 VDC system power entry
System I/O Link On-board routing to the Experion C300 controller network

Installation Guidelines

  1. Pre-Installation Inspection: Verify that the CC-GAIX11 assembly is undamaged and that the mounting carrier slots are clean and free of debris.
  2. Mounting: Securely mount the IOTA onto the Series C cabinet enclosure base or carrier rail, ensuring proper engagement with the 24 VDC power bus.
  3. Wiring Connections: Land field wiring on the two-level detachable terminal blocks using stranded wire up to 12 AWG (2.5 mm²). Ensure shield and signal commons are properly routed according to plant grounding guidelines.
  4. Module Insertion: Carefully align and plug the designated Analog Input Modules (e.g., CC-PAIH02 or CC-PAIX02) into the primary and redundant IOM positions on the IOTA until fully seated and locked.
  5. Power Verification: Confirm proper 24 VDC supply voltage at the carrier bus prior to commissioning control loops.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Honeywell CC-GAIX11?
The CC-GAIX11 is a 12-inch redundant Input Output Termination Assembly (IOTA) in the Honeywell Experion Series C system. It connects field analog input signals to paired Series C Analog Input Modules, providing signal routing, power distribution, and fault-tolerant operation.
Which Honeywell I/O modules plug into the CC-GAIX11 IOTA?
The CC-GAIX11 supports High-Level Analog Input Modules, including models CC-PAIH01, CC-PAIH02, CC-PAIX01, and CC-PAIX02, enabling both HART and non-HART analog data collection.
Does the CC-GAIX11 require separate redundancy control cabling?
No. Redundancy is handled directly on the CC-GAIX11 board assembly. Simply installing two compatible Analog Input Modules onto the dual slots provides full hardware redundancy without additional external cables.
What size field wiring can be connected to the CC-GAIX11?
The detachable two-level field terminal blocks on the CC-GAIX11 accept stranded field wiring up to 12 AWG (2.5 mm²).
Reviews

CC-GAIX11

Stock & lead time on request

Call
1 of 3

Honeywell CC-GAIX11 Analog Input GI/IS Redundant IOTA

Only 7 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: CC-GAIX11

  • Country of origin:United States

  • Product Type: Redundant Analog Input IOTA

  • Payment: T/T, Western Union

  • Weight: 650g

  • Dimensions: 310 x 160 x 60 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Honeywell CC-GAIX11 is a Redundant Analog Input GI/IS IOTA (Galvanic Isolation / Intrinsically Safe Input Output Termination Assembly) designed for high-availability process control within the Honeywell Experion PKS Series C I/O architecture. It provides the physical and electrical interface required to land field sensor signals and route them securely to paired Series C Analog Input Modules, such as the CC-PAIH01, CC-PAIH02, CC-PAIX01, or CC-PAIX02.

Built for critical industrial operations, the CC-GAIX11 incorporates redundant IOM mounting positions directly on the board. This configuration allows two compatible Series C Analog Input Modules to operate in a parallel, redundant setup without requiring external switching hardware or additional cross-cabling. The assembly provides built-in signal conditioning and field power distribution, ensuring reliable data acquisition from 4-20mA and voltage transmitters across demanding processing environments.

Features

  • Redundant Architecture: Supports two plug-in Series C I/O modules on a single assembly for seamless hardware fault tolerance.
  • Galvanic Isolation / Intrinsically Safe (GI/IS) Support: Formed specifically to interface with galvanically isolated field circuits for safety-critical plant environments.
  • Compact 12-Inch Form Factor: Standardized 12-inch (304 mm) IOTA footprint maximizes cabinet density while providing full termination access.
  • Direct-Bus Powering: Receives primary 24 VDC operating power directly from the mounting carrier bus, eliminating extra power distribution wiring.
  • Integrated Signal Routing: Combines process signal conditioning and redundant network bus connection (I/O LINK) on a single board assembly.
  • Detachable Screw Terminals: Features two-level field wiring terminals to facilitate simplified installation, maintenance, and field loops testing.

Applications

  • Hazardous Area Field Interfacing: Integrates process transmitters installed in demanding process zones into the Experion C300 controller platform.
  • Redundant Analog Data Acquisition: Guarantees uninterrupted monitoring of critical process variables such as flow, pressure, level, and temperature.
  • DCS Cabinet Optimization: Reduces overall enclosure footprint by integrating field terminations, power distribution, and redundancy on one board.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model CC-GAIX11
Product Type Redundant Analog Input GI/IS IOTA
Series Experion Series C I/O
Compatible IOM Models CC-PAIH01, CC-PAIH02, CC-PAIX01, CC-PAIX02
Redundancy Yes (Dual IOM Slot)
Physical Size 12 inches (304 mm)
Input Channels 16 Channels
Field Signal Types 4-20 mA, 0 to 5 V, 1 to 5 V, 0.4 to 2 V
Field Power Supply 24 VDC via IOTA Carrier Bus
Field Wiring Terminals Detachable two-level terminal blocks
Maximum Wire Size 12 AWG / 2.5 mm2 stranded wire

Connections / Interfaces

Interface Function
IOM Plug-in Slots Dual mounting positions for redundant High-Level Analog Input Modules
Field Terminal Blocks Detachable 2-level screw terminals for field transmitter wiring
Carrier Power Interface Direct bus connections for 24 VDC system power entry
System I/O Link On-board routing to the Experion C300 controller network

Installation Guidelines

  1. Pre-Installation Inspection: Verify that the CC-GAIX11 assembly is undamaged and that the mounting carrier slots are clean and free of debris.
  2. Mounting: Securely mount the IOTA onto the Series C cabinet enclosure base or carrier rail, ensuring proper engagement with the 24 VDC power bus.
  3. Wiring Connections: Land field wiring on the two-level detachable terminal blocks using stranded wire up to 12 AWG (2.5 mm²). Ensure shield and signal commons are properly routed according to plant grounding guidelines.
  4. Module Insertion: Carefully align and plug the designated Analog Input Modules (e.g., CC-PAIH02 or CC-PAIX02) into the primary and redundant IOM positions on the IOTA until fully seated and locked.
  5. Power Verification: Confirm proper 24 VDC supply voltage at the carrier bus prior to commissioning control loops.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell CC-GAIX11 Analog Input GI/IS Redundant IOTA

What is the primary function of the Honeywell CC-GAIX11?

The CC-GAIX11 is a 12-inch redundant Input Output Termination Assembly (IOTA) in the Honeywell Experion Series C system. It connects field analog input signals to paired Series C Analog Input Modules, providing signal routing, power distribution, and fault-tolerant operation.

Which Honeywell I/O modules plug into the CC-GAIX11 IOTA?

The CC-GAIX11 supports High-Level Analog Input Modules, including models CC-PAIH01, CC-PAIH02, CC-PAIX01, and CC-PAIX02, enabling both HART and non-HART analog data collection.

Does the CC-GAIX11 require separate redundancy control cabling?

No. Redundancy is handled directly on the CC-GAIX11 board assembly. Simply installing two compatible Analog Input Modules onto the dual slots provides full hardware redundancy without additional external cables.

What size field wiring can be connected to the CC-GAIX11?

The detachable two-level field terminal blocks on the CC-GAIX11 accept stranded field wiring up to 12 AWG (2.5 mm²).

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...