Schneider Electric

Schneider Electric Modicon Quantum 140CPS11420 AC Power Supply Module

SKU 140CPS11420

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Schneider Electric
  • Product No.: 140CPS11420
  • Origin France
  • Product Type: Power Supply Modules
  • Payment: T/T, Western Union
  • Weight: 0.65 kg
  • Dimensions: 44.9 x 290 x 163 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Schneider Electric Modicon Quantum 140CPS11420 AC Power Supply Module

Quantity

Product Description

Description

The Schneider Electric Modicon Quantum 140CPS11420 is a summable or standalone AC power supply module designed to deliver regulated power to backplane components within the Modicon Quantum automation platform. Operating on nominal input voltages of 115 VAC or 230 VAC, the unit converts main power sources into a stable 5.1 VDC output, delivering up to 11 A in standalone mode or up to 20 A when used in a summable configuration at 60 degC.

Engineered to support system reliability, the 140CPS11420 integrates internal overvoltage and overload protection mechanisms alongside a dedicated power-loss alarm relay output (1 NC contact rated for 220 VAC at 6 A / 30 VDC at 5 A). Front-panel diagnostic reporting is provided via a green PWR OK LED. Grounded within standard Quantum backplane racks, the module provides stable internal current distribution for installed CPUs, communication modules, and I/O slices.

Features

  • Flexible operational modes allowing standalone (11 A) or summable (up to 20 A) power expansion.
  • Dual AC input voltage support for 115 VAC (93...132 VAC) and 230 VAC (170...276 VAC) lines.
  • Integrated internal overvoltage and overload protective circuitry to protect internal system components.
  • Hardwired power-loss alarm output featuring a normally closed (NC) dry relay contact set.
  • Clear local diagnostic feedback via a dedicated green PWR OK panel LED indicator.
  • Standard Modicon Quantum backplane form factor for standard rack installation.

Applications

  • Primary backplane power distribution for Modicon Quantum PLC rack configurations.
  • Summable power architecture in high-density, multi-module I/O racks requiring current beyond 11 A.
  • System monitoring interfaces utilizing the fault relay output for external mains loss reporting.

Technical Specifications

Parameter Specification
Manufacturer Schneider Electric
Range of Product Modicon Quantum automation platform
Product / Component Type Power supply module
Power Supply Type Summable or standalone
Input Voltage 115 VAC (93...132 VAC, 47...63 Hz) / 230 VAC (170...276 VAC, 47...63 Hz)
Input Current 1300 mA at 115 V / 750 mA at 230 V
Inrush Current 19 A at 230 V / 38 A at 115 V
Rated Power 130 VA
Output Voltage 5.1 V DC
Power Supply Output Current 11 A at 60 degC (Standalone) / 20 A at 60 degC (Summable)
Harmonic Distortion <= 10 % of fundamental rms value
Associated Fuse Rating 2 A, slow-blow (Modicon 57-00089-000 or equivalent)
Power Dissipation 6 + (1.5 x Iout) where Iout is in A
Alarm Output 1 NC relay (6 A at 220 VAC / 5 A at 30 VDC power supply fault)
Output Protection Internal overvoltage and output overload protection
Local Signalling 1 green LED (PWR OK)
Module Format Standard Quantum rack mount
Product Weight 0.65 kg (1.43 lb)
Ambient Air Temperature for Operation 0...60 degC (32...140 degF)
Ambient Air Temperature for Storage -40...85 degC (-40...185 degF)
Relative Humidity 95 % non-condensing
Operating Altitude <= 5000 m (16404.2 ft)

Connections / Interfaces

Terminal Pin Function
1 Power Loss Alarm Relay Output (NC)
2 Power Loss Alarm Relay Output (NC)
3 Voltage Selection Jumper Terminal (Install jumper for 115 VAC only)
4 Voltage Selection Jumper Terminal (Install jumper for 115 VAC only)
5 AC Line Input (AC L)
6 AC Neutral Input (AC N)
7 Protective Earth Ground

Installation Guidelines

  1. Verify that the system main power is disconnected prior to inserting or removing the power supply from the Quantum backplane.
  2. Confirm input line voltage settings; ensure terminal pins 3 and 4 have a jumper installed for 115 VAC operation, or leave open for 230 VAC operation.
  3. Align the module with the dedicated slot in the Quantum rack and seat it firmly into the backplane connector.
  4. Wire the AC mains supply to terminal 5 (AC L) and terminal 6 (AC N), and attach the protective grounding line to terminal 7.
  5. If auxiliary monitoring is required, wire external alarm loops through the NC dry relay contacts on terminals 1 and 2.
  6. Verify that an external 2.0 A slow-blow fuse is installed in the line circuit prior to energizing the module.

