Description

The Honeywell SPS6061-LF FC-PSUNI2424 is a switched-mode AC to DC power supply module designed for connection to industrial installations for use in process and safety controllers. The SPS6061-LF FC-PSUNI2424 delivers a 600W nominal power output with high efficiency, accepting a wide AC input range between 100VAC and 240VAC and converting it to a regulated 24V DC output. Engineered with dual independent over-voltage protection supporting IEC 61508 architectural constraints, the device provides SIL3-certified over-voltage protection that guarantees output levels remain below 31VDC. The power supply features an integrated power switch and an isolated solid-state Opto-FET alarm contact for real-time module status monitoring.

Features

  • Dual built-in over-voltage protection supporting SIL3 applications according to IEC 61508.
  • Integrated ON/OFF power switch combined with isolated AC and DC power connectors enabling on-line replacement in a live system.
  • Supports parallel operation of up to eight units to deliver higher output currents with load sharing within 10% difference at full load.
  • Wide operating temperature capability from -40 degC to 70 degC with controlled fan speed reduction.
  • DC under-voltage protection (<23.5V) and AC under-voltage protection (<80V) alarms.
  • Greater than 50ms hold-up time and 50A/200ms peak output current capability for clearing downstream fuses.
  • Continuous protection against short-circuiting and overload via an electronic current limiter.
  • Inrush current limited to under 60A, supporting 10A type C circuit breakers.

Applications

  • Process and safety controller power distribution systems.
  • Industrial SIL3 safety instrumented systems requiring SELV 24VDC power supply architecture.
  • Field instrumentation loops utilizing HART communication protocol.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Type Number FC-PSUNI2424
Output Power 600W
Output Voltage 25.7V no load; 25.1V with 24A static load; 24.5-26.5V with 24A dynamic load
Output Current 0-24A continuously; 50A for 200ms typical for clearing fuses
Input Voltage 100-120 / 220-240VAC nominal (Operational between 85 - 265VAC)
Input Power 115VAC: 712W; 230VAC: 691W typical (85VAC: 750W; 220VAC: 720W maximum)
Power Efficiency 100VAC: 80% @ 6A and 84.5% @ 12-24A; 230VAC: 82% @ 6A and 87% @ 12-24A
Power Factor 100VAC: >0.99 @ 6-24A; 230VAC: >0.88 @ 6A and 0.98 @ 24A
Input Frequency Range 45-66Hz
Input Current 115VAC: 6.2A; 230VAC: 3.1A (at rated DC output load)
Inrush Current <60A
Internal Fusing 10A fuse for each AC leg line
External Protection Fuse: 10A class CC or MCB: 10-13A type C (EN60898-1)
Hold-up Time 50ms
Ripple 20-40mV typical (HART compliant)
Noise <100mV LL and <700mV LE
Load Sharing <10% difference at full load
Electronic Current Limiter 34A typical (27A-42A) after 200ms
Derating Output Current Single operation: 24A with -0.6A/degC above 60degC up to 2000m altitude; Parallel operation: 24A with -0.6A/degC above 50degC up to 2000m altitude
Alarm Output Type Solid-state output (Opto-FET) isolated up to 500VAC
Alarm Activation Activated when power supply status is okay (FAN speed okay and output voltage >23.5V)
Alarm Nominal Voltage 31V maximum (33V TVS protected inside)
Alarm Nominal Current 40mA maximum non inductive
Alarm Voltage Drop <0.2V at 7mA
Alarm Short Circuit Protection Yes (Trips within 1 second at 0.5A - self restoring)
FAN Speed 0% below -10degC, 50% above -10degC, 100% above 80-85degC heatsink temperature
Isolation Input to Output 3750VAC/1min (8mm creepage)
Isolation Input to Case 2210VAC/1min; Transient limited by 3000V spark gap and 300VAC varistor in series; 100% tested at 2300VDC
Isolation Output to Case 1500VDC/1min; Transient limited by 320VAC varistor; <50M Ohm at 250VDC
Storage Temperature -40degC to 85degC (Keep below 40degC for long term storage)
Operating Temperature -40degC to 70degC
Maximum Temperature Change 3degC/minute
Humidity 5% to 95% RH non-condensing (Derating RH above 40degC)
Pollution Degree PD2 maximum (IEC60664-1)
Altitude 0-2000m above sea level
Dimensions (W x H x D) 370 x 159 x 67.3 mm
Weight 2.9 kg

