1 of 1

Schneider Altivar VW3A3310 Ethernet Modbus TCP Communication Module

Schneider Altivar VW3A3310 Ethernet Modbus TCP Communication Module

Only 9 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: VW3A3310

  • Country of origin:France

  • Product Type: CoMMunication Modules

  • Payment: T/T, Western Union

  • Weight: 400g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The VW3A3310 is an Ethernet Modbus TCP communication module designed for use with Schneider Electric Altivar series drives. This module provides connectivity to Ethernet-based industrial networks, allowing for the transmission of data and real-time monitoring via the Modbus TCP protocol. The VW3A3310 acts as a bridge between the drive and the wider automation architecture, enabling efficient control, diagnostics, and integration into existing industrial Ethernet infrastructures.

Features

  • Ethernet Modbus TCP protocol support
  • Enables real-time drive monitoring and control
  • Seamless integration with Altivar series drive communication slots
  • Supports robust data transfer in industrial environments
  • Compact design for internal drive integration

Applications

  • Industrial automation network integration
  • Remote drive monitoring and diagnostics
  • Data acquisition for SCADA systems
  • PLC-to-drive communication over Ethernet

Technical Specifications

Specification Details
Manufacturer Schneider Electric
Range Altivar
Product Type Communication module
Protocol Ethernet Modbus TCP
Weight 0.40 kg
Commodity Code 85371091
Product Status Phase-Out

Installation Guidelines

  • Integration: Power down the drive completely before inserting the VW3A3310 module into the designated communication expansion slot.
  • Mounting: Ensure the module is fully seated and secured according to the drive’s mechanical specifications to prevent disconnection due to vibration.
  • Cabling: Use shielded Cat5e or Cat6 industrial Ethernet cables to connect to the network port to minimize signal interference.
  • Configuration: After physical installation, configure the drive’s communication parameters via the human-machine interface (HMI) or software tool to assign a valid IP address and operational settings.
  • Environment: Maintain the communication module within the specified operating temperature and humidity limits of the host drive to ensure reliable network uptime.

What protocol does the VW3A3310 module support?

This module supports the Ethernet Modbus TCP communication protocol.

Which product range is the VW3A3310 compatible with?

It is designed for use within the Schneider Electric Altivar drive range.

What is the primary function of this module?

The module enables communication between the drive and an Ethernet network, facilitating control, monitoring, and diagnostics.

What is the lifecycle status of the VW3A3310?

The VW3A3310 module is currently classified in the Phase-Out lifecycle stage.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
France

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...