Description

The Honeywell CC-TFB412 (Part Number:51308311-275 ) is a redundant Fieldbus Interface Input Output Termination Assembly (IOTA) module designed for the Experion Series C system. It provides physical termination and connection points for field-level network gateways and I/O modules when used in conjunction with the C300 Controller. The CC-TFB412 features a chassis-less mounting design, allowing electronic modules to plug directly onto the termination assembly to combine electronics and field wiring in a single area. The module is conformally coated for enhanced environmental protection.

Features

  • Support for redundant Fieldbus interface configurations
  • Chassis-less mounting structure for direct module integration
  • Conformally coated printed wiring boards for environmental protection
  • Integrated Ethernet interface connections

Applications

  • Distributed process control systems
  • Industrial automation fieldbus communication networks
  • Experion Series C and C300 Controller system deployments

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model CC-TFB412
Part Number 51308311-275
Voltage 12 VDC
Current 100 mA
Load Voltage 24 VDC
Load Current 0.196 A
Operating Temperature -40 to 185 degF (-40 to 85 degC)
Storage Temperature -40 to 185 degF (-40 to 85 degC)
Redundancy Redundant
Ethernet Connections 4 RJ-45 Connections
FF Wiring 24 VDC (external) / 350 mA total

Installation Guidelines

  • Mount the module to compatible Experion Series C termination assembly locations.
  • Ensure proper field wiring connection for 24 VDC external power and fieldbus communication links.
  • Route Ethernet lines via the dedicated RJ-45 redundant network connectors.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the Honeywell CC-TFB412 used for?
The Honeywell CC-TFB412 is a redundant Fieldbus Interface Input Output Termination Assembly (IOTA) module used in the Experion Series C system to provide termination and connection points for fieldbus networks and C300 Controllers.
Which system does the CC-TFB412 module belong to?
The module belongs to the Honeywell Experion Series C process control system and operates alongside C300 Controllers.
Does the CC-TFB412 support redundant communication connections?
Yes. The module supports redundant Fieldbus interface configurations and includes 4 RJ-45 Ethernet connections for network routing.
What power parameters are specified for the Honeywell CC-TFB412?
The module operates at 12 VDC at 100 mA, with load specifications of 24 VDC and 0.196 A, plus support for external 24 VDC FF wiring at 350 mA total.
Reviews

CC-TFB412 51308311-275

Stock & lead time on request

Call
1 of 3

Honeywell CC-TFB412 51308311-275 Experion Series C Fieldbus Interface IOTA Module

Only 3 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: CC-TFB412 51308311-275

  • Country of origin:United States

  • Product Type: Fieldbus Interface IOTA Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 130 mm x 130 mm x 85 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Honeywell CC-TFB412 (Part Number:51308311-275 ) is a redundant Fieldbus Interface Input Output Termination Assembly (IOTA) module designed for the Experion Series C system. It provides physical termination and connection points for field-level network gateways and I/O modules when used in conjunction with the C300 Controller. The CC-TFB412 features a chassis-less mounting design, allowing electronic modules to plug directly onto the termination assembly to combine electronics and field wiring in a single area. The module is conformally coated for enhanced environmental protection.

Features

  • Support for redundant Fieldbus interface configurations
  • Chassis-less mounting structure for direct module integration
  • Conformally coated printed wiring boards for environmental protection
  • Integrated Ethernet interface connections

Applications

  • Distributed process control systems
  • Industrial automation fieldbus communication networks
  • Experion Series C and C300 Controller system deployments

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model CC-TFB412
Part Number 51308311-275
Voltage 12 VDC
Current 100 mA
Load Voltage 24 VDC
Load Current 0.196 A
Operating Temperature -40 to 185 degF (-40 to 85 degC)
Storage Temperature -40 to 185 degF (-40 to 85 degC)
Redundancy Redundant
Ethernet Connections 4 RJ-45 Connections
FF Wiring 24 VDC (external) / 350 mA total

Installation Guidelines

  • Mount the module to compatible Experion Series C termination assembly locations.
  • Ensure proper field wiring connection for 24 VDC external power and fieldbus communication links.
  • Route Ethernet lines via the dedicated RJ-45 redundant network connectors.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell CC-TFB412 51308311-275 Experion Series C Fieldbus Interface IOTA Module

What is the Honeywell CC-TFB412 used for?

The Honeywell CC-TFB412 is a redundant Fieldbus Interface Input Output Termination Assembly (IOTA) module used in the Experion Series C system to provide termination and connection points for fieldbus networks and C300 Controllers.

Which system does the CC-TFB412 module belong to?

The module belongs to the Honeywell Experion Series C process control system and operates alongside C300 Controllers.

Does the CC-TFB412 support redundant communication connections?

Yes. The module supports redundant Fieldbus interface configurations and includes 4 RJ-45 Ethernet connections for network routing.

What power parameters are specified for the Honeywell CC-TFB412?

The module operates at 12 VDC at 100 mA, with load specifications of 24 VDC and 0.196 A, plus support for external 24 VDC FF wiring at 350 mA total.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...