Connections/Interfaces

Connector Pin Function
AC Mating Connector PX0597, BULGIN C15 IEC (Cable: 80042 EcoFlex, 3x 16AWG)
DC Mating Connector 1967456 PC 16/2-stf-10,16, Phoenix Contact (Cable: HV8-55-0 AND HV8-55-2, PowerFlex 1000, 8AWG)
Alarm Mating Connector 1827703 MC 1,5/2-STF-3,81 (20-24AWG Alarm wire)

Installation Guidelines

  • Mounting Orientation: Mount the unit vertically or horizontally. Vertical mounting is preferred for optimal convection cooling, with the power and fan input facing downwards.
  • Blade Spacing: Maintain an absolute minimum spacing of 12.5 mm (0.5 in) between two blade-mounted units.
  • Power Switch Operation: Turn off the power switch before disconnecting the unit. After switching the unit OFF, wait at least 30 seconds before switching it ON again to avoid permanent damage.
  • External Circuit Protection: Each power supply AC input requires a double pole external 10A circuit breaker (type C) or 10A class CC fuse in series for electrical safety.
  • Altitude Derating: Ensure output load derating starts 10degC earlier when DC outputs are configured in parallel.

Compliance and Certifications

  • CE
  • cUL (60950)
  • SELV certified according to EN60950
  • SIL3 certified for over-voltage protection (IEC 61508)
  • EMC Standards: EN61131-2, EN50130-4, EN61000-6-7
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What primary output specification does the power supply unit deliver under full dynamic load?
The module delivers a regulated 24.5V to 26.5V DC output with up to 24A dynamic load current.
How long must engineers wait before turning the power switch back on after switching off?
Wait at least 30 seconds before switching the unit back ON to prevent permanent hardware damage.
How many power supply modules can operate in parallel to support higher output currents?
Up to eight power supply units can be connected in parallel with load sharing active within 10%.
Reviews

SPS6061-LF FC-PSUNI2424

Stock &amp; lead time on request

Call
1 of 3

Honeywell SPS6061-LF FC-PSUNI2424 Safety Manager Power Supply Module

Only 4 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: SPS6061-LF FC-PSUNI2424

  • Country of origin:United States

  • Product Type: Power Supply Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 2900g

  • Dimensions: 370 x 159 x 67.3 mm (W x H x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Honeywell SPS6061-LF FC-PSUNI2424 is a switched-mode AC to DC power supply module designed for connection to industrial installations for use in process and safety controllers. The SPS6061-LF FC-PSUNI2424 delivers a 600W nominal power output with high efficiency, accepting a wide AC input range between 100VAC and 240VAC and converting it to a regulated 24V DC output. Engineered with dual independent over-voltage protection supporting IEC 61508 architectural constraints, the device provides SIL3-certified over-voltage protection that guarantees output levels remain below 31VDC. The power supply features an integrated power switch and an isolated solid-state Opto-FET alarm contact for real-time module status monitoring.

Features

  • Dual built-in over-voltage protection supporting SIL3 applications according to IEC 61508.
  • Integrated ON/OFF power switch combined with isolated AC and DC power connectors enabling on-line replacement in a live system.
  • Supports parallel operation of up to eight units to deliver higher output currents with load sharing within 10% difference at full load.
  • Wide operating temperature capability from -40 degC to 70 degC with controlled fan speed reduction.
  • DC under-voltage protection (<23.5V) and AC under-voltage protection (<80V) alarms.
  • Greater than 50ms hold-up time and 50A/200ms peak output current capability for clearing downstream fuses.
  • Continuous protection against short-circuiting and overload via an electronic current limiter.
  • Inrush current limited to under 60A, supporting 10A type C circuit breakers.

