Honeywell

Honeywell STT17H-00-0-00R-00E-D00-00 Smart Temperature Transmitter

SKU STT17H-00-0-00R-00E-D00-00

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: STT17H-00-0-00R-00E-D00-00

  • Country of origin:United States

  • Product Type: Temperature Transmitters

  • Payment: T/T, Western Union

  • Weight: 1300g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Process automation systems rely on the Honeywell STT17H-00-0-00R-00E-D00-00 headmount temperature transmitter to convert low-level sensor inputs into stable control-level signals. This DIN Form B compatible unit functions as a high-performance signal converter, accepting RTD, thermocouple, resistance, and millivolt sensor configurations. Utilizing dual-sensor input capabilities, it supports differential or average temperature monitoring while ensuring complete galvanic isolation to protect downstream PLC and DCS components from ground loop noise and common-mode voltage transients.

Key Features

  • HART Protocol Integration: Supports HART communications overlayed on a standard 4-20 mA analog output loop, enabling remote calibration and diagnostics.
  • Universal Input Versatility: Direct interface compatibility with standard RTD, thermocouple (T/C), linear resistance (Ohm), and millivolt (mV) inputs.
  • Dual-Sensor Calculations: Configurable for single or dual sensor inputs to execute difference or average calculations in critical process points.
  • HART Multidrop Capabilities: Enables multi-device digital network layouts over a single twisted-pair wire run.
  • NAMUR NE43 Compliance: Provides deterministic sensor error response profiles to ensure field safety and predictive diagnostic coverage.
  • Galvanic Isolation: Heavy-duty electrical isolation between input stage and loop circuit prevents noise propagation.

Industrial Applications

  • Petrochemical and chemical processing temperature monitoring loops.
  • Power generation steam temperatures and bearing monitoring.
  • Refinery column differential temperature thermal profiling.
  • Heavy industrial OEM machinery and heat treatment systems.

Technical Specifications

Manufacturer Honeywell
Model Number STT17H-00-0-00R-00E-D00-00
Output Signal 4-20 mA analog with HART digital communication
Sensor Input Options RTD, Thermocouple, Resistance (Ohm), millivolt (mV)
Input Configuration Single or Dual (difference or average calculation)
Mechanical Mounting DIN Form B headmount configuration
Error Fault Signaling NAMUR NE43 user-configurable limits
Isolation Protection Galvanically isolated input/output circuit
Configuration Methods STT17C PC Configuration Tool or compatible HART Handheld Terminal
Shipping Weight 1.3 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The STT17H is the HART-enabled variant in the STT17 family, distinguishing itself from the basic STT171 (which offers simple 4-20 mA output with PC-only configuration) and the STT173 (which provides Foundation Fieldbus protocol options). When replacing older legacy Honeywell transmitters, ensure that your existing DCS integration blocks or handheld field communicators are loaded with the correct Device Description (DD) file for the STT17H family to allow parameter mapping.

Application Pitfalls & Engineering Notes

When configuring a dual-sensor application (e.g., differential or redundant tracking), utilize non-grounded thermocouple configurations. If grounded thermocouples are installed in a dual-sensor layout, ground loops can form across the shared sensor terminal block, degrading measurement linearity. In environments with heavy high-frequency noise from nearby variable speed drives, ensure that sensor input leads remain as short as possible within the Form B junction head.

Commissioning & Wiring Tips

When connecting the PC-based STT17C configuration tool, a loop resistance of at least 250 Ohms is strictly required between the transmitter and the interface modem. Attempting to program the device without this inline resistance will result in intermittent or failed HART communication. Ensure all field wiring uses twisted-pair, shielded cables grounded exclusively at the control panel end to avoid ground-potential differences.

Installation Guidelines

CRITICAL SAFETY WARNING

Isolate and completely de-energize the instrument loop power supply prior to opening the junction box cover or disconnecting any signal terminals. Working on live instrument loops in hazardous processing areas can trigger explosive atmospheres or damage delicate control inputs.

1

Mount the STT17H unit securely inside the DIN Form B head closure using the provided screw brackets, taking care not to pinch internal wires.

2

Connect the physical sensor inputs to the corresponding designated terminal screws, ensuring compliance with the chosen RTD or thermocouple wiring topology.

3

Connect the positive (+) and negative (-) 4-20 mA loop wires, verifying polarity match with the analog input channel of your controller.

4

Fasten all housing screws to ensure internal moisture protection before re-applying main loop voltage.

FAQ

Can the STT17H transmitter accept dual sensor inputs of different types simultaneously?

No. When configuring dual-sensor mode for differential or average tracking, both sensors must be identical in type and calibrated range (e.g., two identical RTDs or two identical thermocouples).

What is the purpose of the 250 Ohm resistor required during configuration?

The 250 Ohm resistor is necessary to provide the proper loop impedance for the HART digital signal to modulate on the analog current loop, enabling the PC modem or field communicator to successfully establish communication.

How does the STT17H handle sensor break or burnout failures?

The transmitter features configurable NAMUR NE43 sensor error responses. If a thermocouple or RTD element burns out, the unit drives its 4-20 mA analog output to a pre-defined upscale or downscale limit to alert the PLC/DCS system immediately.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.