Mitsubishi Electric

Mitsubishi Electric Q02CPU MELSEC Q Series PLC CPU Module

SKU Q02CPU

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Mitsubishi Electric

  • Product No.: Q02CPU

  • Country of origin:United States

  • Product Type: PLC CPU Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 120 mm x 110 mm x 45 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Designed for centralized control in mid-scale automation architectures, the Mitsubishi Electric Q02CPU functions as a high-performance programmable logic controller processor within the MELSEC Q Series family. This module coordinates sequence control and device data processing with an optimized instruction set, supporting highly stable operations across manufacturing lines. Featuring a compact modular footprint, it integrates directly into standard Q Series base units, enabling seamless expansion and communication with specialized I/O and network modules.

Features

  • High-Speed Processing: Basic instruction processing speed of 0.079 us (microseconds) per LD instruction for rapid program execution.
  • Optimized Program Memory: 28 k steps program capacity with 112 KB of internal program memory.
  • Broad I/O Capabilities: Supports up to 4096 local and remote I/O points, alongside 8192 direct device points.
  • Flexible Storage Options: Built-in slot for memory cards (SRAM, Flash, or ATA) to easily manage recipe data, logging, and program backups.
  • Integrated Communication: Built-in RS-232 interface for direct connection to programming PCs, HMIs, and serial devices.

Applications

  • Automated Assembly Lines: Handles coordinated sequence control for multi-station assembly systems.
  • Material Handling Systems: Manages complex conveyor networks, sorters, and transfer systems.
  • Packaging and Food Processing: Drives packaging lines requiring fast processing of sensor signals and precise actuator outputs.
  • Utility and Water Treatment: Serves as the central PLC for localized pump stations and filtration systems.

Technical Specifications

Parameter Value
Manufacturer Mitsubishi Electric
Model Number Q02CPU
Series MELSEC Q Series
Program Capacity 28 k steps
Program Memory 112 KB
LD Instruction Execution Speed 0.079 us
I/O Points 4096 points (local/remote)
I/O Device Points 8192 points
Internal Current Consumption (5V DC) 0.60 A
Operating Temperature Range 0 to 55 degC
Shipping Weight (Calculated) 0.30 kg
Package Dimensions (Calculated) 120 mm x 110 mm x 45 mm

Connections and Interfaces

Connector / Port Interface Type Function Assignment
Built-in Serial Port RS-232 (Mini-DIN 6-Pin) Programming, debugging, and direct HMI connection
Memory Card Interface PCMCIA-compliant slot External memory card installation (SRAM/Flash/ATA)

Empirical Engineering Insights

Alternative Models & Compatibility

The Q02CPU is a legacy standard model within the MELSEC Q series. For systems requiring faster processing speeds, integrated Ethernet connectivity, or expanded data logging, consider the Q03UDVCPU or Q04UDVCPU. When swapping to a Universal Q Series CPU, verify program parameters in GX Works2 as some specialized instruction behaviors and memory card formats vary between the classic Q02CPU and newer "Universal" (UD/UDV) modules.

Application Pitfalls & Engineering Notes

The Q02CPU has a strict program limit of 28 k steps. Exceeding this limit will trigger compilation failures. When utilizing extensive file registers (ZR), ensure you allocate the memory blocks correctly in the PLC parameters before downloading. If the battery voltage drops, stored latch data and SRAM contents will be lost; always establish a periodic preventative maintenance schedule to replace the Q6BAT backup battery.

Commissioning & Wiring Tips

When connecting to the RS-232 port with a QC30R2 programming cable or third-party serial-to-USB converters, ensure the communications parameters in GX Works2/GX Developer match (baud rate, parity, stop bits). To prevent serial communication dropouts caused by high-frequency electromagnetic interference (EMI) from neighboring variable frequency drives (VFDs), ensure the base unit’s functional ground (FG) terminal is grounded directly to a low-impedance earth point.

Installation Guidelines

CRITICAL WARNING:

Isolate and completely lock out the main power supply feeding the MELSEC Q base unit before mounting or removing the CPU module. Hot-swapping the CPU module is strictly prohibited and will result in irreversible hardware damage or unpredictable system behavior.

1
Align the lower hook of the Q02CPU into the guide hole on the main base unit (e.g., Q33B, Q35B, Q38B).
2
Push the module firmly into place against the base unit connector, ensuring there is no gap.
3
Secure the module by tightening the top retention screw (torque to 0.36 to 0.48 N-m) to prevent vibration-induced disconnection.
4
Connect the programming or communication cable to the built-in RS-232 port, applying adequate strain relief.

FAQ

What programming software should be used to configure the Q02CPU?

The module is programmed using either GX Developer or GX Works2. In your software project settings, select 'QCPU (Q mode)' as the PLC type and designate the specific 'Q02' processor type.

Can this CPU be connected directly to an Ethernet network?

No. The unit only has a built-in RS-232 serial interface. For Ethernet communications, you must install an Ethernet module, such as the QJ71E71-100, on the base unit, or upgrade to a Universal Q CPU with a built-in Ethernet port (e.g., Q03UDECPU).

How do you handle the battery replacement without losing the stored PLC program?

Ensure the PLC remains powered on for at least ten minutes before replacing the Q6BAT battery. Turn off the power and complete the physical battery replacement within three minutes to prevent memory loss from the backup capacitor.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.