Configuration / Commissioning / Replacement Recommendations

  • Summable Operation Compatibility: Combine only approved AC summable power supply models (such as 140CPS11420 or 140CPS11410) within the same backplane rack. Do not mix AC power supplies with DC models (e.g., 214 00 or 414 00) in summable configurations.
  • Software Power Calculations: Note that legacy programming software (such as ProWORX NxT versions prior to v2.2 SR8) may calculate power consumption incorrectly for 11 A modules. Calculate backplane power totals manually when configuring racks in legacy software environments.
  • Replacement Procedure: When replacing a failed module, power down the rack feed, disconnect the 7-point terminal connector, release the top/bottom rack seating levers, replace the hardware, and reconnect the terminal block without altering cabinet field wiring.

Compliance and Certifications

Certification / Standard Rating / Compliance Details
Standards UL 508, CSA C22.2 No 142
Markings / Product Certifications CE, cUL
Electrostatic Discharge Resistance 4 kV contact / 8 kV air conforming to IEC 801-2
Electromagnetic Field Resistance 9.1 V/m (10 V/m) 80...2000 MHz conforming to IEC 801-3
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Schneider Electric Modicon Quantum 140CPS11420?
The Schneider Electric Modicon Quantum 140CPS11420 is an AC power supply module that converts incoming 115 VAC or 230 VAC supply power to 5.1 VDC to provide internal operating power to modules residing on a Modicon Quantum PLC backplane rack.
What output current can the 140CPS11420 module supply?
The module provides up to 11 A at 5.1 VDC when used in standalone mode at 60 degC. When configured with another compatible summable power module in the same rack, total available backplane output current increases to 20 A.
How do you select between 115 VAC and 230 VAC input operation on the 140CPS11420?
Voltage selection is set at the 7-point front terminal connector. A jumper wire must be installed between terminal pins 3 and 4 for 115 VAC input operation, whereas these pins are left unconnected for 230 VAC operation.
Can the 140CPS11420 AC power supply be paralleled with DC power supply modules?
No, according to Schneider Electric compatibility matrices, AC power supply modules like the 140CPS11420 can only be paired with compatible AC summable models (such as the 140CPS11410). Combining AC and DC power modules in a summable configuration is prohibited.
Reviews

140CPS11420

Stock &amp; lead time on request

Call
1 of 6

Schneider Electric Modicon Quantum 140CPS11420 AC Power Supply Module

Only 9 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: 140CPS11420

  • Country of origin:France

  • Product Type: Power Supply Modules

  • Payment: T/T, Western Union

  • Weight: 650g

  • Dimensions: 44.9 x 290 x 163 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Schneider Electric Modicon Quantum 140CPS11420 is a summable or standalone AC power supply module designed to deliver regulated power to backplane components within the Modicon Quantum automation platform. Operating on nominal input voltages of 115 VAC or 230 VAC, the unit converts main power sources into a stable 5.1 VDC output, delivering up to 11 A in standalone mode or up to 20 A when used in a summable configuration at 60 degC.

Engineered to support system reliability, the 140CPS11420 integrates internal overvoltage and overload protection mechanisms alongside a dedicated power-loss alarm relay output (1 NC contact rated for 220 VAC at 6 A / 30 VDC at 5 A). Front-panel diagnostic reporting is provided via a green PWR OK LED. Grounded within standard Quantum backplane racks, the module provides stable internal current distribution for installed CPUs, communication modules, and I/O slices.

Features

  • Flexible operational modes allowing standalone (11 A) or summable (up to 20 A) power expansion.
  • Dual AC input voltage support for 115 VAC (93...132 VAC) and 230 VAC (170...276 VAC) lines.
  • Integrated internal overvoltage and overload protective circuitry to protect internal system components.
  • Hardwired power-loss alarm output featuring a normally closed (NC) dry relay contact set.
  • Clear local diagnostic feedback via a dedicated green PWR OK panel LED indicator.
  • Standard Modicon Quantum backplane form factor for standard rack installation.

Applications

  • Primary backplane power distribution for Modicon Quantum PLC rack configurations.
  • Summable power architecture in high-density, multi-module I/O racks requiring current beyond 11 A.
  • System monitoring interfaces utilizing the fault relay output for external mains loss reporting.

