Implementing 3-Switch XOR Ladder Logic with Internal Bit
Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.
The Honeywell CC-PAON01 51410070-176 is a 16-channel non-HART Analog Output Module (AOM) designed for execution within the Experion PKS Series C I/O architecture. Operating on an IOLINK managed by a C300 controller, the module receives digital control commands from the controller software and generates precise, analog 4-20mA current signals to drive field actuators, control valves, positioners, and variable speed drives.
Engineered as a core component of the Experion PKS automation platform, the Honeywell CC-PAON01 51410070-176 occupies a dedicated slot on a compatible Input Output Termination Assembly (IOTA). It utilizes an IOM block designation of AO. The module features a vertical, tilted form factor optimized for cabinet heat dissipation, toolless field replacement, and seamless integration with single or redundant IOTA configurations.
Compared to earlier analog output variants such as the CC-PAOX01, the Honeywell CC-PAON01 51410070-176 represents an updated hardware baseline designed for non-HART loop control. In redundant implementations, paired modules share the control load and provide auto-failover, ensuring continuous output generation for critical process loops.
| Parameter | Specification |
|---|---|
| Manufacturer | Honeywell |
| Model Number | CC-PAON01 |
| Part Number | 51410070-176 |
| Product Type | Series C Analog Output Module (Non-HART) |
| System Platform | Experion PKS |
| Controller Interface | C300 Controller via IOLINK |
| Channel Capacity | 16 Channels |
| Output Signal Range | 4-20 mA |
| HART Communication | Not Supported |
| IOM Block Name | AO |
| Equivalent PM I/O IOP Type | AO16 |
| Compatible Non-Redundant IOTA | CC-TAON01 |
| Compatible Redundant IOTA | CC-TAON11 |
| Module Initialization Time | 10 seconds (±25%) post module power loss |
| Cabinet Level Recovery Time | 60 seconds (±25%) post cabinet power loss |
| Interface / Assembly | Function |
|---|---|
| Backplane/IOTA Connector | Connects the module to the IOTA board for internal 24V DC power and dual IOLINK communications |
| CC-TAON01 Terminal Block | Interface for 16 non-redundant field output loops |
| CC-TAON11 Terminal Block | Dual-module interface providing redundant 16-channel field output connections |
Global Express Shipping
Returns & Warranty



The Honeywell CC-PAON01 51410070-176 is a 16-channel non-HART Analog Output Module (AOM) designed for execution within the Experion PKS Series C I/O architecture. Operating on an IOLINK managed by a C300 controller, the module receives digital control commands from the controller software and generates precise, analog 4-20mA current signals to drive field actuators, control valves, positioners, and variable speed drives.
Engineered as a core component of the Experion PKS automation platform, the Honeywell CC-PAON01 51410070-176 occupies a dedicated slot on a compatible Input Output Termination Assembly (IOTA). It utilizes an IOM block designation of AO. The module features a vertical, tilted form factor optimized for cabinet heat dissipation, toolless field replacement, and seamless integration with single or redundant IOTA configurations.
Compared to earlier analog output variants such as the CC-PAOX01, the Honeywell CC-PAON01 51410070-176 represents an updated hardware baseline designed for non-HART loop control. In redundant implementations, paired modules share the control load and provide auto-failover, ensuring continuous output generation for critical process loops.
| Parameter | Specification |
|---|---|
| Manufacturer | Honeywell |
| Model Number | CC-PAON01 |
| Part Number | 51410070-176 |
| Product Type | Series C Analog Output Module (Non-HART) |
| System Platform | Experion PKS |
| Controller Interface | C300 Controller via IOLINK |
| Channel Capacity | 16 Channels |
| Output Signal Range | 4-20 mA |
| HART Communication | Not Supported |
| IOM Block Name | AO |
| Equivalent PM I/O IOP Type | AO16 |
| Compatible Non-Redundant IOTA | CC-TAON01 |
| Compatible Redundant IOTA | CC-TAON11 |
| Module Initialization Time | 10 seconds (±25%) post module power loss |
| Cabinet Level Recovery Time | 60 seconds (±25%) post cabinet power loss |
| Interface / Assembly | Function |
|---|---|
| Backplane/IOTA Connector | Connects the module to the IOTA board for internal 24V DC power and dual IOLINK communications |
| CC-TAON01 Terminal Block | Interface for 16 non-redundant field output loops |
| CC-TAON11 Terminal Block | Dual-module interface providing redundant 16-channel field output connections |
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Color pattern |
Greyish White
|
| Country of origin |
United States
|
| Power source |
DC Power
|