Honeywell

Honeywell TC-IXR061 Experion PKS Analog Input Module

SKU TC-IXR061

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: TC-IXR061

  • Country of origin:United States

  • Product Type: Analog Input Module

  • Payment: T/T, Western Union

  • Weight: 1300g

  • Shipping port: Xiamen

  • Warranty: 12 months

Overview

The TC-IXR061 (TCIXR061) is a high-precision, galvanically isolated analog input module designed for the Honeywell Experion PKS (Process Knowledge System) platform. In critical process industries such as hydrocarbon processing, large-scale chemical synthesis, and pharmaceutical manufacturing, signal integrity is non-negotiable. This module provides six channels of isolated measurement, shielding the control system from ground loops and high-voltage transients commonly found in heavy industrial environments. By providing a rapid module update rate of 50 ms and integrated open-wire detection, the TC-IXR061 ensures that operators receive immediate, accurate data for closed-loop control. This proactive diagnostic capability is vital for identifying field instrument failures before they lead to emergency shutdowns, thereby maximizing plant availability and safety.

Technical Configuration

The TC-IXR061 is engineered to maintain high-fidelity signal conversion under challenging electromagnetic conditions. Its architecture emphasizes both speed and environmental resilience.

  • Galvanic Isolation: Each of the 6 channels is individually isolated, preventing common-mode noise and ground-current interference from migrating across the I/O backplane.

  • Rapid Processing: The module features a comprehensive update rate of 50 ms for all channels, making it suitable for fast-acting control loops and sensitive monitoring applications.

  • Robust RFI Immunity: Designed to withstand high-frequency interference, the module maintains an error rate of less than 2.0 percent even in the presence of 10 V/m radio frequency fields.

  • Diagnostic Reporting: Built-in open-wire detection triggers an "Out of Range" status in less than 5 seconds, allowing for rapid fault localization in the field wiring.

Technical Specifications

Feature Specification
Model TC-IXR061
Brand Honeywell
Origin USA
I/O Type Galvanically Isolated Analog Input
Number of Points 6 Channels
Update Rate 50 ms (All channels)
Channel Bandwidth DC to 15 Hz (-3 dB)
Power Dissipation 4.3 W Maximum
Terminal Block TC-TBNH (20-position)
Open Wire Detection Reported in less than 5 seconds
Shipping Weight 1.3 kg

FAQs

How does the TC-IXR061 handle field wiring breaks?

The module includes integrated open-wire detection. If a connection is lost, the system reports an "Out of Range" value within 5 seconds. This allows the Experion PKS control strategy to transition to a predefined safe state or shed the loop to manual.

What is the benefit of the galvanic isolation on this specific module?

Standard analog inputs often share a common ground, which can introduce noise if field instruments are grounded at different potentials. The galvanic isolation in the TC-IXR061 ensures each channel is electrically independent, significantly improving accuracy in "electrically noisy" plants.

Is this module compatible with standard Experion PKS chassis?

Yes, it is designed for standard Honeywell I/O racks and utilizes the TC-TBNH 20-position terminal block for field terminations.

Engineering & Installation Guide

  • Shielding and Grounding: For optimal performance in environments with high RFI (Radio Frequency Interference), use high-quality twisted-pair shielded cable. Ensure the shield is terminated at the designated ground point on the Honeywell chassis and remains floating at the field instrument side to prevent the very ground loops the module is designed to isolate.

  • Thermal Management: The TC-IXR061 dissipates up to 4.3 W. In high-density I/O cabinets, ensure that the rack is ventilated properly. Maintain at least 2 inches of clearance at the top and bottom of the chassis to allow natural convection, preventing heat-related drift in the analog-to-digital conversion circuitry.

  • Wiring Precision: When utilizing the TC-TBNH terminal block, ensure all connections are torqued according to Honeywell standard specifications. Loose connections on high-impedance analog inputs can lead to intermittent "Out of Range" alarms and erratic signal behavior.

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
AC-powered

Technical knowledge

Engineering Logix Produced and Consumed Tags

A field-ready guide to Logix produced and consumed tags, covering data contracts, RPI selection, connection status, stale-data handling, commissioning and controller-to-controller troubleshooting.

Commissioning AS-Interface Networks Without Guesswork

A practical AS-Interface commissioning method covering topology, power and voltage-drop checks, addressing, PLC mapping, fault tests and maintenance records for reliable actuator-sensor networks.

Selecting Line Reactors and Output Filters for VFDs

Learn how line reactors, harmonic filters, output reactors, dV/dt filters, and sine filters address different VFD power-quality and motor-cable problems—and how to select them safely.

Light-On and Dark-On Photoelectric Sensor Logic

Learn how light-on and dark-on photoelectric sensor modes interact with through-beam, retroreflective, and diffuse sensing, PNP/NPN wiring, PLC logic, commissioning, and fault detection.

Designing H-Bridge Motor Drives Without Shoot-Through

A practical guide to H-bridge motor drives covering switching states, dead time, inductive current paths, PWM choices, protection, PCB layout, PLC interfacing, and staged commissioning tests.

Designing Mitsubishi FX PLC Sequences with STL and RET

Learn how Mitsubishi FX PLC STL and RET instructions structure conveyor and pneumatic sequences, with practical state design, transition logic, timeouts, diagnostics, and safe restart boundaries.