Honeywell

Honeywell MC-TAOY22 Analog Output with Compression Terminals

SKU MC-TAOY22

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: MC-TAOY22

  • Country of origin:United States

  • Product Type: Analog Output Modules

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Honeywell MC-TAOY22 is an Analog Output module equipped with compression terminals, designed for high-reliability signal transmission in industrial process control environments. This module acts as a bridge between digital control systems and field instrumentation, converting control logic into precise analog signals (such as 4-20mA). By utilizing compression terminals, the MC-TAOY22 ensures a secure and vibration-resistant connection for field wiring, which is critical for maintaining signal integrity in demanding industrial setups.

Features

  • Analog Output signal conversion for precise process regulation
  • Equipped with compression terminals for secure, low-maintenance field wiring
  • Designed for standard Honeywell control rack compatibility
  • Robust construction for long-term operational stability

Applications

  • Distributed Control Systems (DCS) for process automation
  • Control of variable frequency drives (VFD) and industrial actuators
  • Regulation of proportional control valves
  • Industrial instrumentation and signal transmission

Technical Specifications

Feature Specification
Manufacturer Honeywell
Product Number MC-TAOY22
Product Type Analog Output with compression terminals
Estimated Lead Time 2 - 3 weeks
Shipping Weight 1.5 Kg

Installation Guidelines

  • Ensure the module is seated firmly into the backplane to prevent intermittent connectivity.
  • Use appropriate wire preparation when inserting conductors into the compression terminals; ensure the wire is stripped to the manufacturer's specified length.
  • Tighten compression screws to the recommended torque to ensure a solid mechanical and electrical connection.
  • Route analog signal cables separately from high-voltage AC lines to mitigate electromagnetic interference (EMI).
  • Perform a loop calibration check after installation to confirm signal accuracy across the full output range.

FAQ

What is the benefit of the compression terminals on the MC-TAOY22?

The compression terminals provide a secure, vibration-resistant connection for field wiring, ensuring long-term signal integrity in industrial environments.

What is the primary function of this module?

This module converts digital control signals from a controller into precise analog outputs used to regulate field devices like actuators and valves.

What is the estimated lead time for this part?

The estimated lead time is currently 2 to 3 weeks.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
United States

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.