Lenze

Lenze E84AYCPMV 8400-series PROFIBUS Communication Module

SKU E84AYCPMV

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Lenze

  • Product No.: E84AYCPMV

  • Country of origin:Germany

  • Product Type: Variable frequency drives

  • Barcode: 85044095

  • Payment: T/T, Western Union

  • Weight: 100g

  • Dimensions: 7,00cm x 10,20cm x 5,10cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The E84AYCPMV (E84AYCPMV) is a dedicated PROFIBUS DP communication module engineered for seamless integration with the Lenze 8400-series Variable Frequency Drive (VFD) ecosystem. Designed for high-performance motion control environments, this module facilitates real-time data exchange in critical industrial sectors, including automotive assembly lines, material handling, and high-precision manufacturing. By providing a stable, high-speed fieldbus interface, the E84AYCPMV minimizes latency in complex control loops, significantly reducing unplanned downtime and enhancing overall system synchronization. Its robust architecture ensures reliable performance in demanding plant floor conditions, serving as a vital link between the drive and the central PLC or supervisory control system.

Technical Configuration

The E84AYCPMV functions as a slave node within a PROFIBUS DP network, enabling the 8400-series drives to be fully integrated into larger automation architectures. The hardware is designed for direct mounting onto the inverter's communication slot, ensuring a compact footprint without requiring additional cabling. Key features include support for standard PROFIBUS baud rates up to 12 Mbit/s, automatic baud rate detection, and comprehensive diagnostic capabilities via the VFD's management software. The module employs advanced galvanic isolation to protect against electrical noise, ensuring data integrity even in environments with significant electromagnetic interference from high-power motors.

Technical Specifications

Feature Specification
Model E84AYCPMV
Brand Lenze
Series 8400-series
Origin Germany
Communication Protocol PROFIBUS DP
Weight 0.10 kg
Dimensions 7.00 cm x 10.20 cm x 5.10 cm
Operating Temperature 0 deg C to 55 deg C
Mounting Type Plug-in module for 8400-series drives

FAQs

Does the E84AYCPMV require external power for communication?

No, the module is powered directly via the internal bus connection of the host Lenze 8400-series drive, simplifying the physical installation process.

Can this module be used for safety-related communications?

The E84AYCPMV is designed for standard process and control data exchange. For safety-related functions (PROFIsafe), please refer to specific safety modules compatible with your drive version.

Is this module compatible with older 8400-series firmware versions?

Compatibility is dependent on the drive's firmware. We recommend ensuring your drive's firmware is updated to the latest revision to ensure full parameter accessibility and stable bus communication.

What is the maximum cable length for the PROFIBUS segment connected to this module?

The maximum cable length depends on the baud rate chosen for the network. At 1.5 Mbit/s, segments up to 200 meters are standard; at lower baud rates, distances can be extended per PROFIBUS specifications.

Installation Guidelines and Best Practices

  • Bus Termination: Always ensure that the PROFIBUS segment is properly terminated at both physical ends using a 220 Ohm resistor. Failure to terminate the line correctly is the most common cause of intermittent communication errors and CRC faults.

  • Shielding and Grounding: Use high-quality shielded PROFIBUS cable. The cable shield must be connected to the functional earth (FE) of the control cabinet at the entry point to mitigate high-frequency noise. Avoid running communication cables in the same conduit or tray as motor power cables to prevent cross-talk.

  • Environmental Handling: While the module is rated for industrial environments, ensure it is protected from direct moisture and conductive dust. In high-vibration applications, verify that the module is fully seated and the retention clip is engaged to prevent the connector pins from vibrating loose over time.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 5
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
White
Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...