The Honeywell FS-IOBUS-CPIOX6 is a vertical IO bus cable assembly consisting of a 34-wire flat cable designed for Honeywell Safety Manager extension cabinets. It establishes the IO bus connection between a Controller chassis (CPCHAS-0001 or CPCHAS-0002) and I/O chassis (IOCHAS-0001S, IOCHAS-0001R, IOCHAS-0002S, or IOCHAS-0002R) in positions 1, 2, 3, 4, 5, and 6.

All scan, test, and update actions between the QPP module and IO modules are routed through this cable assembly. It supports both redundant and non-redundant Controller and IO configurations.

Features

  • 34-Wire Flat Cable Design: Constructed specifically as a 34-wire flat cable assembly for vertical IO bus interconnections.
  • Multi-Position Connectivity: Connects the Controller chassis to I/O chassis located across positions 1 through 6.
  • Flexible Configuration Support: Designed to handle both redundant and non-redundant system architectures.
  • Integrated Signal Routing: Routes all scan, test, and update communication traffic between the QPP module and IO modules.
  • Certified Compliance: Approved under UL, CSA, and VDE standards.

Applications

  • Safety Manager Extension Cabinets: Interconnecting Controller racks and I/O sub-racks inside vertical extension cabinet configurations.
  • Multi-Rack I/O Expansion: Providing IO bus communication across up to 6 stacked I/O chassis positions.
  • Redundant & Non-Redundant Systems: Serving as the IO bus communication medium for both single and redundant Controller and IO setups.

Technical Specifications

Parameter Specification
Model / Type Number FS-IOBUS-CPIOX6
Cable Type 34-wire flat cable
Compatible Controller Chassis CPCHAS-0001, CPCHAS-0002
Compatible I/O Chassis IOCHAS-0001S, IOCHAS-0001R, IOCHAS-0002S, IOCHAS-0002R
Supported Chassis Positions Controller chassis to I/O chassis in positions 1, 2, 3, 4, 5, and 6
Configuration Compatibility Redundant and non-redundant (Controller and/or IO)
Approvals UL, CSA, VDE

FAQ

What is the Honeywell FS-IOBUS-CPIOX6 used for?

The FS-IOBUS-CPIOX6 is a vertical 34-wire IO bus cable assembly for Honeywell Safety Manager extension cabinets. It carries scan, test, and update communication between the QPP control processor and connected I/O modules.

How many I/O chassis positions does FS-IOBUS-CPIOX6 cover?

The FS-IOBUS-CPIOX6 is intended for I/O chassis positions 1 through 6. Honeywell provides separate CPIOX1 through CPIOX9 assemblies, so the cable variant should match the required cabinet chassis positions.

Which chassis are compatible with FS-IOBUS-CPIOX6?

The documented IOBUS-CPIOXx family connects CPCHAS-0001 or CPCHAS-0002 controller chassis with IOCHAS-0001S, IOCHAS-0001R, IOCHAS-0002S, or IOCHAS-0002R I/O chassis inside a Safety Manager extension cabinet.

Can FS-IOBUS-CPIOX6 be used with redundant I/O?

Yes. Honeywell documents the IOBUS-CPIOXx assemblies for both redundant and non-redundant controller or I/O configurations. The actual cabling topology should follow the engineered Safety Manager cabinet configuration.

What should be checked before replacing FS-IOBUS-CPIOX6?

Verify the exact part number, supported controller and I/O chassis types, cabinet topology, and required chassis positions. Record the existing routing and connections before removal, then verify communication and diagnostics after installation.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...