Designing Power and Communication Redundancy
Design control-system redundancy by mapping shared dependencies, separating power and network paths, defining failover behavior, exposing degraded operation, and proof-testing every tolerated fault.
Manufacturer: Honeywell
Product No.: FS-PSU-240516 CC V1.1
Country of origin:United States
Product Type: PLC Power Supply Modules
Payment: T/T, Western Union
Weight: 3000g
Dimensions: 21.2 cm x 3.52 cm x 17.6 cm
Shipping port: Xiamen
Warranty: 12 months
Designed for seamless integration into high-integrity safety architectures, this Honeywell FS-PSU-240516 CC V1.1 power supply module converts and regulates input power to sustain demanding system logic loads. Purpose-built for the Honeywell Safety Manager and Fail Safe Controller (FSC) systems, it provides stabilized 24 Vdc and 5 Vdc outputs with a combined capacity of 16 A. The CC designation denotes conformal coating, providing superior resistance against moisture, dust, and corrosive industrial atmospheric agents.
| Manufacturer | Honeywell |
| Model / SKU | FS-PSU-240516 CC V1.1 |
| Nominal Output Voltage | 24 Vdc and 5 Vdc |
| Maximum Rated Current | 16 A |
| Input Supply Range | 24 Vdc (-15% to +30%) |
| Inrush Current | Less than 5 A at 24 Vin |
| Hold-up Time | Less than 1 ms |
| Conformal Coating | Yes (CC version) |
| Operating Temperature | -5 degC to +70 degC (+23 degF to +158 degF) |
| Storage Temperature | -40 degC to +85 degC (-40 degF to +185 degF) |
| Relative Humidity | 10% to 95% (non-condensing) |
| Dimensions (L x W x H) | 21.2 cm x 3.52 cm x 17.6 cm |
| Net Weight | 0.85 kg |
| Shipping Weight (Calculated) | 3.00 kg |
| System Certifications | CE, TUV, UL, CSA, FM |
This model replaces standard non-conformal coated variations (FS-PSU-240516). Systems requiring backward compatibility with firmware Safety Manager R120 or earlier must verify card-carrier physical clearances and revision profiles, as version 1.1 features an optimized heat-sink footprint.
When housing multiple FS-PSU modules within a tightly enclosed safety panel, thermal stratification can lead to accelerated component aging. Maintain a minimum vertical spacing clearance of 50 mm above and below the card chassis to permit convection airflow and ensure the ambient local temperature remains below +70 degC.
Always verify feed circuit supply integrity. The input tolerance allows 24 Vdc input variations from -15% to +30%, but keeping the incoming voltage at a stable nominal 24 Vdc optimizes internal regulator efficiency and minimizes excessive heat dissipation within the module's enclosure.
Isolate and lockout all active primary power feeds prior to physical module replacement. Working on energized components in safety-instrumented systems poses severe risks of accidental ESD system trip, electrical shock, and hardware degradation.