Honeywell TK-PRR021 51309288-475 Experion Series A Redundancy Module

Honeywell TK-PRR021 51309288-475 Experion Series A Redundancy Module

Only 4 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: TK-PRR021 51309288-475

  • Country of origin:United States

  • Product Type: Redundancy Control Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 145 mm x 137 mm x 50 mm (D x H x W)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Honeywell TK-PRR021 51309288-475 is a double-wide redundancy module designed for the Experion Chassis Series-A (CIOM-A) platform to support C200 control processor redundancy configurations. Operating within Experion LS and Experion PKS process control architectures, the TK-PRR021 facilitates synchronized, fault-tolerant operation between dual controller chassis.

Equipped with factory-applied conformal coating, Honeywell TK-PRR021 provides corrosion protection in environments rated Moderate (G2) or Harsh (G3) per ANSI/ISA-S71.04-1985 standards. The module occupies two chassis slot positions and draws power directly from internal backplane voltage rails to maintain continuous high availability in industrial process applications.

Features

  • Conformal coating protection for harsh industrial environments with airborne contaminants

  • Double-wide form factor occupying two chassis slot positions

  • Direct backplane integration for C200 control processor redundancy support

  • Low-power internal backplane draw across 24 VDC, 5 VDC, 3.3 VDC, and 1.2 VDC rails

Applications

  • High-availability DCS and PLC control loops

  • Redundant C200 control processor systems in Experion PKS and Experion LS platforms

  • Process automation environments exposed to corrosive atmospheres

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model Number TK-PRR021
Part / Assembly Number 51309288-475
Module Type Redundancy Module (RM)
Product Series Experion Chassis Series-A (CIOM-A)
Chassis Slots Required 2 (Double-wide form factor)
Conformal Coating Yes (TK designation)
Backplane Current Draw (24 VDC) 0.090 A
Backplane Current Draw (5 VDC) 1.000 A
Backplane Current Draw (3.3 VDC) 0.750 A
Backplane Current Draw (1.2 VDC) 0.007 A
Operating Temperature 0 to 60 degC
Storage Temperature -40 to 85 degC
Relative Humidity 5 to 95% noncondensing (derated to 55% above 40 degC)
Altitude Range -300 to +3000 m
Vibration (Operating/Storage) 10 to 60 Hz, 0.5 g max
Vibration (Transportation) 10 to 60 Hz, 1.0 g max
Mechanical Shock (Operating/Storage) 5 g max, 30 ms max duration
Mechanical Shock (Transportation) 20 g max, 30 ms max duration

Installation Guidelines

  • Chassis Mounting: Insert the module into two adjacent chassis slot positions in a compatible Series-A chassis (4, 7, 10, 13, or 17-slot chassis). Ensure total backplane power limits are maintained.

  • Cabinet Clearance: Maintain a minimum vertical distance of 15.2 cm (6.0 in) and horizontal distance of 10.2 cm (4.0 in) between chassis and enclosure walls for heat dissipation.

  • Removal and Insertion Under Power (RIUP): Permitted only when installed in ordinary, non-hazardous locations. RIUP is strictly prohibited in Class I, Division 2 hazardous locations without a hot work permit.

  • Environmental Protection: Enclose the assembly within a NEMA 4 or NEMA 12 panel when required by local codes or operational standards.

Compliance and Certifications

  • UL: UL 508 Industrial Control Equipment Listed

  • CSA: Class I, Division 2, Groups A, B, C & D Hazardous and Ordinary Locations

  • FM: Approved for Class I, Division 2 Hazardous Locations

  • CE Mark: Complies with EMC Directive 89/336/EEC, EN 50081-2 (Emissions), and EN 50082-2 (Immunity)

  • C-Tick: Meets Australian Radiocommunications Act 1992 Section 182 EMC requirements

Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell TK-PRR021 51309288-475 Experion Series A Redundancy Module

How many chassis slots does the redundancy module occupy?

The module uses two adjacent chassis slot positions within an Experion Series-A chassis assembly.

What protection does the conformal coating provide?

The TK designation indicates conformal coating application, which protects internal circuit components from corrosion in G2 moderate and G3 harsh airborne contaminant environments.

Is hot swapping allowed for this device?

Removal and insertion under power is permitted in ordinary, non-hazardous locations. It is not permitted in Class I, Division 2 hazardous locations without appropriate hot work procedures.

Which control processor works with this redundancy module?

The module is designed specifically to support redundancy for C200 control processors in Experion chassis systems.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...