Applications

  • Process and safety controller power distribution systems.
  • Industrial SIL3 safety instrumented systems requiring SELV 24VDC power supply architecture.
  • Field instrumentation loops utilizing HART communication protocol.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Type Number FC-PSUNI2424
Output Power 600W
Output Voltage 25.7V no load; 25.1V with 24A static load; 24.5-26.5V with 24A dynamic load
Output Current 0-24A continuously; 50A for 200ms typical for clearing fuses
Input Voltage 100-120 / 220-240VAC nominal (Operational between 85 - 265VAC)
Input Power 115VAC: 712W; 230VAC: 691W typical (85VAC: 750W; 220VAC: 720W maximum)
Power Efficiency 100VAC: 80% @ 6A and 84.5% @ 12-24A; 230VAC: 82% @ 6A and 87% @ 12-24A
Power Factor 100VAC: >0.99 @ 6-24A; 230VAC: >0.88 @ 6A and 0.98 @ 24A
Input Frequency Range 45-66Hz
Input Current 115VAC: 6.2A; 230VAC: 3.1A (at rated DC output load)
Inrush Current <60A
Internal Fusing 10A fuse for each AC leg line
External Protection Fuse: 10A class CC or MCB: 10-13A type C (EN60898-1)
Hold-up Time 50ms
Ripple 20-40mV typical (HART compliant)
Noise <100mV LL and <700mV LE
Load Sharing <10% difference at full load
Electronic Current Limiter 34A typical (27A-42A) after 200ms
Derating Output Current Single operation: 24A with -0.6A/degC above 60degC up to 2000m altitude; Parallel operation: 24A with -0.6A/degC above 50degC up to 2000m altitude
Alarm Output Type Solid-state output (Opto-FET) isolated up to 500VAC
Alarm Activation Activated when power supply status is okay (FAN speed okay and output voltage >23.5V)
Alarm Nominal Voltage 31V maximum (33V TVS protected inside)
Alarm Nominal Current 40mA maximum non inductive
Alarm Voltage Drop <0.2V at 7mA
Alarm Short Circuit Protection Yes (Trips within 1 second at 0.5A - self restoring)
FAN Speed 0% below -10degC, 50% above -10degC, 100% above 80-85degC heatsink temperature
Isolation Input to Output 3750VAC/1min (8mm creepage)
Isolation Input to Case 2210VAC/1min; Transient limited by 3000V spark gap and 300VAC varistor in series; 100% tested at 2300VDC
Isolation Output to Case 1500VDC/1min; Transient limited by 320VAC varistor; <50M Ohm at 250VDC
Storage Temperature -40degC to 85degC (Keep below 40degC for long term storage)
Operating Temperature -40degC to 70degC
Maximum Temperature Change 3degC/minute
Humidity 5% to 95% RH non-condensing (Derating RH above 40degC)
Pollution Degree PD2 maximum (IEC60664-1)
Altitude 0-2000m above sea level
Dimensions (W x H x D) 370 x 159 x 67.3 mm
Weight 2.9 kg

Connections/Interfaces

Connector Pin Function
AC Mating Connector PX0597, BULGIN C15 IEC (Cable: 80042 EcoFlex, 3x 16AWG)
DC Mating Connector 1967456 PC 16/2-stf-10,16, Phoenix Contact (Cable: HV8-55-0 AND HV8-55-2, PowerFlex 1000, 8AWG)
Alarm Mating Connector 1827703 MC 1,5/2-STF-3,81 (20-24AWG Alarm wire)

Installation Guidelines

  • Mounting Orientation: Mount the unit vertically or horizontally. Vertical mounting is preferred for optimal convection cooling, with the power and fan input facing downwards.
  • Blade Spacing: Maintain an absolute minimum spacing of 12.5 mm (0.5 in) between two blade-mounted units.
  • Power Switch Operation: Turn off the power switch before disconnecting the unit. After switching the unit OFF, wait at least 30 seconds before switching it ON again to avoid permanent damage.
  • External Circuit Protection: Each power supply AC input requires a double pole external 10A circuit breaker (type C) or 10A class CC fuse in series for electrical safety.
  • Altitude Derating: Ensure output load derating starts 10degC earlier when DC outputs are configured in parallel.

Compliance and Certifications

  • CE
  • cUL (60950)
  • SELV certified according to EN60950
  • SIL3 certified for over-voltage protection (IEC 61508)
  • EMC Standards: EN61131-2, EN50130-4, EN61000-6-7
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell SPS6061-LF FC-PSUNI2424 Safety Manager Power Supply Module

What primary output specification does the power supply unit deliver under full dynamic load?

The module delivers a regulated 24.5V to 26.5V DC output with up to 24A dynamic load current.

How long must engineers wait before turning the power switch back on after switching off?

Wait at least 30 seconds before switching the unit back ON to prevent permanent hardware damage.

How many power supply modules can operate in parallel to support higher output currents?

Up to eight power supply units can be connected in parallel with load sharing active within 10%.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
United States
Power source
AC-powered

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...