Mitsubishi Electric

Mitsubishi Electric FX5U-64MR/DS MELSEC iQ-F Series CPU Module

SKU FX5U-64MR/DS

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Mitsubishi Electric

  • Product No.: FX5U-64MR/DS

  • Country of origin:United States

  • Product Type: PLC CPU Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Tasked with executing high-speed control logic and system coordination, the Mitsubishi Electric FX5U-64MR/DS functions as a core processing unit within the MELSEC iQ-F series platform. This controller integrates processing power, integrated communication interfaces, and localized high-density I/O handling on a single compact chassis. Equipped with 64 built-in physical I/O points, the unit utilizes a 24V DC power supply to run its internal CPU architecture and supply auxiliary power to localized extension modules. The robust screw terminal block interface ensures dependable, vibration-resistant terminations in challenging industrial operating environments.

Features

  • High-Density Control: 64 integrated I/O points comprising 32 digital inputs and 32 digital outputs.
  • DC Power Input: Tailored for standard 24 V DC control cabinets, reducing safety footprint compared to AC-powered equivalents.
  • Relay Switching Outputs: Independent mechanical relay contacts provide high electrical isolation and load tolerance across DC or AC ranges.
  • Robust Field Terminals: Hardwired screw connection terminals guarantee long-term physical stability in high-vibration machinery.
  • Dynamic Power Supply Management: Delivers internal bus power of 1100 mA at 5 V DC and 740 mA at 24 V DC to drive downstream expansion hardware.

Applications

  • Packaging and Wrapping Systems: High-speed indexing, sealing, and material feeding logic.
  • Material Handling and Conveyors: Multi-zone sortation, diverter routing, and safety interlocking.
  • Water Treatment Plant Systems: Localized pumping control, valve modulation, and level sensing.
  • Industrial HVAC Panels: Compressor sequencing, fan speed profiling, and localized system monitoring.

Technical Specifications Table

Parameter Value / Specification
Manufacturer Mitsubishi Electric
Model Number FX5U-64MR/DS
Series Name MELSEC iQ-F Series
Input Power Supply 24 V DC (+20%, -15%)
Total Built-In I/O Points 64 Points
Digital Input Specifications 32 Points, 24 V DC (Sink type)
Digital Output Specifications 32 Points, Relay outputs
5 V DC Internal Supply Capacity 1100 mA
24 V DC Internal Supply Capacity 740 mA
Termination Interface Screw terminal block
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Terminal / Port Functional Assignment / Description
L+ / M Main DC power supply input terminals (24 V DC)
Functional Ground (FG) System noise filtration and grounding reference point
X0 to X37 24 V DC Sink digital input terminals
Y0 to Y37 Mechanical relay switching contact output terminals

Empirical Engineering Insights

Alternative Models & Compatibility

Migrating old architectures from FX3U to the FX5U platform requires standard program migration through GX Works3 software. Be aware that the FX5U-64MR/DS is a 24 V DC input model; do not substitute or confuse this model code with the AC line-powered alternative (FX5U-64MR/ES), as their wiring schemas and internal grounding configurations differ significantly.

Application Pitfalls & Engineering Notes

To protect the mechanical relay contacts in the FX5U-64MR/DS when driving inductive loads like solenoids or contactors, you must install external surge-suppression devices. Use an RC snubber network across AC inductive loads, and a freewheeling diode across DC inductive loads to prevent premature point-welding of internal relays.

Commissioning & Wiring Tips

When routing communication cables and wiring the DC inputs, ensure that all logic signals are physically isolated from high-voltage motor conductors. Use class-D grounding (100 ohms or less) dedicated solely to the PLC system to minimize electromagnetic interference on the internal CPU bus and high-speed counter registers.

Installation Guidelines

CRITICAL WARNING: Verify complete physical de-energization of the distribution panel before commencing installation or removal of the module. Failure to isolate power from the main and auxiliary inputs can cause catastrophic electrical shock or permanently destroy the internal CPU logic circuits.
1

Mount the CPU module securely on a standard 35mm DIN rail or utilize direct screw mounting in an enclosed, low-vibration control panel environment.

2

Connect the dedicated functional ground (FG) terminal to the common protective ground busbar before finishing auxiliary wiring.

3

Wire the 24V DC supply cables directly to the L+ and M terminals, verifying correct polarity with a standard digital multimeter prior to initial system power-up.

FAQ

What power supply voltage is required for the FX5U-64MR/DS CPU module?

This module operates on a nominal input power supply of 24 V DC (operational range of +20% to -15%).

What are the characteristics of the inputs and outputs on this unit?

It features 32 inputs rated for 24 V DC (sink type) and 32 digital outputs driven by mechanical relays.

What is the internal power capacity provided for downstream expansion modules?

The module supplies up to 1100 mA at 5 V DC and 740 mA at 24 V DC to power connected expansion and communication modules.

Does this module use screw or spring terminals?

The FX5U-64MR/DS utilizes a robust screw terminal block interface for all field wiring terminations.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.