1 of 1

Honeywell TC-IXR061 Experion PKS Analog Input Module

Honeywell TC-IXR061 Experion PKS Analog Input Module

Only 1000 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: TC-IXR061

  • Country of origin: United States

  • Product Type: Analog Input Module

  • Payment:T/T, Western Union

  • Weight: 1300g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Overview

The TC-IXR061 (TCIXR061) is a high-precision, galvanically isolated analog input module designed for the Honeywell Experion PKS (Process Knowledge System) platform. In critical process industries such as hydrocarbon processing, large-scale chemical synthesis, and pharmaceutical manufacturing, signal integrity is non-negotiable. This module provides six channels of isolated measurement, shielding the control system from ground loops and high-voltage transients commonly found in heavy industrial environments. By providing a rapid module update rate of 50 ms and integrated open-wire detection, the TC-IXR061 ensures that operators receive immediate, accurate data for closed-loop control. This proactive diagnostic capability is vital for identifying field instrument failures before they lead to emergency shutdowns, thereby maximizing plant availability and safety.

Technical Configuration

The TC-IXR061 is engineered to maintain high-fidelity signal conversion under challenging electromagnetic conditions. Its architecture emphasizes both speed and environmental resilience.

  • Galvanic Isolation: Each of the 6 channels is individually isolated, preventing common-mode noise and ground-current interference from migrating across the I/O backplane.

  • Rapid Processing: The module features a comprehensive update rate of 50 ms for all channels, making it suitable for fast-acting control loops and sensitive monitoring applications.

  • Robust RFI Immunity: Designed to withstand high-frequency interference, the module maintains an error rate of less than 2.0 percent even in the presence of 10 V/m radio frequency fields.

  • Diagnostic Reporting: Built-in open-wire detection triggers an "Out of Range" status in less than 5 seconds, allowing for rapid fault localization in the field wiring.

Technical Specifications

Feature Specification
Model TC-IXR061
Brand Honeywell
Origin USA
I/O Type Galvanically Isolated Analog Input
Number of Points 6 Channels
Update Rate 50 ms (All channels)
Channel Bandwidth DC to 15 Hz (-3 dB)
Power Dissipation 4.3 W Maximum
Terminal Block TC-TBNH (20-position)
Open Wire Detection Reported in less than 5 seconds
Shipping Weight 1.3 kg

FAQs

How does the TC-IXR061 handle field wiring breaks?

The module includes integrated open-wire detection. If a connection is lost, the system reports an "Out of Range" value within 5 seconds. This allows the Experion PKS control strategy to transition to a predefined safe state or shed the loop to manual.

What is the benefit of the galvanic isolation on this specific module?

Standard analog inputs often share a common ground, which can introduce noise if field instruments are grounded at different potentials. The galvanic isolation in the TC-IXR061 ensures each channel is electrically independent, significantly improving accuracy in "electrically noisy" plants.

Is this module compatible with standard Experion PKS chassis?

Yes, it is designed for standard Honeywell I/O racks and utilizes the TC-TBNH 20-position terminal block for field terminations.

Engineering & Installation Guide

  • Shielding and Grounding: For optimal performance in environments with high RFI (Radio Frequency Interference), use high-quality twisted-pair shielded cable. Ensure the shield is terminated at the designated ground point on the Honeywell chassis and remains floating at the field instrument side to prevent the very ground loops the module is designed to isolate.

  • Thermal Management: The TC-IXR061 dissipates up to 4.3 W. In high-density I/O cabinets, ensure that the rack is ventilated properly. Maintain at least 2 inches of clearance at the top and bottom of the chassis to allow natural convection, preventing heat-related drift in the analog-to-digital conversion circuitry.

  • Wiring Precision: When utilizing the TC-TBNH terminal block, ensure all connections are torqued according to Honeywell standard specifications. Loose connections on high-impedance analog inputs can lead to intermittent "Out of Range" alarms and erratic signal behavior.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
AC-powered

Recently Viewed Products

Technical knowledge

Fundamentals of Grounding and Safety in Industrial Electrical Systems

Grounding is often invisible in industrial systems, yet it defines safety, stability, and system survival under fault conditions.

MQTT vs OPC UA: Industrial Automation Communication Protocol Comparison from an OEM Perspective

MQTT and OPC UA continue to define how industrial systems move data between machines, controllers, and cloud platforms. While one focuses on lightweight messaging for distributed environments, the...

Analog vs Fieldbus Communication Systems in Industrial Automation Explained

This article explains analog signal systems and fieldbus communication in industrial automation, comparing 4–20 mA loops with digital protocols such as Foundation Fieldbus and HART.

Industry and Education Collaboration Builds Future Automation Workforce

Industrial and education collaboration is shaping the future automation workforce by integrating robotics training, CNC systems, and hands-on technical education. These programs help students gain...

How to Program BRX PLC Using Digital I/O and Ladder Logic Basics

Learn BRX PLC programming with digital I/O, Ethernet setup, firmware update, and ladder logic basics for industrial automation applications.

How to Read PLC Ladder Logic for Troubleshooting (Part 2)

Ladder logic is a core PLC programming method used in industrial automation. Understanding how to read and troubleshoot it requires knowledge of logic flow, subroutines, and system-level control...