Technical Specifications

Parameter Specification
Manufacturer Schneider Electric
Range of Product Modicon Quantum automation platform
Product / Component Type Power supply module
Power Supply Type Summable or standalone
Input Voltage 115 VAC (93...132 VAC, 47...63 Hz) / 230 VAC (170...276 VAC, 47...63 Hz)
Input Current 1300 mA at 115 V / 750 mA at 230 V
Inrush Current 19 A at 230 V / 38 A at 115 V
Rated Power 130 VA
Output Voltage 5.1 V DC
Power Supply Output Current 11 A at 60 degC (Standalone) / 20 A at 60 degC (Summable)
Harmonic Distortion <= 10 % of fundamental rms value
Associated Fuse Rating 2 A, slow-blow (Modicon 57-00089-000 or equivalent)
Power Dissipation 6 + (1.5 x Iout) where Iout is in A
Alarm Output 1 NC relay (6 A at 220 VAC / 5 A at 30 VDC power supply fault)
Output Protection Internal overvoltage and output overload protection
Local Signalling 1 green LED (PWR OK)
Module Format Standard Quantum rack mount
Product Weight 0.65 kg (1.43 lb)
Ambient Air Temperature for Operation 0...60 degC (32...140 degF)
Ambient Air Temperature for Storage -40...85 degC (-40...185 degF)
Relative Humidity 95 % non-condensing
Operating Altitude <= 5000 m (16404.2 ft)

Connections / Interfaces

Terminal Pin Function
1 Power Loss Alarm Relay Output (NC)
2 Power Loss Alarm Relay Output (NC)
3 Voltage Selection Jumper Terminal (Install jumper for 115 VAC only)
4 Voltage Selection Jumper Terminal (Install jumper for 115 VAC only)
5 AC Line Input (AC L)
6 AC Neutral Input (AC N)
7 Protective Earth Ground

Installation Guidelines

  1. Verify that the system main power is disconnected prior to inserting or removing the power supply from the Quantum backplane.
  2. Confirm input line voltage settings; ensure terminal pins 3 and 4 have a jumper installed for 115 VAC operation, or leave open for 230 VAC operation.
  3. Align the module with the dedicated slot in the Quantum rack and seat it firmly into the backplane connector.
  4. Wire the AC mains supply to terminal 5 (AC L) and terminal 6 (AC N), and attach the protective grounding line to terminal 7.
  5. If auxiliary monitoring is required, wire external alarm loops through the NC dry relay contacts on terminals 1 and 2.
  6. Verify that an external 2.0 A slow-blow fuse is installed in the line circuit prior to energizing the module.

Configuration / Commissioning / Replacement Recommendations

  • Summable Operation Compatibility: Combine only approved AC summable power supply models (such as 140CPS11420 or 140CPS11410) within the same backplane rack. Do not mix AC power supplies with DC models (e.g., 214 00 or 414 00) in summable configurations.
  • Software Power Calculations: Note that legacy programming software (such as ProWORX NxT versions prior to v2.2 SR8) may calculate power consumption incorrectly for 11 A modules. Calculate backplane power totals manually when configuring racks in legacy software environments.
  • Replacement Procedure: When replacing a failed module, power down the rack feed, disconnect the 7-point terminal connector, release the top/bottom rack seating levers, replace the hardware, and reconnect the terminal block without altering cabinet field wiring.

Compliance and Certifications

Certification / Standard Rating / Compliance Details
Standards UL 508, CSA C22.2 No 142
Markings / Product Certifications CE, cUL
Electrostatic Discharge Resistance 4 kV contact / 8 kV air conforming to IEC 801-2
Electromagnetic Field Resistance 9.1 V/m (10 V/m) 80...2000 MHz conforming to IEC 801-3
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Schneider Electric Modicon Quantum 140CPS11420 AC Power Supply Module

What is the primary function of the Schneider Electric Modicon Quantum 140CPS11420?

The Schneider Electric Modicon Quantum 140CPS11420 is an AC power supply module that converts incoming 115 VAC or 230 VAC supply power to 5.1 VDC to provide internal operating power to modules residing on a Modicon Quantum PLC backplane rack.

What output current can the 140CPS11420 module supply?

The module provides up to 11 A at 5.1 VDC when used in standalone mode at 60 degC. When configured with another compatible summable power module in the same rack, total available backplane output current increases to 20 A.

How do you select between 115 VAC and 230 VAC input operation on the 140CPS11420?

Voltage selection is set at the 7-point front terminal connector. A jumper wire must be installed between terminal pins 3 and 4 for 115 VAC input operation, whereas these pins are left unconnected for 230 VAC operation.

Can the 140CPS11420 AC power supply be paralleled with DC power supply modules?

No, according to Schneider Electric compatibility matrices, AC power supply modules like the 140CPS11420 can only be paired with compatible AC summable models (such as the 140CPS11410). Combining AC and DC power modules in a summable configuration is prohibited.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Beige
Country of origin
France
Power source
AC-powered

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...